Improved Temporal and Spatial Focality of Non-invasive Deep-brain Stimulation using Multipolar Single-pulse Temporal Interference with Applications in Epilepsy

Abstract

Temporal Interference (TI) is an emerging method to non-invasively stimulate deep brain structures. This innovative technique is increasingly recognized for its potential applications in the treatment of various neurological disorders, including epilepsy, depression, and Alzheimers disease. However, several drawbacks to the TI method exist that we aim to improve upon. To begin, the applied electric field in the TI target is not much higher than what non-invasive transcranial alternating current stimulation (TACS) provides in the cortex. Additionally, the TI stimulation onset is dependent on the envelope of the amplitude modulated (AM) signal, where for example 1 Hz and 100 Hz envelopes have significantly different rise times to reach maximum envelope amplitude - unlike square biphasic pulses. This limitation in turn prevents classic TI, from applying bursts of pulses. Finally, the electric field intensity of TI cannot be increased or decreased at the target without dramatically altering the spatial profile of the stimulation focus. In the work presented here, we efficiently address all three of these limitations. First, we performed two-photon calcium imaging to show that individual neurons selectively respond to the TI envelope frequency, providing evidence that TI modulates neural activity with temporal specificity. This marks a significant advancement, representing the first empirical demonstration of neuronal activation at the {Delta}f frequency within the context of TI and in an imaging modality. Subsequently, we compared the AM signals of TI with phase-shift keying (PSK) modulated signals to highlight the superior effectiveness of noninvasive pulses in contrast to the traditional TI method, particularly in inducing epileptic activity (after-discharges) in mice. We also added a multipolar configuration to create a significant increase in the electric field at the target without significantly altering the spatial profile and applied Fourier components to replicate classic biphasic bursts of square pulses - all transcranially, without the use of penetrating electrodes. These innovations aim to enhance the precision and efficacy of TI stimulation, to advance its application in neurological research and therapy. Key Points / HighlightsO_LINon-invasive temporal interference stimulation modulates the activity of individual neurons at the envelope frequency. C_LIO_LIA non-invasive multi-pulse TI stimulation paradigm improves both temporal and spatial focality in the deep target neural tissue when compared to traditional continuous wave (amplitude-modulated) TI stimulation. C_LIO_LIPulse TI paradigms can stimulate deep neural targets with reduced amplitude of the topical high-frequency stimulation, decreasing off-target stimulation when compared to continuous wave TI patterns. As a consequence, pulse TI stimulation reduces the risk of undesired side effects such as high-frequency conduction block in off-target tissues or cortical areas. C_LIO_LIBoth temporal and spatial focality of the TI stimulation pattern positively correlate with the efficacy of the stimulation to induce seizures in the mouse hippocampus. C_LI

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

ACERBO, E., Botzanowski, B., Dellavale, D., Stern, M. A., Cole, E., Gutekunst, C.-A., Gantt, M., Steiner, M., MISSEY, F., Cassara, A., Neufeld, E., Berglund, K., Jirsa, V., Gross, R., Drane, D., Glowacki, E., Pakhomov, A., Williamson, A.. 2024-01-14. Improved Temporal and Spatial Focality of Non-invasive Deep-brain Stimulation using Multipolar Single-pulse Temporal Interference with Applications in Epilepsy. https://doi.org/10.1101/2024.01.11.575301

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Rab10 and Arhgef7 interact to promote axon extension by linking vesicle supply and exocytosis

The formation of functional neural circuits begins with the extension of a single axon by immature neurons. Axon elongation requires an expansion of the plasma membrane that depends on the polarization of vesicle trafficking and exocytosis. It is not completely understood how the increased transport of vesicles into the growing axon is linked to their subsequent insertion into the plasma membrane. An analysis of early stages of neuronal differentiation indicates that an asymmetry in neurite length precedes axon specification and the accumulation of PPVs in the nascent axon. We show that increasing the transport of vesicles in unpolarized neurons is sufficient to promote the extension of additional axons. This effect indicates that an increased supply of vesicles stimulates their subsequent insertion into the membrane to allow neurite growth. The link between vesicle transport and exocytosis is mediated by the interaction of Rab10 with Arhgef7. Rab10 stimulates Arhgef7 activity on PPVs as a GEF for Cdc42b to promote axon extension through exocyst-dependent exocytosis, suggesting that their interaction links the increased supply of PPVs to their exocytosis.

neuroscience↗

Subcellular Spatial Profiling Unveils Links Between Neuritic Plaques with Selective Tau Vulnerability in Alzheimer's Disease

Alzheimer's disease (AD) features widespread extracellular amyloid-{beta} plaques but selective intraneuronal tau accumulation in cortical layers II/III and V, while layer IV remains relatively resistant. Here, we combined subcellular spatial transcriptomics with co-registered A{beta} and pTau immunohistochemistry to determine why neurons exposed to comparable plaque-associated pathology differ in somatic pTau accumulation. Plaque-associated neuritic stress occurred similarly across layers, but layer IV neurons showed attenuated pTau accumulation and reduced somatic expression of a shared neurite-soma stress program involving DCTN1, CALM3, NORAD, and PIN1. Trajectory analysis within layers identified tau-vulnerable and resistant neuronal states implicating calcium signaling, retrograde transport, and lysosomal function. Notably, astrocytic APOE-neuronal LRP1 co-expression increased significantly along the pTau-vulnerable trajectory, and APOE {epsilon}4 was associated with stronger coupling of local plaque pathology to pTau-associated molecular programs. These findings reveal neuronal programs and neuron-glia interactions underlying selective tau vulnerability and resistance in AD, highlighting potential tau-targeting therapeutics.

neuroscience↗

Widespread oscillatory suppression in autism persists in the absence of psychotropic medication.

Purpose: Investigate the neural oscillatory activity associated with autism spectrum disorder (ASD) using electroencephalographic (EEG) recordings in children and adolescents. Compare the corresponding oscillatory power between ASD patients taking psychotropic medication with a drug-naive group. Methods: ASD diagnosis was done using DSM-IV and CARS (Childhood Autism Rating Scale). EEG recordings employed 22 scalp electrodes (10/20 system). ASD vs. neurotypical groups were matched for sex and age (5 females; average age: ~10 years old). We analyzed the resting state (eyes open) EEG power spectrum during ~2-minute recordings. The multitaper FFT method was used to estimate spectral power for the delta, theta, alpha, beta and gamma frequency bands. We pooled together data from several electrodes to compute comprehensive power spectra and assess the oscillatory behavior of macro brain regions. Results: We observed widespread (~4Hz - 20Hz) oscillatory suppression comprising the theta, alpha and beta frequency bands. The most widespread and robust ASD-associated power suppression was in the high theta and alpha bands. Delta and gamma bands showed no significant power change for any of the brain regions studied. Results from a subgroup of patients (N = 9) who never used psychotropics confirmed these findings, indicating that they are not an artifact of medication. Conclusion: Suppression in theta, alpha and beta oscillations may offer insights into the neurophysiological underpinnings of autism and could be used as an accessible and comprehensive tool in ASD diagnosis, regardless of the patients being or not on medication.

neuroscience↗