Search bioRxiv⌕ Search

bioRxiv · 10.1101/2023.01.28.522839

Acoustic trapping and navigation of microrobots in the mouse brain vasculature

Abstract

Many cerebrovascular and neurodegenerative diseases are currently challenging to treat due to the complex and delicate anatomy of the brain. The use of microrobots can create new opportunities in brain research due to their ability to access hard-to-reach regions and empower various biological applications; however, little is known about the functionality of microrobots in the brain, owing to their limited imaging modalities and intravascular challenges such as high blood flow velocities, osmotic pressures, and cellular responses. Here, we present an acoustic, non-invasive, biocompatible microrobot actuation system, for in vivo navigation in the bloodstream, in which microrobots are formed by lipid-shelled microbubbles that aggregate and propel under the force of acoustic irradiation. We investigated their capacities in vitro within a microfluidic 3D setup and in vivo in a living mouse brain. We show that microrobots can self-assemble and navigate upstream in the brain vasculature. Our microrobots achieved upstream velocities of up to 1.5 m/s and overcame blood flows of ~10 mm/s. Our results prove that microbubble-based microrobots are scalable to the complex 3D living milieu. Significance StatementNumerous brain diseases, including ischemic stroke, Alzheimers disease, and glioblastoma, may benefit from local and targeted therapies. Although they show great promise, microrobots have not yet demonstrated successful in vivo navigation inside the brain, as the challenging flow conditions and the complex 3D vascular network in the brain pose fundamental limitations. Here, we apply acoustically driven microrobots with the capacity for self-assembly and real-time navigation, including navigation against blood flow up to 10 mm/s, used for the first time inside the brain vasculature of a living mouse. The ultrasound manipulation of microrobots inside animal models provides a much-needed pathway for the advancement of preclinical research.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fonseca, A. D. C., Gluck, C., Droux, J., Ferry, Y., Frei, C., Wegener, S., Weber, B., El Amki, M., Ahmed, D.. 2023-01-30. Acoustic trapping and navigation of microrobots in the mouse brain vasculature. https://doi.org/10.1101/2023.01.28.522839

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗