Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.02.02.526859

Rosuvastatin-Eluting Gold Nanoparticle-Loaded Perivascular Implantable Wrap for Enhanced Arteriovenous Fistula Maturation in a Murine Model

Abstract

BackgroundArteriovenous fistulas (AVFs) are a vital intervention for patients requiring hemodialysis, but they also contribute to overall mortality due to access malfunction. The most common cause of both AVF non-maturation and secondary failure is neointimal hyperplasia (NIH). Absorbable polycaprolactone (PCL) perivascular wraps can address these complications by incorporating drugs to attenuate NIH, such as rosuvastatin (ROSU), and metallic nanoparticles for visualization and device monitoring. ObjectivesThis study aimed to assess the impacts of gold nanoparticle (AuNP) and ROSU-loaded perivascular wraps on vasculature NIH and AVF maturation and patency in a chronic kidney disease rat model. MethodsElectrospun wraps containing combinations of PCL, AuNP, and ROSU were monitored for in vitro drug elution, nanoparticle release, tensile strength, and cell viability. Perivascular wraps were implanted in chronic kidney disease rats for in vivo ultrasound (US) and micro-computed tomography (mCT) imaging. AVF specimens were collected for histological analyses. ResultsNo difference in cell line viability was observed in ROSU-containing grafts. In vitro release studies of ROSU and AuNPs correlated with decreasing radiopacity over time on in vivo mCT analysis. The mCT study also demonstrated increased radiopacity in AuNP-loaded wraps compared with PCL and control. The addition of ROSU demonstrated decreased US and histologic measurements of NIH. ConclusionsThe reduced NIH seen with ROSU-loading of perivascular wraps suggests a synergistic effect between mechanical support and anti-hyperplasia medication. Furthermore, the addition of AuNPs increased wrap radiopacity. Together, our results show that radiopaque, AuNP-, and ROSU-loaded PCL grafts induce AVF maturation and suppress NIH while facilitating optimal implanted device visualization.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Klusman, C., Martin, B., Perez, J. V. D., Barcena, A. J. R., Bernardino, M. R., San Valentin, E. M. D., Damasco, J. A., Del Mundo, H. C., Court, K., Godin, B., Fowlkes, N., Bouchard, R. R., Cheng, J., Huang, S. Y., Melancon, M. P.. 2023-02-03. Rosuvastatin-Eluting Gold Nanoparticle-Loaded Perivascular Implantable Wrap for Enhanced Arteriovenous Fistula Maturation in a Murine Model. https://doi.org/10.1101/2023.02.02.526859

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗