Search bioRxiv⌕ Search

bioRxiv · 10.1101/2024.02.27.582145

Introducing ARTiMiS: A low-cost flow imaging microscope for phytoplankton monitoring in engineered and natural environments

Abstract

Manual microscopy is the gold standard for phytoplankton monitoring in diverse engineered and natural environments. However, it is both labor-intensive and requires specialized training for accuracy and consistency, and therefore difficult to implement on a routine basis without significant time investment. Automation can reduce this burden by simplifying the measurement to a single indicator (e.g., chlorophyll fluorescence) measurable by a probe, or by processing samples on an automated cytometer for more granular information. The cost of commercially available flow imaging cytometers, however, poses a steep financial barrier to adoption. To overcome these labor and cost barriers, we developed ARTiMiS: the Autonomous Real-Time Microbial Scope. The ARTiMiS is a low-cost flow imaging microscopy-based platform with onboard software capable of providing species-level quantitation of phytoplankton communities in real-time. ARTiMiS leverages novel multi-modal imaging and onboard machine learning-based data processing that is currently optimized for a curated and expandable database of industrially relevant microalgae. We demonstrate its operational limits, performance in identification of laboratory-cultivated microalgae, and potential for continuous monitoring of complex microalgal communities in full-scale cultivation systems. SynopsisWe introduce a platform for low-cost real-time imaging monitoring of phytoplankton and demonstrate its utility in real-time monitoring of laboratory- and full-scale microalgal cultivation systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gincley, B., Khan, F., Hartnett, E., Fisher, A., Pinto, A. J.. 2024-03-03. Introducing ARTiMiS: A low-cost flow imaging microscope for phytoplankton monitoring in engineered and natural environments. https://doi.org/10.1101/2024.02.27.582145

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗