Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework

Abstract

Aortic stenosis (AS) leads to alterations of supra-valvular flow patterns. These patterns might lead to, inter alia, increased damage of red blood cell (RBC) membranes. We investigated these patient specific patterns of a severe AS patient and their reversal in healthy flow through a 4D Flow MRI-based CFD methodology. Computational models of subject-specific aortic geometries were created using in-vivo medical imaging data. Temporally and spatially resolved boundary conditions derived from 4D Flow MRI were implemented for an AS patient and a healthy subject. After validation of the in-silico results with in-vivo data, a healthy inflow profile was set for the AS patient in the CFD model. Pathological versus healthy flow fields were compared regarding their blood flow characteristics, i.e. shear stresses on RBCs and helicity. The accuracy of the 4D Flow MRI-based CFD model was proven with excellent agreement between in-vivo and in-silico velocity fields and R{superscript 2} = 0.9. A pathological high shear stress region in the bulk flow was present during late systole with an increase of 125 % compared to both healthy flow. The physiological bihelical structure with predominantly right-handed helices vanished for the pathological state. Instead, a left-handed helix appeared, accompanied by an overall increase in turbulent kinetic energy in areas of accumulated left-handed helicity. The validated 4D Flow MRI-based CFD model identified marked differences between AS and healthy flow. It suggests that altered turbulent and helical structures in the bulk flow are the cause for increased, potentially damaging forces acting upon RBCs in AS. Author SummaryAortic stenosis (AS) is a condition that alters the flow of blood through the aorta, potentially increasing damage to red blood cells (RBCs). It is therefore crucial to understand the precise nature of these changes, especially in the bulk region where the RBCs are mainly circulating. To investigate this, we developed a computational model based on patient-specific 4D Flow MRI data to simulate blood flow in a patient with severe AS and a healthy individual. Our high-fidelity models show high agreement with real-world data. We then imposed synthetically generated healthy flow conditions in the AS patient to eliminate age- and geometry-related uncertainties. Our results revealed significantly higher shear stresses and changes in helical flow patterns in the AS patient compared to healthy flow, suggesting that these alterations could increase the risk of RBC membrane damage. These findings underscore the importance of deepening our understanding about the interplay between bulk flow alterations and their impact on RBCs, as previous studies were mostly focused on near wall regions. This methodology could also be extended to other cardiovascular conditions, aiding in the development of patient-specific treatment strategies.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wang, T., Quast, C., Bönner, F., Kelm, M., Zeus, T., Lemainque, T., Steinseifer, U., Neidlin, M.. 2024-09-10. Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework. https://doi.org/10.1101/2024.09.09.611958

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Single-Component Photo-Crosslinked Lipoic Acid Functionalized Mucin Hydrogels: Dynamic Mucus Mimetics for Antiviral Protection

Native mucus protects epithelial surfaces through viscoelastic networks of disulfide-linked mucins. However, commercially available mucins often fail to reconstitute comparable mechanical and barrier properties, while synthetic and hybrid mucus mimetics require polymeric crosslinkers that may alter mucus-like composition. Inspired by the native architecture, we directly functionalized porcine gastric and bovine submaxillary mucins with -lipoic acid to develop a single-component, photo-crosslinkable hydrogels. Upon UV irradiation (365 nm), the modified mucins rapidly form disulfide-crosslinked networks without added photo-initiator/ polymeric crosslinkers, two orders of magnitude faster as compared with PEG-SH approaches. The resulting mucin-lipoic acid (MUC-LA) hydrogels exhibit mucus-relevant properties, including tunable viscoelasticity, redox responsiveness, self-healing, and size-dependent restrictions on nanoparticle transport. In transwell-based infection models, MUC-LA hydrogels (2-3%) mimicking the healthy airway mucus (G' {approx} 10-20 Pa) suppress epithelial infection by SARS-CoV-2 and influenza A virus. Crosslinked MUC-LA provides greater protection against SARS-CoV-2 than the non-crosslinked, whereas both formulations suppress influenza A infection, suggesting distinct contributions from network formation and mucin-associated interactions. These findings establish a dynamic, mucus-mimetic platform integrating rapid photo-gelation, controllable mechanics, selective transport, and antiviral barrier functionality. MUC-LA hydrogels offer opportunities to investigate mucosal transport and host-pathogen interactions, with potential applications in drug delivery, and as biomaterials.

bioengineering↗

Population-level emulation enables fast Bayesian calibration of cardiac digital twins

Purpose: Patient-specific cardiac digital twins have the potential to guide individualized therapy, but generating these in a routine clinical workflow remains challenging. This is especially true when the twins must carry quantified uncertainty: Bayesian calibration requires thousands of simulations per patient, and the emulators that reduce this cost are typically trained one patient at a time. We aimed to train a single emulator across a patient cohort, so that a new patient can be calibrated in minutes without new simulations. Methods: We trained a population-level Gaussian process emulator whose inputs included a 12-dimensional latent encoding of the clinical features of each patient, so that a single emulator represents the whole cohort. We compared spending simulation budgets on resampling the real cohort with augmenting the cohort with digital chimeras, synthetic patients interpolated between real patients. Seven parameters of a closed-loop heart and circulation model were calibrated by Markov chain Monte Carlo to ten clinical biomarkers in 26 patients with left bundle branch block, each using an emulator trained without that patient, and the calibrated posteriors were compared against the full simulator. Results: A single emulator, trained without the held-out patient, calibrated the digital twin of each patient in 59.7-63.0 s per patient, versus 15 h with the simulator. Resampling the real cohort was the more efficient training strategy, bringing every output to R2 greater than or equal to 0.9, which augmentation did not achieve for the same simulation budget. For held-out patients, both strategies performed comparably (median leave-one-out normalized root-mean-square error 11.0% vs. 10.7%; p = 0.745), and error rose with distance from the cohort centroid (Spearman rho = +0.406). The calibrated models showed no cohort-wide bias (median standardized residual -0.12 against the clinical targets), and 95% predictive intervals contained 78.5% of targets, with the largest misfit in systolic blood pressure. Conclusion: Removing the need for new simulations for every new patient is a meaningful step toward uncertainty-aware cardiac digital twins that fit within a routine clinical workflow. Because the simulator, surrogate and sampler are interchangeable, the approach used here can be applied to other (cardiac) models and cohorts.

bioengineering↗

Multi-Structure Segmentation of Type B Aortic Dissection from CT Images with U-Net

Type B aortic dissection (TBAD) is a life-threatening condition in which a tear in the intimal layer separates the aortic wall into a true and a false lumen. Assessment of the lumen, the intimal flap, and false-lumen thrombosis from CT images is important for risk analysis and treatment planning. This work applied U-Net-based deep neural networks to the automatic segmentation of these structures in TBAD. We collected 46 CT scans from 20 patients, with voxel-wise annotations of three structures: the aortic lumen, the intimal flap, and the thrombus. We explored four models: two convolutional networks, nnU-Net 2D and 3D, and two transformer-based architectures, TransUNet 2D and 3D. We observed that (1) for both nnU-Net and TransUNet, the 3D models outperformed their 2D counterparts on all three structures. The difference was small for the aortic lumen but large for the thin flap and the thrombus. The best model, nnU-Net 3D, reached a DSC of 93.05% for the lumen, 50.22% for the flap, and 69.94% for the thrombus. (2) The intimal flap was the most difficult structure for all models. Even the best 3D models showed large thrombus boundary errors in a few scans. These results provide a baseline for developing more advanced models for accurate segmentation of these structures in TBAD.

bioengineering↗