Effect of field strength on RF power deposition near conductive leads: A simulation study of SAR in DBS lead models during MRI at 1.5 T - 10.5 T

Abstract

BackgroundSince the advent of magnetic resonance imaging (MRI) nearly four decades ago, there has been a quest for ever-higher magnetic field strengths. Strong incentives exist to do so, as increasing the magnetic field strength increases the signal-to-noise ratio of images. However, ensuring patient safety becomes more challenging at high and ultrahigh field MRI (i.e., [≥]3 T) compared to lower fields. The problem is exacerbated for patients with conductive implants, such as those with deep brain stimulation (DBS) devices, as excessive local heating can occur around implanted lead tips. Despite extensive effort to assess radio frequency (RF) heating of implants during MRI at 1.5 T, a comparative study that systematically examines the effects of field strength and various exposure limits on RF heating is missing. PurposeThis study aims to perform numerical simulations that systematically compare RF power deposition near DBS lead models during MRI at common clinical and ultra-high field strengths, namely 1.5, 3, 7, and 10.5 T. Furthermore, we assess the effects of different exposure constraints on RF power deposition by imposing limits on either the B1+ or global head specific absorption rate (SAR) as these two exposure limits commonly appear in MRI guidelines. MethodsWe created 33 unique DBS lead models based on postoperative computed tomography (CT) images of patients with implanted DBS devices and performed electromagnetic simulations to evaluate the SAR of RF energy in the tissue surrounding lead tips during RF exposure at frequencies ranging from 64 MHz (1.5 T) to 447 MHz (10.5 T). The RF exposure was implemented via realistic MRI RF coil models created based on physical prototypes built in our institutions. We systematically examined the distribution of local SAR at different frequencies with the input coil power adjusted to either limit the B1+ or the global head SAR. ResultsThe MRI RF coils at higher resonant frequencies generated lower SARs around the lead tips when the global head SAR was constrained. The trend was reversed when the constraint was imposed on B1+. ConclusionAt higher static fields, MRI is not necessarily more dangerous than at lower fields for patients with conductive leads. Specifically, when a conservative safety criterion, such as constraints on the global SAR, is imposed, coils at a higher resonant frequency tend to generate a lower local SAR around implanted leads due to the decreased B1+ and, by proxy, E field levels.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kazemivalipour, E., Sadeghi-Tarakameh, A., Keil, B., Eryaman, Y., Atalar, E., Rad, L. G.. 2022-12-15. Effect of field strength on RF power deposition near conductive leads: A simulation study of SAR in DBS lead models during MRI at 1.5 T - 10.5 T. https://doi.org/10.1101/2022.12.13.520303

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Mechanism of molecular recognition revealed through dynamic drug binding pathways to SARS-CoV-2 main protease

Characterization of drug-binding pathways remains experimentally limited by transient intermediates and computationally challenging due to long timescales intractable for conventional molecular dynamics. To address these challenges, we combined solution NMR titrations with weighted ensemble (WE) enhanced sampling simulations to resolve atomistic pathways of nirmatrelvir binding to the SARS-CoV-2 main protease. NMR titration revealed residue-dependent heterogeneity spanning fast, intermediate, and slow exchange regimes. WE simulations complement the NMR by providing insights into unassigned residues and adding time-resolved and three-dimensional structural context. We map key interactions along two distinct binding pathways, provide dynamic explanations for residues involved in resistance, and capture unique backbone conformations compared to those sampled in unbound or bound states. Our comprehensive binding model is consistent with a combined conformational selection and induced fit mechanism in which early transient contacts are made with residues E47 and L50 and allosteric motions are centered around residue V204 of the distal domain. This synergistic application of WE and titration NMR enables a more comprehensive characterization of drug binding than either method alone, providing an integrated framework that may have broader applicability to defining structure-kinetic relationships and guiding design of next-generation inhibitors.

biophysics↗

Fibers and Glasses are Competing Material States in FUS Protein Condensation

Dense, well-ordered material states of proteins form the amyloid fibers that are a hallmark of neurodegenerative disease in the brain. Beyond forming amyloid fibers, some of these proteins can also adopt other material states termed condensates which are initially liquid-like but evolve to a soft, glassy phase. Fiber growth requires a large supply of monomers and, thus, it is often speculated that fibers emerge from within a dense condensate as it ages and its microscopic dynamics slow into a glassy state. Here, we use the well-established model system Fused in Sarcoma (FUS) to directly observe, quantify and theoretically describe fiber growth and its interplay with condensates. We report the discovery that fibers grow overwhelmingly in the dilute phase surrounding the condensates while the condensates concurrently evolve to a glassy arrested solid. The resulting protein fibers and glassy condensates are both distinct solid-like phases that coexist but do not directly interconvert. Taken together, these findings reveal that there are two competitive aging pathways in FUS condensation that are linked through phase separation kinetics.

biophysics↗

A Minimally Perturbative DARPin Probe for Quantitative Fluorescence Imaging of the Human TCR-CD3 Complex

Fluorescence microscopy is a powerful tool for dissecting the molecular mechanisms of T-cell antigen recognition in living cells, but its quantitative insight critically depends on non-perturbative, high-quality probes. Here, we repurpose a small (~15 kDa) CD3epsilon-binding DARPin (designed ankyrin repeat proteins) to a fluorescent label for T-cell receptor (TCR)/CD3 complexes on primary human CD8+ T-cells, with the aim of generating a powerful tool for quantitative analysis, single-molecule tracking, and advanced imaging of TCR dynamics. We show that the DARPin binds CD3{varepsilon} with high affinity and selectivity and using single molecule tracking and brightness analysis, we characterize the TCR-CD3 diffusion behavior and show that the DARPin binds to both CD3epsilon; subunits. Importantly, labeling preserves antigen sensitivity: on supported lipid bilayers presenting cognate pMHC, T-cells remain responsive, assemble synapses, form TCR microclusters, and initiate signaling similar to unlabeled controls. We further demonstrate compatibility with lattice light-sheet microscopy for volumetric imaging of T-cell - APC interactions in living cells. Together, these results establish DARPins as versatile, minimally perturbative probes for high resolution, quantitative studies of T cell synapse organization and signaling.

biophysics↗