Search bioRxiv⌕ Search

bioRxiv · 10.1101/2024.01.06.574467

Development and validation of a subject-specific integrated finite element musculoskeletal model of human trunk with ergonomic and clinical applications

Abstract

Background and ObjectivesBiomechanical modeling of the human trunk is crucial for understanding spinal mechanics and its role in ergonomics and clinical interventions. Traditional models have been limited by only considering the passive structures of the spine in finite element (FE) models or incorporating active muscular components in multi-body musculoskeletal (MS) models with an oversimplified spine. This study aimed to develop and validate a subject-specific coupled FE-MS model of the trunk that integrates detailed representation of both the passive and active components for biomechanical simulations. MethodsWe constructed a parametric FE model of the trunk, incorporating a realistic muscle architecture, personalized through imaging datasets and statistical shape models. To validate the model, we compared tissue-level responses with in vitro experiments, and muscle activities and intradiscal pressures versus in vivo measurements during various physical activities. We further demonstrated the versatility of the proposed personalized integrated framework through additional applications in ergonomics (i.e., wearing an exoskeleton) and surgical interventions (e.g., nucleotomy and spinal fusion). ResultsThe model demonstrated satisfactory agreement with experimental data, showcasing its validity to predict tissue- and disc-level responses accurately, as well as muscle activity and intradiscal pressures. When simulating ergonomics scenarios, the exoskeleton-wearing condition resulted in lower intradiscal pressures (1.9 MPa vs. 2.2 MPa at L4-L5) and peak von Mises stresses in the annulus fibrosus (2.2 MPa vs. 2.9 MPa) during forward flexion. In the context of surgical interventions, spinal fusion at L4-L5 led to increased intradiscal pressure in the adjacent upper disc (1.72 MPa vs. 1.58 MPa), whereas nucleotomy minimally influenced intact disc pressures but significantly altered facet joint loads and annulus fibrosus radial strains. ConclusionsThe integrated FE-MS model of the trunk represents a significant advancement in biomechanical simulations, providing insights into the intricate interplay between active and passive spinal components. Its predictive capability extends beyond that of conventional models, enabling detailed risk analysis and the simulation of varied surgical outcomes. This comprehensive tool has potential implications for the design of ergonomic interventions and the optimization of surgical techniques to minimize detrimental effects on spinal mechanics.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ghezelbash, F., Eskandari, A. H., Shirazi-Adl, A., Lariviere, C.. 2024-01-08. Development and validation of a subject-specific integrated finite element musculoskeletal model of human trunk with ergonomic and clinical applications. https://doi.org/10.1101/2024.01.06.574467

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗

Lactate Receptor Activation Alleviates Senescence and Preserves Homeostasis of Aged Arteries

Arteries are among the first tissues to exhibit age-related dysfunction, yet the metabolic mechanisms driving vascular senescence remain poorly understood. Here, analysis of human aortic transcriptomic data identified HCAR1, encoding the lactate receptor GPR81, as one of the genes most significantly downregulated with age. We therefore investigated whether age-associated loss of GPR81 contributes to cellular senescence within the vessel wall. Senescent human endothelial cells and vascular smooth muscle cells accumulated neutral and oxidized lipids and exhibited increased labile iron and ferroptosis. Silencing GPR81 in early-passage cells recapitulated this metabolic phenotype together with multiple hallmarks of cellular senescence. Moreover, endothelial-specific deletion of GPR81 in young mice was sufficient to induce senescent cell accumulation, impaired lipid homeostasis, endothelial dysfunction, and elastin disorganization. Conversely, pharmacological activation of GPR81 with the agonist CHBA restored fatty acid metabolism, promoted glycolytic reprogramming, and attenuated ferroptotic stress and senescence-associated phenotypes. In lamin A knock-in (LAKI) progeroid mice, CHBA reduced arterial lipid accumulation and cellular senescence, shifted vascular cell composition toward a youthful state, improved endothelial integrity, and restored extracellular matrix homeostasis. Together, these findings identify age-associated loss of GPR81 as a driver of vascular metabolic dysfunction and cellular senescence and establish pharmacological GPR81 activation as a promising therapeutic strategy for preserving vascular homeostasis and mitigating age-associated cardiovascular disease.

bioengineering↗

Targeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy

Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25{+/-}7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 {+/-} 21.56% and 36.48 {+/-} 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p<0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.

bioengineering↗