Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.11.09.566379

External Validation of Machine Learning and EEG for Continuous Pain Intensity Prediction in Healthy Individuals

Abstract

Previous research has predicted subjective pain intensity from electroencephalographic (EEG) data using machine learning (ML) models. However, there is a paucity of externally validated ML models for pain assessment, particularly for continuous pain prediction (e.g., decoding pain ratings on a 101-point scale). We aimed to conduct the first external validation paradigm for ML regression models for pain intensity prediction from EEG data. Ninety-one subjects were recruited across three samples. Sample one (n = 40) was used for model development, sample two (n = 51) was used as a cross-subject external validation set, whilst sample three (n = 25) was used as a within-subjects temporal external validation set. Pneumatic pressure stimuli were delivered to the left-hand index fingernail bed at 10 graded intensity levels. Single-trial time-frequency features of peri-stimulus EEG were used to train a Random Forest (RF) model and long short-term memory (LSTM) network to predict pain intensity responses. Results demonstrated that both the RF model and LSTM network predicted pain intensity significantly more accurately than a random prediction model, with the mean absolute error (MAE) of the RF (best performing model) at 19.59, 21.29, and 18.90 for internal validation, cross-subject external validation, and within-subject external validation, respectively. However, neither model was able to predict pain intensity better than a baseline dummy model, which predicted the mean behavioural rating of the training set and did not have access to neural data. Moreover, in a replication of our recent work, we developed a RF model for the classification of low and high-pain trials, which demonstrated internal and external validation accuracies up to 64% and 58%, respectively. Taken together, our results suggest that using ML and EEG to predict continuous pain ratings is not currently feasible. However, classification models demonstrate some potential, consistently outperforming chance across validation samples. Further improvements such as composite measures are required to elevate ML performance to a clinically meaningful level.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mari, T., Henderson, J., Ali, S. H., Hewitt, D., Brown, C., Stancak, A., Fallon, N.. 2023-11-13. External Validation of Machine Learning and EEG for Continuous Pain Intensity Prediction in Healthy Individuals. https://doi.org/10.1101/2023.11.09.566379

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

CoReg, tracking-based motion compensation for in vivo calcium imaging

In vivo calcium imaging enables the observation of neural activity with high spatial and temporal resolution. However, recordings are frequently affected by motion artifacts caused by animal movement, physiological processes, tissue drift, or instability of the imaging setup. These artifacts make signal extraction harder and reduce the consistency of downstream analyses. Current registration methods can correct rigid and non-rigid motion, but often estimate motion from individual frames or image patches and make limited use of temporal information. In addition, activity-driven fluorescence changes can make it difficult to distinguish changes in image appearance from actual motion. Here, we treat motion correction in calcium imaging as a point tracking problem and introduce CoReg, an open-source Python- based software tool with a graphical user interface. We benchmark CoReg against established registration methods using fluorescence imaging datasets from multiple species. CoReg performs competitively with or better than existing approaches across several settings. We further show that its performance is robust to the choice of tracked points, making the method straightforward to apply. CoReg includes implementations of both our method and the evaluated established methods. Our results show that tracking-based registration provides a simple and reliable approach for motion correction in vivo calcium imaging.

neuroscience↗

A shared slowing axis and phenotype-specific rhythms link clinical EEG to FDG-PET dementia phenotypes

Early and accurate identification of neurodegenerative disorders has notable implications for treatment and quality of life. Whereas neuroimaging-based biomarkers can accurately identify neurodegenerative subtypes, EEG represents a low-cost alternative that could expand access to dementia care. Here, we investigated whether six data-driven EEG latent factors, derived by nonnegative tensor decomposition of clinical EEGs, differ systematically across FDG-PET-defined neurodegenerative phenotypes. In 455 patients with EEG and FDG-PET acquired within one year of each other, factor expression was compared across 14 diagnostic classes assigned by StateViewer, a validated artificial intelligence framework for FDG-PET interpretation. To separate disease-general severity from phenotype-specific topography, each factor was also regressed on a subject-level slowing index. Finally, we related the factors to regional FDG uptake and to neuropsychological performance (n = 98) and assessed their potential utility for single-subject classification. Four factors reflecting neurophysiological oscillations (posterior alpha, Rolandic beta, frontotemporal delta-theta and posterior theta-slow alpha) varied significantly across phenotypes, with attenuation of faster and augmentation of slower rhythms most pronounced in dementia with Lewy bodies (DLB), dysexecutive Alzheimer disease (AD) and posterior cortical atrophy, whereas factors dominated by eye-movement and muscle artifact showed no robust phenotypic association. Alpha and beta effects were largely attributable to overall slowing, whereas posterior theta-slow alpha became more phenotype-specific after adjustment (eta-squared 0.082 to 0.147), dissociating the Alzheimer disease spectrum from frontotemporal syndromes. The slowing index tracked with an FDG-PET pattern highly associated with DLB across the cohort, irrespective of assigned phenotype (r = 0.51, P < 0.001). Consistent with a model in which dementia phenotypes reflect altered hippocampal-neocortical oscillatory coupling (stochastic latent oscillatory diffusion), frontotemporal delta-theta tracked a limbocortical axis of metabolic pattern expression, rising with neocortical and falling with limbic-predominant involvement, independent of overall slowing and phenotype. Each factor mapped onto a distinct metabolic topography, with frontotemporal delta-theta resembling Alzheimer-type hypometabolism and posterior theta-slow alpha the medial occipital hypometabolism of DLB. In terms of neuropsychological performance, Rolandic beta was associated with executive functions, and frontotemporal delta-theta with memory, visuospatial and global performance. Using these four factors alone, an exploratory logistic regression classifier separated cognitively unimpaired participants from DLB, posterior cortical atrophy, typical AD, and dysexecutive AD (area under the curve > 0.8) but poorly discriminated frontotemporal dementia phenotypes canonically associated with 4-repeat tau. Thus, data-driven decomposition of clinical EEG separates oscillatory activity from artifact into factors that track metabolic phenotype, regional metabolism and cognition, capturing both overall slowing and phenotype-specific patterns. This work informs the further development of scalable, biology-informed EEG-based phenotyping of neurodegenerative disease.

neuroscience↗

An application of fNIRS for the prediction of hearing thresholds in sleeping infants: a proof of principle

This study applied a two-component-response modelling approach to fNIRS recordings obtained from naturally sleeping infants presented with auditory stimuli at different sound intensities. We investigated whether the relationship between fNIRS response measures and stimulus intensity could be modelled to estimate individual auditory hearing thresholds. In the normal-hearing group, 75% of infants had threshold estimates for the sound /ba/ within the expected normal-hearing range, with an estimated mean equivalent normal loudness (ENL) of 10.72 dB HL (SD 8.64 dB HL). A case study further explored the potential application of this approach in an infant with hearing impairment, highlighting the importance of reliable responses at lower stimulus intensities and appropriate regression model selection. These findings provide preliminary evidence that cortical haemodynamic responses can be quantitatively related to sound intensity for estimating auditory sensitivity.

neuroscience↗