Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.08.07.552222

Simulated musculoskeletal optimization for sprinting and marathon running

Abstract

Musculoskeletal geometry and muscle volumes vary widely in the population and are intricately linked to the performance of tasks ranging from walking and running to jumping and sprinting. However, our ability to understand how these parameters affect task performance has been limited due to the high computational cost of modelling the necessary complexity of the musculoskeletal system and solving the requisite multi-dimensional optimization problem. For example, sprinting and running are fundamental to many forms of sport, but past research on the relationships between musculoskeletal geometry, muscle volumes, and running performance has been limited to observational studies, which have not established cause-effect relationships, and simulation studies with simplified representations of musculoskeletal geometry. In this study, we developed a novel musculoskeletal simulator that is differentiable with respect to musculoskeletal geometry and muscle volumes. This simulator enabled us to find the optimal body segment dimensions and optimal distribution of added muscle volume for sprinting and marathon running. Our simulation results replicate experimental observations, such as increased muscle mass in sprinters, as well a mass in the lower end of the healthy BMI range and a higher leg-length-to-height ratio in marathon runners. The simulations also reveal new relationships, for example showing that hip musculature is vital to both sprinting and marathon running. We found hip flexor and extensor moment arms were maximized to optimize sprint and marathon running performance, and hip muscles the main target when we simulated strength training for sprinters. Our simulation results can help sprint and marathon runners customize strength training, and our simulator can be extended to other athletic tasks, such as jumping, or to non-athletic applications, such as designing interventions to improve mobility in older adults or individuals with movement disorders. AUTHOR SUMMARYOur study addresses the challenge of determining optimal musculoskeletal parameters for tasks like sprinting and marathon running. Existing research has been limited to observational studies and simplified simulations. To overcome these limitations, we developed a differentiable musculoskeletal simulator to optimize running performance. We replicated past findings and uncovered new insights. We confirmed the benefits of increased muscle mass for sprinters and identified key factors for marathon runners, such a mass in the lower end of the healthy BMI range and an increased leg-length-to-height ratio. Hip musculature was found to be critical for both sprinting and marathon running. Our simulation results have practical implications. They can inform customized strength training for sprinters and marathon runners. Additionally, the simulator can be extended to other athletic tasks, benefiting various sporting events. Beyond athletics, our open-source simulator has broader applications. It can determine minimal strength requirements for daily activities, guide strength training in the elderly, and estimate the effects of simulated musculoskeletal surgery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Van Wouwe, T., Hicks, J., Delp, S., Liu, K.. 2023-08-07. Simulated musculoskeletal optimization for sprinting and marathon running. https://doi.org/10.1101/2023.08.07.552222

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗