Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.09.27.559680

Potential of MALDI-TOF MS biotyping to detect deltamethrin resistance in the dengue vector Aedes aegypti.

Abstract

Insecticide resistance in mosquitoes is spreading worldwide and represents a growing threat to vector control. Insecticide resistance is caused by different mechanisms including higher metabolic detoxication, target-site modification, reduced penetration and behavioral changes that are not easily detectable with simple diagnostic methods. Indeed, most molecular resistance diagnostic tools are costly and labor intensive and then difficult to use for routine monitoring of insecticide resistance. The present study aims to determine whether mosquito susceptibility status against the pyrethroid insecticides (mostly used for mosquito control) could be established by the protein signatures of legs and/or thoraxes submitted to MALDI-TOF Mass Spectrometry (MS). The quality of MS spectra for both body parts was controlled to avoid any bias due to unconformity protein profiling. The comparison of MS profiles from three inbreeds Ae. aegypti lines from French Guiana (IRF, IR03, IR13), with distinct deltamethrin resistance genotype / phenotype and the susceptible reference laboratory line BORA (French Polynesia), showed different protein signatures. On both body parts, the analysis of whole protein profiles revealed a singularity of BORA line compared to the three inbreeding lines from French Guiana origin, suggesting that the first criteria of differentiation is the geographical origin and/or the breeding history rather than the insecticide susceptibility profile. However, a deeper analysis of the protein profiles allowed to identify 10 and 11 discriminating peaks from leg and thorax spectra, respectively. Among them, a specific peak around 4870 Da was detected in legs and thoraxes of pyrethroid resistant lines compared to the susceptible counterparts hence suggesting that MS profiling may be promising to rapidly distinguish resistant and susceptible phenotypes. Further work is needed to confirm the nature of this peak as a deltamethrin resistant marker and to validate the routine use of MS profiling to track insecticide resistance in Ae. aegypti field populations. Author SummaryThe monitoring of mosquito insecticide resistance in local populations is essential to guide the choice of the vector control strategy. Current methods for resistance monitoring rely on biological, biochemical and molecular assays that all have their weakness. To circumvent these limitations, alternative methods have to be explored. In previous studies, MALDI-TOF MS profiling have proved it performance to classify mosquitoes at the species and sub-species levels. The present work aim was to assess whether MALDI-TOF MS profiling strategy could be useful for determination of mosquito susceptibility to the most used pyrethroid insecticide. In this way, four mosquito lines with distinct deltamethrin resistance genotype / phenotype were submitted to MS analysis. The accurate comparison of MS spectra showed different peak intensities between mosquitoes exhibiting different insecticide resistance profiles. Among discriminant peaks, one may be promising to detect insecticide-resistance mechanisms in public health mosquitoes. A better characterization of mosquito life traits will help countries to implement timely and locally adapted vector control interventions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

ALMERAS, L., Costa, M. M., Amalvict, R., Guillet, J., Dusfour, I., David, J.-P., Corbel, V.. 2023-09-27. Potential of MALDI-TOF MS biotyping to detect deltamethrin resistance in the dengue vector Aedes aegypti.. https://doi.org/10.1101/2023.09.27.559680

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Ferrybots: Programmable Hydrogel Microbots for Rapid Magnetic Navigation and Modular Function

Untethered microrobots could enable localized delivery, sensing, and intervention in confined biological and engineered environments. Magnetic actuation is especially attractive for such systems because it provides remote, fuel-free control, but practical magnetic microrobots remain difficult to manufacture and functionalize. High magnetic loading can interfere with polymerization and structural integrity, while integrating application-specific payloads directly into the robot body often requires the entire material formulation to be redesigned. Here, we introduce Ferrybots, programmable hydrogel microrobots that physically separate magnetic navigation from functional cargo. An automated droplet-on-demand microfluidic flow-lithography process confines high-concentration ferrofluid cores within photopolymerized poly (ethylene glycol) diacrylate (PEGDA) structures, enabling magnetic loading to be programmed through core number and spacing without uniformly dispersing magnetic particles throughout the hydrogel. The process achieved a minimum fabrication cycle time of 15 s. Ferrybots exhibited magnetic-dose-dependent translation and rotation, branched-channel steering, out-of-plane obstacle traversal, and rapid translation, with two-core robots following an external magnet at speeds up to the 9000 mm/min limit of the actuation system. Differences in magnetic loading also enabled sequential selective navigation of distinct Ferrybot populations. Using PEGDA 575 as a common interface material, independently formulated hydrogel cargo modules could subsequently be fused to preformed Ferrybots while preserving navigation. Separately, cargo modules enabled composition-dependent molecular release and oxygen-responsive sensing through 1-mm-thick skin-mimicking optical phantoms representing a broad range of skin types. By decoupling locomotion from function, Ferrybots provide a common magnetic vehicle that can be combined with interchangeable delivery, sensing, or responsive-material modules, offering a general strategy for rapidly adapting microrobots to different applications.

bioengineering↗

Circular-Arc Modal Migration for Ultrasound Imaging--Part I: Finite-Arc Spectral Theory and Stolt-Pullback Factorization

Circular-arc ultrasound imaging requires a spectral construction that accommodates radius-dependent propagation and the spatially varying phase of offset-source transmission. This first of two articles develops Circular-Arc Modal Migration (CAMM), a direct Stolt-type imaging framework in angular modal coordinates. Starting from a first-Born acoustic model, angular decomposition and local radial Stolt mappings convert channel spectra into fields for coherent image synthesis. The offset transmit phase is represented by a phase-screen factorization through reusable spectral factors and spatially weighted fields. A scalar-pullback approximation simplifies this correction to reading one reference image at a geometrically fitted radial coordinate. Both realizations share the same modal construction. Error controls address local radial synthesis, transmit-path expansion, scalar approximation, and phase-screen truncation, with direct integration verifying the separated numerical evaluation. Same-RF point-target comparisons show that scalar pullback closely preserves the principal peak positions and widths of phase-screen imaging in the compact semicircular configuration, while phase screens better control surrounding responses in the shallow convex examples. The retained modal spectrum, frequency band, image radius, and source displacement guide this accuracy--computation choice. CAMM thereby extends direct spectral image formation to circular arcs and supplies the theoretical and numerical basis for the image-quality and performance studies in Part~II.

bioengineering↗

Identification and isolation of migratory subpopulations of cancer cells using microfluidics with fluid walls

Microfluidic assays have great potential for investigating cancer cell migration, a key process underlying metastasis which remains a major clinical challenge. However, adoption by biologists is limited due to complex fabrication and operation methods combined with difficulty in retrieving cells of interest. We jet-print dumbbell-shaped microfluidic environments with fluid walls in standard Petri dishes in seconds using standard growth media and immiscible oil. Prostate cancer cells and chemoattractant (bovine serum) are introduced into each end using local transient differences in Laplace pressure to enable spatial confinement. Automated live-cell imaging monitors chemotaxis towards serum using standard microscopes, as the confining fluid walls are optically transparent. Distinct subpopulations of migratory cells exhibit different morphologies and motilities, assessed using a custom machine-learning segmentation model. Then, we leverage the reconfigurability of fluid walls to isolate and retrieve rapidly-migrating single cells. This demonstrates that fluid-walled microfluidics is a versatile and accessible approach for investigating cancer cell migration at single-cell resolution, offering new opportunities to examine cellular heterogeneity in metastasis.

bioengineering↗