Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.07.24.550304

Single-cell precision nanotechnology in vivo

Abstract

Targeting nanoparticle therapeutics with cellular accuracy in whole organisms could open breakthrough opportunities in precision medicine. However, evaluating and fine-tuning the biodistribution of such systems in the whole organism at the cellular level remains a major obstacle. Here, we constructed targetable DNA origami, and analyzed biodistribution in transparent mice, in addition to studying tolerability, clearance kinetics, and immune response parameters. Untargeted DNA origami primarily accumulated in the spleen and the liver, while an immune cell-targeting variant successfully attached to immune cells throughout the body. A cancer cell-targeting mimetic co-localized on solid-tumor metastasis in the liver and the lung. These findings indicate that DNA origami can be directed in vivo, providing an important proof-of-concept and highlights the potential of high-resolution tissue-clearing imaging technologies in their development. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=121 SRC="FIGDIR/small/550304v1_ufig1.gif" ALT="Figure 1"> View larger version (44K): org.highwire.dtl.DTLVardef@ce216borg.highwire.dtl.DTLVardef@f40bb4org.highwire.dtl.DTLVardef@2c6a66org.highwire.dtl.DTLVardef@1fd7fde_HPS_FORMAT_FIGEXP M_FIG C_FIG HighlightsO_LIThis study demonstrates the potential of DNA origami-based drug delivery systems as versatile tool for for targeted delivery, which could be used to treat a range of diseases with applications. C_LIO_LIThe immune compatibility, half-life, targeting efficiency, and the biodistribution evaluation of DNA origami indicate its potential for systemic drug delivery. C_LIO_LIOur approach enables the assessment of biodistribution of nanoparticles in the intact body with a sensitivity to the single-cell level, highlighting the high-resolution tissue clearing technoloies in revealing DNA origamis feasibility for drug targeting. C_LI

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

MOLBAY, M., Kick, B., Zhao, S., Todorov, M. I., Ohn, T.-L., Roth, S., Simats, A., Singh, V., Khalin, I., Pan, C., Singh Bhatia, H., Hellal, F., Zeidler, R., Liesz, A., Plesnila, N., Dietz, H., Erturk, A.. 2023-07-26. Single-cell precision nanotechnology in vivo. https://doi.org/10.1101/2023.07.24.550304

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗

PROST: An Open Toolbox, Harmonised Multi-Lab Dataset, and Meta-Analysis of Ankle-Foot Roll-Over Shape

The ankle-foot roll-over shape (ROS) is the sagittal-plane path of the centre of pressure (CoP) during the stance phase of walking, expressed in a shank-based coordinate system. It describes the effective rocker geometry that emerges from both the shape and the elastic deformation of the ankle-foot system during walking, and informs prosthetic and orthotic design. Previous studies characterised ROS in small samples with differing laboratory protocols, so they have not systematically assessed inter-individual variability or its relation to anthropometrics. We developed the open-source Public ROS Toolbox (PROST) for standardised ROS computation, and used it to harmonise marker trajectories, ground reaction forces and CoP data from four public gait datasets collected in independent laboratories. For each leg, we fitted a circular arc to the pooled ROS of all its stance phases. In a one-stage individual-participant data meta-analysis, linear mixed-effects models, with dataset as a fixed effect and participant as a random intercept, related the arc radius and the horizontal coordinate of the circle centre to anthropometrics, and, in the two self-selected-speed datasets, to walking speed. The harmonised dataset comprises 249 participants and 5,667 stance phases at walking speeds of 0.7-8.5 km/h. Circular arcs fitted the ROS closely (mean RMS radial residual 1.9 mm). The radius had a median of 410.3 mm (interquartile range, IQR, 237.6 mm), and the circle centre lay posterior to the ankle (median -20.6 mm, IQR 49.5 mm). Between-participant differences, quantified by the intraclass correlation coefficient (ICC), accounted for 42% of the variance in log radius (95% CI 25-57%) and 47% of the variance in the horizontal coordinate of the circle centre (95% CI 24-65%). Anthropometrics explained a negligible share of this variance (radius: pseudo-R2 -0.001, 95% CI -0.03 to 0.12), and height normalisation did not reduce radius variability (robust coefficient of variation 43% with and without normalisation). Faster self-selected walking was associated with a larger radius and a more posterior circle centre. To our knowledge, this study provides the first harmonised multi-lab ROS dataset. Together with the open-source toolbox, it is publicly available to support reproducible research in gait biomechanics, rehabilitation device design and clinical gait assessment. ROS geometry was participant-specific but was not predicted by age, sex, height or mass. A device ROS scaled from anthropometrics is therefore unlikely to match an individual's ROS, motivating studies of whether matching it, through device geometry and stiffness, improves gait mechanics.

bioengineering↗