Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.10.02.560174

A compact, ultrahigh-density headstage with high-fidelity hybrid integration for large-scale deep-brain opto-electrophysiology

Abstract

Recent neuroscientific research seeks to comprehend the sophisticated deep-brain networks of neural circuits consisting of large scale neuronal ensembles across multiple brain regions. An ideal way to unveil the complex connectome might be stimulating individual neurons with high spatial resolution in a broad range of brain, while seamlessly monitoring the correspondent neuronal activities. Optogenetics is known as a key technology to enable such a goal thanks to its high spatial and temporal selectivity in neuromodulation. Existing silicon probe technologies have been able to partially achieve such a goal by recording broad region of brain activities through multiple electrodes per shank, but those cannot complete perfect coverage due to the limited channel counts for the optogenetic stimulation. Here, we present an high-channel-count optogenetic system with simultaneous 256 recoding and 128 optogenetic stimulation sites, exhibiting the highest channel density ever reported, enabled by a flexible polyimide cable-based hybrid-integration of a low-stimulation-artifact micro-LED ({micro}LED) opto-electrode with a low-power and -noise, area-efficient CMOS interfacing integrated-circuit (IC). The presented optogenetic system provides 256-neuron-size electrodes (11 x 15 {micro}m2) with a 40 {micro}m inter-electrode pitch for high spatial oversampling in recording and 128-soma-size {micro}LEDs (8 x 11 {micro}m2) with a 20 {micro}m inter-LED pitch for single-cell resolution in stimulation, resulting in a vertical span of 640 {micro}m and a horizontal span of 2,100 {micro}m with a total 8 shanks. For versatility in optogenetics-based experiments from small rodents to primates with user-preferable settings, the system base that provides programmability of recording and stimulation parameters and rest of signal processing, such as filtering, digitization, and data transmission including serial peripheral interface (SPI) has also been designed within small area of 23.8 x 28.8 mm2 with only 3.5-gram weight, resulting in the highest channel density both in size (0.56 channels/mm2) and weight (109.71 channels/gram) among the state-of-the-art optogenetics-based neuromodulation systems. To verify the system operation in vivo, a compact optogenetics headstage has been also fabricated. Using the prepared optogenetic headstage, 169 isolated neurons have been observed with various stimulation intensities. The results offered in this article indicate that the presented hybrid integrated ultrahigh-density, high-channel-count headstage can be used to realize the massive-scale in-depth brain studies with optogenetics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Oh, S., Kim, K., Lopez Ruiz, J. R., Slager, N., Ko, E., Vöröslakos, M., Lanzio, V., Song, H., Park, S.-Y., Yoon, E.. 2023-10-03. A compact, ultrahigh-density headstage with high-fidelity hybrid integration for large-scale deep-brain opto-electrophysiology. https://doi.org/10.1101/2023.10.02.560174

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗