Search bioRxiv⌕ Search

bioRxiv · 10.1101/2022.12.08.519188

Investigation of Soft Magnetic Material Cores in Transcranial Magnetic Stimulation Coils and the Effect of Changing Core Shapes on the Induced Electric Field in Small Animals

Abstract

Transcranial magnetic stimulation (TMS) is a safe, effective and non-invasive treatment for several psychiatric and neurological disorders. Lately, there has been a surge in research utilizing this novel technology in treating other neurological and psychiatric ailments. The application of TMS on several neurological disorders requires the induced electric and magnetic fields to be focused and targeted to a small region in the brain. TMS of a focal cortical territory will ensure modulation of specific brain circuitry without affecting unwanted surrounding regions. This can be achieved by altering the properties of the magnetic core material used for the TMS system. In this study, soft ferromagnetic materials having high permeability, high saturation magnetization and low coercivity have been investigated as TMS coil cores in finite element simulations. Also, magnetic field measurements have been carried out using different cores in the TMS coil. Finite element analysis of the rat head model is carried out using Sim4life software while investigating variations associated with changing the ferromagnetic core material and shape in the coil. Materials proposed for the analysis in this study include Iron Cobalt Vanadium alloy (Fe-Co-V) also known as Permendur, Carbon Steel (AISI 1010) and Manganese Zinc ferrites (MnZn ferrites). Simulation results indicated significant magnetic field distribution variation when introducing a ferromagnetic core in TMS coil, concentrating the magnetic field to the targeted region in the rat head model without stimulating adjacent regions. It was observed that the v-tip sharpened core attained the highest magnetic field and best focality among other cores in simulations and experimentally.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tashli, M., Weistroffer, G., Mhaskar, A., Kumbhare, D., Baron, M. S., Hadimani, R. L.. 2022-12-12. Investigation of Soft Magnetic Material Cores in Transcranial Magnetic Stimulation Coils and the Effect of Changing Core Shapes on the Induced Electric Field in Small Animals. https://doi.org/10.1101/2022.12.08.519188

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗