Search bioRxiv⌕ Search

bioRxiv · 10.1101/2024.02.13.580129

Soft Tissue Mechanics in Hip Distraction after Total Knee Arthroplasty: A Finite Element Analysis

Abstract

INTRODUCTIONImprovement in diagnostic and surgical techniques in hip arthroscopy have led to a surge in hip distraction procedures over the recent years with the predicted annual frequency being four out of every 10,000 orthopedic procedures in 2017. Due to the large traction force required to achieve the appropriate joint spacing intra-operatively, an emergence of traction-related neurological and soft tissue injuries have surfaced. Pre-existing hip joint pathologies and surgical procedures disrupt the biomechanical stability of the joint and significantly increase the risk of iatrogenic damage. Furthermore, patients with total knee arthroplasties are often subject to intra-articular ligament releases, leading to reduced stability; however, it is not well understood how this may impact their outcomes of hip arthroscopic procedures. The current study aims to investigate the biomechanical behavior of various instrumented knee joints subjected to traction forces to aid clinical understanding and advancements of hip arthroscopy techniques. METHODSA validated finite element (FE) model of the pelvis and lower extremity was developed from computed tomography (CT) scans of a healthy 45-year-old female. Three different models were assembled according to different TKA techniques performed: Bi-Cruciate Retaining (BCR) model, Posterior-Cruciate Retaining (PCR) model, and Posterior Stabilized (PS) model. The BCR model is noted by retaining all native ligaments of the knee joint (ACL, PCL, MCL, and LCL), whereas the PCR model was subject to ACL removal and the PS model required ACL and PCL removal (Figure 1). The pelvis was encastered to prevent translation under the traction forces as motion of the patients trunk is restrained, intraoperatively. To simulate the loading condition of hip distraction, an axial force was coupled to the distal fibula and tibia and incrementally increased from 100N to 500N. Joint spacing and ligament strain in the hip and knee joint were analyzed to assess the effects of traction forces. O_FIG O_LINKSMALLFIG WIDTH=174 HEIGHT=200 SRC="FIGDIR/small/580129v2_fig1.gif" ALT="Figure 1"> View larger version (70K): org.highwire.dtl.DTLVardef@1494014org.highwire.dtl.DTLVardef@e0fdeorg.highwire.dtl.DTLVardef@133cb56org.highwire.dtl.DTLVardef@16aaf02_HPS_FORMAT_FIGEXP M_FIG O_FLOATNOFigure 1.C_FLOATNO Meshed parts of the A.) Posterior Cruciate retaining total knee replacement system and the B.) Bi-cruciate retaining total knee replacement system. C_FIG RESULTSThe medial and lateral compartment stiffness of the knee joint was analyzed under hip distraction for the three different TKA scenarios. The BCR model displayed the greatest average knee complex stiffness. Release of the ACL resulted in a larger decrease of stiffness compared to release of the PCL. There was no change in forces required for hip distraction as result of changes in the knee joint stiffness (Figure 3). The PCR and PS models were subject to excess knee joint distraction that exceeded 12 mm and ligament strain greater than 20% before adequate hip joint distraction of 10 mm was achieved. The BCR model remained below 10 mm of knee distraction and 15% ligament strain at 10 mm of hip joint distraction. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=182 SRC="FIGDIR/small/580129v2_fig3.gif" ALT="Figure 3"> View larger version (90K): org.highwire.dtl.DTLVardef@107c292org.highwire.dtl.DTLVardef@77351corg.highwire.dtl.DTLVardef@40011aorg.highwire.dtl.DTLVardef@88e9c_HPS_FORMAT_FIGEXP M_FIG O_FLOATNOFigure 3.C_FLOATNO FE models of instrumented TKA. A) PCR TKA with simulated ACL release. B) PS TKA with simulated ACL and PCL releases. C) BCR TKA with intact ligaments. C_FIG DISCUSSIONOur study reveals patients undergoing hip distraction with a prior TKA may experience increased soft tissue damage or iatrogenic dislocation due to reduced knee joint stability. The PCR and PS models outline a trend suggesting patients who have undergone ligament sacrificing TKAs experience large reductions in knee joint stability, causing strain levels that are indicative of soft tissue injury. The BCR TKA was indicated to be the safest under the distraction conditions as joint spacing and strain levels were largely reduced comparatively; however, when surpassing 10 mm of knee joint distraction at forces greater than 350 N, the strain levels in the ACL suggest minor injury may occur.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Soehnlen, S. M., Sadeqi, S., Kumaran, Y., Tripathi, S., Jones, R. K., Sohn, D. H., Goel, V. K.. 2024-02-16. Soft Tissue Mechanics in Hip Distraction after Total Knee Arthroplasty: A Finite Element Analysis. https://doi.org/10.1101/2024.02.13.580129

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗