Abstract

BackgroundAlthough transcranial magnetic stimulation (TMS) is the optimal tool for identifying individual motor hotspots for transcranial electrical stimulation (tES), it requires a cumbersome procedure in which patients must visit the hospital each time and rely on expert judgment to determine the motor hotspot. Therefore, in previous study, we proposed electroencephalography (EEG)-based machine learning approach to automatically identify individual motor hotspots. In this study, we proposed an advanced EEG-based motor hotspot identification algorithm using a deep learning model and assessed its clinical feasibility and benefits by applying it to stroke patient EEGs. MethodsEEG data were measured from thirty subjects as they performed a simple hand movement task. We utilized the five types of input data depending on the processing levels to assess the signal processing capability of our proposed deep learning model. The motor hotspot locations were estimated using a two-dimensional convolutional neural network (CNN) model. The error distance between the 3D coordinate information of the individual motor hotspots identified by the TMS (ground truth) and EEGs was calculated using the Euclidean distance. Additionally, we confirmed the clinical benefits of our proposed deep-learning algorithm by applying the EEG of stroke patients. ResultsA mean error distance between the motor hotspot locations identified by TMS and our approach was 2.34 {+/-} 0.19 mm when using raw data from only 9 channels around the motor area. When it was tested on stroke patients, the mean error distance was 1.77 {+/-} 0.15 mm using only 5 channels around the motor area. ConclusionWe have demonstrated that an EEG-based deep learning approach can effectively identify the individual motor hotspots. Moreover, we validated the clinical benefits of our algorithm by successfully implementing it in stroke patients. Our algorithm can be used as an alternative to TMS for identifying motor hotspots and maximizing rehabilitation effectiveness.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Choi, G.-Y., Seo, J.-K., Kim, K. T., Chang, W. K., Paik, N.-J., Kim, W.-S., Hwang, H.-J.. 2024-03-11. Motor Hotspot Localization Based on Electroencephalography Using Convolutional Neural Network in Patients with Stroke. https://doi.org/10.1101/2024.03.06.583618

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗