Search bioRxiv⌕ Search

bioRxiv · 10.1101/2024.09.27.615423

Differentiation Protocol-Dependent Variability in hiPSC-Derived Endothelial Progenitor Functionality

Abstract

PurposeWith multiple groups generating methods for differentiating induced pluripotent stem cells (hiPSCs) into endothelial cells/endothelial progenitors (ECs/EPs), there is a need to better understand the specific endothelial subtypes that different differentiation protocols produce. This is especially important for accurate tissue modeling as researchers continue to incorporate the endothelium into engineered tissues. MethodsWe illustrated the heterogeneity of cells produced from different differentiation protocols by focusing on two selected protocols, one driving differentiation exclusively using small molecules (SM Protocol) and one driving differentiation primarily using growth factors (GF Protocol). We characterized the cells through a combination of vasculogenic computational analysis following encapsulation in 3D hydrogels, RNA sequencing, and measurement of soluble factor release. ResultsVasculogenic computational analysis indicates that cells from the GF protocol formed more dense and interconnected vasculature compared to cells from the SM protocol. Likewise, RNA-seq analysis showed GF-derived cell enrichment in pathways involved in cell migration and angiogenesis. In addition, GF-derived cells favor differentiation to arterial endothelial cells as well as predisposition to undergoing a partial endothelial-to-mesenchymal transition, whereas SM-derived cells resemble immature progenitors based on higher proliferation rates as well as ECM remodeling. These trends also persisted following extended 3D culture. ConclusionsThe results demonstrate that despite using the same starting hiPSC population and isolating EPs using the same surface marker, the two differentiation protocols yield highly distinct cell populations. This work highlights the importance of understanding the specific endothelial subtypes produced by different differentiation protocols for the creation of more accurate tissue models. Lay SummaryAlthough multiple groups have created protocols for differentiating human induced pluripotent stem cells (hiPSCs) to endothelial progenitors (EPs), it is not clear if different differentiation protocols generate different endothelial subtypes, matching the variance seen in vivo To that end, we performed an in-depth characterization of two selected hiPSC-EP differentiation protocols, primarily focusing on cells cultured in 3D hydrogels, to better understand the specific endothelial subtypes produced. We found significant differences in both cell maturity and cell phenotype that persisted even after extended culture. Future WorkFuture work will involve extending the existing study to include additional hiPSC-EP differentiation protocols as well as conducting single-cell RNAseq to better understand the makeup of different cell populations both before and after isolating CD34+ cells. Because smooth muscle cells play an important role in vessel stabilization, we will also incorporate hiPSC-derived smooth muscle cells into the system.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stern, B., Meng, S., Larsen, B., Brock, A., Zoldan, J.. 2024-09-30. Differentiation Protocol-Dependent Variability in hiPSC-Derived Endothelial Progenitor Functionality. https://doi.org/10.1101/2024.09.27.615423

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗