Search bioRxiv⌕ Search

bioRxiv · 10.1101/2025.02.24.639804

Effect of perchlorate on biocementation capable bacteria and Martian bricks

Abstract

With the recent discovery of perchlorate (0.5-1%) in Martian regolith, more experiments related to the impact of perchlorate on microbial life are crucial to understanding the possibility of earth life forms that could sustain on the Martian terrain. While we are familiar with the idea of bioconsolidated Martian bricks made via Microbially Induced Calcite Precipitation (MICP), studies on the effect of perchlorate on Martian bricks & biocementation capable microbes have been obscure. In this work, we investigated the effect of perchlorate (MgClO4- salt) on a lab-isolated biocementation capable bacteria & Martian bricks bioconsolidated by the same, with 1% perchlorate in Mars Global Simulant-1 (MGS-1). The screening of biocementation-capable bacteria involved phenol red assay for urease activity followed by Scanning Electron Microscopy (SEM) and X-ray diffraction (XRD) study of the precipitate formed through MICP via ureolytic pathway. The biocementation capable bacterium SI_IISc_isolate was found phylogenetically closest to Sporosarcina pasteurii strain S2135, its draft genome being approximately 3.69 Mb. To understand the effect of perchlorate on SI_IISc_isolate, we majorly relied on Gram-staining & SEM. The negative effect of perchlorate stress on the isolate was evident by its decreased growth in the presence of varying concentrations of perchlorate through plate assays, growth curve studies in broth & live-dead staining. Gram-staining study and SEM both revealed that perchlorate induces the release of extracellular matrix (ECM) and promotes clustering of cells by the bacteria, which we termed as multicellularity-like behavior. Further, we constructed Martian bricks with Martian Global Simulant (MGS-1) along with 1% perchlorate, utilizing the microbially induced calcite precipitation ability of the Sporosarcina sp. strain SI_IISc_isolate via ureolysis, following an established protocol at our lab. The bioconsolidation experiments showed that in the presence of a natural adhesive - guar gum, perchlorate tends to significantly improve the compressive strength of Martian bricks. However, the end result eventually relies on the overall effect of various additives in the regolith.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dubey, S., Shukla, S., Gupta, N., Dixit, R., Bhadury, P., Kumar, A.. 2025-02-28. Effect of perchlorate on biocementation capable bacteria and Martian bricks. https://doi.org/10.1101/2025.02.24.639804

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗