Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.08.25.554314

Structural Determinants of Tendon Function During Development and Their Sensitivity to Mechanical Stimulation

Abstract

The load-bearing capabilities of tendon are acquired during neonatal stages of development, characterized by an abrupt increase in multiscale mechanical properties. While prior work has identified numerous changes within the collagenous structure during these developmental periods, the primary structural elements that give rise to this abrupt mechanical functionality, and their mechanobiological sensitivity, remains unclear. To address this gap in knowledge, we leveraged a combination of ultrastructural imaging, biochemical/thermodynamic assays, multiscale mechanical testing, and shear lag modeling to probe the dynamic structure-function relationships and establish their sensitivity to mechanical stimulation during tenogenesis. Mechanical testing and modeling suggested that the rapid increase in multiscale mechanics can be explained by a increasing fibril length and intrafibrillar crosslinking. To test this, we inhibited collagen crosslinking during development and observed a drastic reduction in multiscale mechanical capabilities that was explained by a reduction in both fibril modulus and length. Using muscle paralysis to investigate mechanosensitivity, we observed a significantly impaired multiscale mechanical response despite small changes in fibril diameter and fibril area fraction. While there was no change in crosslinking density, there was a decrease in thermal stability with flaccid paralysis, and our shear-lag model suggested that flaccid paralysis produces a reduction in fibril length and intrafibrillar crosslinking. Together, these data suggest that both intrafibrillar crosslink formation and fibril elongation are critical to the formation of load-bearing capabilities in tenogenesis and are sensitive to musculoskeletal activity. These findings provide critical insights into the biological mechanisms that give rise to load-bearing soft tissue.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Peterson, B. E., Canonicco Castro, M. L., McCarthy, H., Buckley, N., Dunne, N., Rolfe, R. A., Murphy, P., Szczesny, S.. 2023-08-27. Structural Determinants of Tendon Function During Development and Their Sensitivity to Mechanical Stimulation. https://doi.org/10.1101/2023.08.25.554314

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗