Search bioRxiv⌕ Search

bioRxiv · 10.1101/2024.06.05.597616

An Infusible Extracellular Matrix Biomaterial Improves Survival in a Model of Severe Systemic Inflammation

Abstract

Excess systemic inflammation can often be lethal in septic and trauma patients due to onset of multiple organ dysfunction syndrome (MODS). As of right now, there are no effective immunomodulatory therapeutics that can promote survival within this patient population. Pro-regenerative extracellular matrix (ECM) biomaterials have shown success for treatment of local inflammation but have not been fully explored for treating systemic inflammation. Here, we demonstrate efficacy of an intravenously delivered infusible ECM (iECM) material, which promotes increased survival in a murine model of MODS by decreasing systemic mediators of inflammation. Lung and kidney failure are associated with higher mortality in MODS compared to other organ failures, and we demonstrate that iECM localizes primarily to kidney and lung tissues during systemic inflammation induced by endotoxin. iECM successfully lowered vascular permeability within lung tissue and lowered levels of inflammatory cytokine signaling such as IL-6, verified via ELISA and gene expression analyses. We also demonstrated that immune cell infiltration into lung tissue was modulated with iECM treatment, with an increase in neutrophil retention in the lung and decreases in pro-inflammatory macrophage presence. In summation, iECM improves survival from severe systemic inflammation by decreasing the local and systemic inflammatory signaling pathways that contribute to MODS. These results provide a strong rationale for translational studies of iECM treatment in systemic inflammatory syndromes, including sepsis and trauma.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Karkanitsa, M. L., Wang, R., Lyons, A. C., Mesfin, J. M., Chen, A., Spang, M. T., Quintero, F., Sadtler, K., Christman, K. L.. 2024-06-06. An Infusible Extracellular Matrix Biomaterial Improves Survival in a Model of Severe Systemic Inflammation. https://doi.org/10.1101/2024.06.05.597616

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗