Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.08.12.553089

Hyaluronan Hydrogel "Safety Nets" for 3D Cell Culture Applications

Abstract

Polymeric hydrogels can mimic features of native extracellular matrix (ECM), and their facile production and characterization enable customizable cell encapsulation and 3-dimensional (3D) culture. These have applications relevant to dentistry such as soft tissue engineering, cancer modeling, and drug screening. Hyaluronan (HA), a biologically-derived polymer found in native ECM, offers an optimal platform for this use, as it can be modified covalently with adhesive ligands, enzyme-degradable crosslinkers, and other biorelevant moieties, yielding tailored physical properties and biological response. Cell-directed degradation of these encapsulating matrices can be a prerequisite for phenotype preservation, but degradation kinetics may not match desired timelines for drug screening applications. This study focused on optimizing hydrogel composition, network structure, and gelation kinetics to preserve z-distribution of physiologically relevant cells within high-throughput microfluidic plates. Hydrogels were formed from aqueous solutions of thiolated HA (HA-SH), bifunctional acrylated poly(ethylene glycol)-peptide crosslinkers, and pendant acrylated peptides (RGD or YIGSR sequences) to support cell adhesion. By varying the absolute crosslinker concentration and relative proportions of high:low crosslinker degradation kinetics, hydrogels could be tuned to desired moduli (G: [~]10-120 Pa) and enzymatic degradation rate. Ratios of high:low degradable crosslinkers, at equivalent total crosslinker concentration, minimally impacted final modulus or gelation rate. Similarly, pendant adhesive ligands were swapped easily with negligible impact on hydrogel physical properties. Hydrogels with a 50:50 ratio of high:low degradable crosslinkers provided a "safety net" that preserved z-distribution of encapsulated bone marrow-derived fibroblasts, while maintaining expected phenotype. A comparable system supported the 3D co-culture of primary human salivary epithelial and mesenchymal cells within a perfusable microfluidic multiwell plate. This customizable bottom-up construction reduced confounding factors encountered in hybridoma-derived protein matrices, enabling modular customization of physiologically relevant, yet reproducible matrices to replicate native ECM. Our optimized model demonstrates workflows to improve future pharmaceutical screens, and tailor tissue engineering applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wilson, R. T., Bonteanu, A., Harrington, D. A.. 2023-08-15. Hyaluronan Hydrogel "Safety Nets" for 3D Cell Culture Applications. https://doi.org/10.1101/2023.08.12.553089

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗