Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.08.04.551983

Is Inappropriate Pulse Timing Responsible for Poor Binaural Hearing with Cochlear Implants?

Abstract

Cochlear implants (CIs) have restored enough of a sense of hearing to around one million severely hearing impaired patients to enable speech understanding in quiet. However, several aspects of hearing with CIs remain very poor. This includes a severely limited ability of CI patients to make use of interaural time difference (ITD) cues for spatial hearing and noise reduction. A major cause for this poor ITD sensitivity could be that current clinical devices fail to deliver ITD information in a manner that is accessible to the auditory pathway. CI processors measure the envelopes of incoming sounds and then stimulate the auditory nerve with electrical pulse trains which are amplitude modulated to reflect incoming sound envelopes. The timing of the pulses generated by the devices is largely or entirely independent of the incoming sounds. Consequently, bilateral CIs (biCIs) provide veridical envelope (ENV) ITDs but largely or entirely replace the "fine structure" ITDs that naturally occur in sounds with completely arbitrary electrical pulse timing (PT) ITDs. To assess the extent to which this matters, we devised experiments that measured the sensitivity of deafened rats to precisely and independently controlled PT and ENV ITDs for a variety of different CI pulse rates and envelope shapes. We observed that PT ITDs completely dominate ITD perception, while the sensitivity to ENV ITDs was almost negligible in comparison. This strongly suggests that the confusing yet powerful PT ITDs that contemporary clinical devices deliver to biCI patients may be a major cause of poor binaural hearing outcomes with biCIs. Significance StatementCIs deliver spectro-temporal envelopes, including speech formants, to severely deaf patients, but they do little to cater to the brains ability to process temporal sound features with sub-millisecond precision. CIs "sample" sound envelope signals rapidly and accurately, and thus provide information which should make it possible in principle for CI listeners to detect envelope ITDs in a similar way to normal listeners. However, here we demonstrate through behavioral experiments on CI implanted rats trained to detect sub-millisecond ITDs that pulse timing ITDs completely dominate binaural hearing. This provides the strongest confirmation to date that the arbitrary pulse timing widely used in current clinical CIs is a critical obstacle to good binaural hearing through prosthetic devices.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Schnupp, J. W., Buchholz, S., Buck, A. N., Budig, H. K., Khurana, L., Rosskothen-Kuhl, N.. 2023-08-04. Is Inappropriate Pulse Timing Responsible for Poor Binaural Hearing with Cochlear Implants?. https://doi.org/10.1101/2023.08.04.551983. https://searchbiorxiv.org/record/biorxiv%3A10.1101%2F2023.08.04.551983/is-inappropriate-pulse-timing-responsible-for-poor-binaural-hearing-with-cochlear-implants

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search bioRxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related preprints

Remodeling of Trigeminal Neuron Subtypes in Chronic Orofacial Pain

Chronic orofacial pain conditions, including trigeminal neuralgia, post-traumatic trigeminal neuropathic pain, and neuropathic temporomandibular disorder-related pain, remain clinically intractable. The trigeminal ganglion (TG) contains primary sensory neurons that convey sensory information from the face and oral cavity, making TG subtype-specific injury responses central to persistent craniofacial pain. However, how individual TG neuronal subtypes respond to nerve injury during chronic pain remains poorly understood. Prior single-cell injury datasets often used nerve transection models for neuropathic pain that induce strong, transient injury and regeneration-associated states. To define TG transcriptional remodeling in a model of trigeminal neuropathic pain, we performed single-nucleus RNA sequencing of mouse TG after infraorbital nerve chronic constriction injury (IoN-CCI), comparing acute (Day 7) and chronic (Day 21) stages. Analyzing 17,801 nuclei, we identified an initial injury-associated neuronal expression pattern enriched for regeneration biomarkers (Atf3, Sox11) at Day 7 that was not detected at Day 21. Unlike transection models, in which injured neurons converge on a shared injury-associated transcriptional state, IoN-CCI largely retained recognizable canonical neuronal identities while revealing delayed remodeling at Day 21. Cross-model comparisons with published TG axotomy and DRG sciatic nerve transection datasets showed limited overlap, supporting model- and ganglion-specific remodeling with trigeminal constriction injury. Acute TG responses were characterized by stress and injury-associated transcriptional programs, whereas chronic-stage transcriptional programs were enriched for synaptic/structural remodeling and ion channel reconfiguration. Chronic remodeling was most evident in canonical p-cLTMR2 mechanosensory and Trpm8-positive PEP2 cold-sensitive neurons, and RNAscope validated induction of Tmem45b and Rgs8 in Gfra2-positive neurons and Fgf13 and Kcnmb2 in Trpm8-positive neurons. Our findings demonstrate that IoN-CCI drives stage- and neuronal subtype-specific transcriptional remodeling within canonical trigeminal neurons. These findings identify neuronal subtype-specific molecular changes associated with persistent orofacial neuropathic pain and highlight candidates for future therapeutic investigation.

neuroscience↗

Plume Events: Rapid and Local Increases in Blood-Brain Barrier Permeability Tuned to Behavior, Predicted by Endothelial Calcium Events and Driven by Histaminergic Axons

AO_SCPLOWBSTRACTC_SCPLOWChoosing correct actions, and learning from them, requires detailed knowledge of current biological needs. Signals carried in vessels are an unfiltered source of such internal state information for the brain. However, the Forebrain blood-brain barrier (BBB) is typically thought to restrict real-time access to almost all such signals. This general restriction is crucial to health, as sustained BBB weakening is a major risk. Here, we tested a potential resolution to these competing needs for information versus safety, the prediction that the BBB can be dynamic, providing rapid and local access to vascular signals but only when body state information is worth the risk (the State Gate Hypothesis). Such events could also benefit health, including metabolic microsupply and focal waste clearance, timed and targeted to the focus of activity. To test these predictions, we imaged movement of inert, large (70 kD) fluorescent dextrans from vessels into Primary Somatosensory Neocortex (SI) in awake, behaving mice. We found Plume Events, transient increases in BBB permeability aligned to key behavioral events. Early in training on a Pavlovian version of a Vibrissal Cue task, rapid fluorescence increases in the parenchyma occurred immediately preceding Reward ( Pre), and then [~]750-1000ms Post-Reward. When trained for a sustained period on an Instrumental-version of this task, these two distinct epochs were again observed in all mice. In addition, a shift to the Sensory Cue emerged. These findings emerged when considering fluorescence transmission to the parenchyma averaged across all trials, and when discrete Plume Events were detected. While the amplitude of Plume Events and a parallel vascular dynamic, arterial dilation, were correlated, they were not mutually required, as Plume Events emerged even when trials without a detectable dilation occurred. Calcium events predict chemical transmission in many body systems, including action potential invasion of the axon terminal. Studies of in vitro systems show that Endothelial Calcium increases drive cell-layer barrier permeability. To test whether Endothelial Cell Calcium Events (ECCE) drive Plume Events, we imaged mice expressing GaCMP8* in Endothelial Cells. During behavior of our task, these mice showed robust increases in ECCE timed to Sensory onset and Reward. ECCE predicted Plume Event onset, with larger GCaMP signals predicting increased permeability. Further, ECCE predicted proximal Plume Events that onset within <15m but not further. Histamine (HA) induces Endothelial Calcium signals and rapid, transient, calcium-dependent increases in BBB permeability. The Histaminergic Tuberomaxillary Nucleus (TMN) of the Hypothalamus projects axons throughout the Forebrain that contact vessels directly, including in Primary Somatosensory Neocortex. TMN activity increases during invigorated states, especially thirst-motivated arousal, imposed during our imaging conditions. We therefore reasoned that HA inputs may drive Plume Events in our task. We found that HA axons in SI responded at short latency to Sensory Cue and Reward preceding local Plume Event onset. Further, trials with HA axon activity showed robuset Plume Events, while those without a detected event showed smaller Plume Events. Optogenetic activation of these axons also drove robust dilation on all trials, and Plume Events on the first several trials before decreasing in efficacy. This phenomenal sensitization matches known pharmacological effects of decreased BBB permeability following minutes long exposure. Dilations did not show sensitization and were evident throughout the session. These data support a new conceptual frame and time scale for BBB dynamics, one that is immediate, local and transactional to ongoing focal information processing. These data indicate that the high-dimensional body state information carried as a continuous chemical code in the vasculature is made available to the Forebrain in distinct moments of behavioral relevance. This form of Direct Interoception may provide a unique, rich snapshot to enhance Forebrain computation, complementing Indirect Interoception that is mediated through action potential coding, and supports brain health by locally-tuned metabolic supply and clearance.

neuroscience↗

Cardiac-confidence coupling is modulated by sensory but not higher-order uncertainty

Confidence, the subjective sense of certainty accompanying decisions, may be shaped by more than the sensory evidence on which the decision itself was based. Cardiac signals have been linked to confidence, with some evidence that this coupling strengthens when sensory evidence is unreliable. However, sensory evidence can be unreliable in different ways: if sensory input is degraded, predictive cues are misleading, or the environment is too volatile for stable expectations to form. These are distinct computational problems, and whether cardiac-confidence coupling is engaged under all of them has not yet been tested. Similarly, whether this coupling predicts individual differences in metacognitive efficiency remains unknown. To address this, we recorded cardiac activity from 167 participants performing a face-emotion discrimination task that orthogonally manipulated sensory precision, cue validity, and block volatility, with trial-wise confidence ratings. Pre-decisional heart rate deceleration was more pronounced under low than high sensory precision. Within this window, trial-level heart rate positively predicted confidence, independently of accuracy and precision. This cardiac-confidence coupling was stronger when sensory precision was low, but cue validity and block volatility did not modulate the coupling. Neither individual resting heart rate variability nor coupling strength predicted metacognitive efficiency. Together, these findings indicate that cardiac-confidence coupling is modulated by sensory uncertainty but not by higher-order uncertainty, consistent with a within-trial interoceptive weighting mechanism rather than a stable individual-differences trait.

neuroscience↗