Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.11.27.568947

In-bore MRI-compatible Transrectal Ultrasound and Photoacoustic Imaging

Abstract

Prostate cancer (PCa) is known as one of the most prevalent and fatal cancer types. This report describes an MRI-compatible photoacoustic/ultrasound (PA/US) imaging platform to improve the diagnosis of PCa. In the proposed solution, PA imaging, which offers real-time, non-ionizing imaging with high sensitivity and specificity, is combined with MRI, aiming to overcome PAs limited field of view (FOV) and make PA scalable for translation to clinical settings. Central to the design of the system is a reflector-based transrectal probing mechanism composed of MRI-compatible materials. The linear transducer with a center hole for optical fiber delivery can be mechanically actuated to form a multi-angled scan, allowing PA/US imaging from varied cross-sectional views. Performance assessment was carried out in phantom and ex-vivo settings. We confirmed the MRI compatibility of the system and demonstrated the feasibility of its tri-modal imaging capability by visualizing a tubing phantom containing contrast agents. The ex-vivo evaluation of targeted tumor imaging capability was performed with a mouse liver sample expressing PSMA-positive tumors, affirming the systems compatibility in spectroscopic PA (sPA) imaging with biological tissue. These results support the feasibility of the in-bore MRI-compatible transrectal PA and US and the potential clinical adaptability.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Murakami, R., Wang, Y., Lesniak, W., Tsumura, R., Tang, Y., Tsunoi, Y., Nycz, C. J., Pomper, M. G., Fischer, G. S., Zhang, H. K.. 2023-11-28. In-bore MRI-compatible Transrectal Ultrasound and Photoacoustic Imaging. https://doi.org/10.1101/2023.11.27.568947

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Circular-Arc Modal Migration for Ultrasound Imaging--Part II: Simulation and Experimental Evaluation in Compact Semicircular and Convex Arrays

Circular-arc ultrasound imaging requires reconstruction that accounts for curvature and offset transmit sources across a wide field. This study evaluates how Circular-Arc Modal Migration (CAMM) changes point-response width, image-energy distribution, and low-echo target separation relative to delay-and-sum (DAS). CAMM combines angular modal analysis, local spectral remapping, and radial synthesis, with the offset phase evaluated through phase screens or approximated by scalar pullback. Guided by Part I's error analysis and point-target comparisons, paired reconstructions use scalar pullback for compact semicircular cyst simulations and phase screens for acquisition-matched C5-2v simulations, six phantom records, and two carotid views from one participant. Each DAS/CAMM pair uses identical RF. The principal observation is that lower energy fractions outside a fixed neighborhood can coexist with broader tangential responses. In C5-2v point simulations, the full-field fraction is lower at 23 of 24 locations, whereas tangential width is greater at all 24. Semicircular cyst contrast improves in most configurations, with reversed ranking at the smallest target. All eight C5-2v cyst configurations at 10--15-mm radial depth favor CAMM in the three contrast measures; deeper comparisons depend on location and metric. Measured reflectors show the same width--energy-fraction pattern, and the evaluated phantom cyst and carotid lumen regions show improved contrast. At 512 x 513 pixels and 24 transmissions, median host latency is 29.79 ms for DAS and 51.87 ms for CAMM on an RTX 4090. The tested CAMM implementation therefore provides regional gains in low-echo target separation alongside broader tangential responses and higher computational cost.

bioengineering↗

QuickXL: An Open-source Ultraviolet Irradiation Device with Programmable Exposure and Active Cooling for Nucleic Acid Crosslinking

Accessible and reproducible ultraviolet (UV) exposure is important for many chemical and biochemical applications. We describe an open-source laboratory irradiation device designed for psoralen-mediated RNA photocrosslinking, a valuable tool for nucleic acid structure determination. The device is based on 24 nominally 365-370 nm light-emitting diode modules arranged as two selectable 12-emitter series arrays with separate drivers. A Nano-compatible microcontroller, four pushbuttons and an OLED display provide user-programmable light-on and light-off intervals and an elapsed-time limit. The arrays share a fan-cooled aluminum heatsink and sample chamber, and the device can operate inside a 4 {degrees}C refrigerator to limit sample warming. A 3D-printed enclosure incorporates a sliding cover and interchangeable tube and microplate configurations with an approximately 10 mm emitter-to-sample spacing. The design supports inexpensive, configurable irradiation for nucleic-acid sample preparation, and can be adapted for other light-triggered activation of biological samples.

bioengineering↗

Programmable Imaging of Locus-Specific DNA Repair Dynamics Reveals Chromatin-Controlled Therapy Resistance in Cancer

DNA double-strand breaks (DSBs) pose a significant threat to genomic integrity, and their efficient repair is critical for cell survival. However, the spatial and temporal aspects of the repair process at specific genomic loci remain a mystery. To address this gap, we developed a novel live-cell imaging platform called Genomic Locus Imaging and DSB Repair Monitoring by Elastin-like Proteins (GLIDRE). This system leverages a CRISPR-guided elastin-like protein (ELP) droplet approach to specifically label non-repetitive genomic loci and enables real-time analysis of repair-associated dynamics at the same site. Using GLIDRE, we demonstrate that DSB repair-associated dynamics are significantly faster in open chromatin regions compared to compacted regions, irrespective of local transcriptional activity, supporting a model in which chromatin accessibility defines the baseline response whereas transcriptional activity acts in a context-dependent manner. In a model of diffuse intrinsic pontine glioma (DIPG), the H3.3K27M mutation reshapes chromatin accessibility and repair dynamics in a locus-specific manner. At the tumor suppressor locus CDKN2A, H3.3K27M mutation caused a more repressive chromatin state and delayed repair-associated dynamics, which was associated with resistance to CAR T-cell therapy. Pretreatment with the histone deacetylase inhibitor suberoylanilide hydroxamic acid (SAHA) restores repair dynamics at CDKN2A and sensitizes H3.3K27M tumor spheroids to CAR T-cell therapy. Together, our findings reveal chromatin accessibility as a key determinant of DSB repair dynamics and support a mechanistic link and actionable connection between chromatin state, DNA repair, and immunotherapy response.

bioengineering↗