Search bioRxiv⌕ Search

bioRxiv · 10.1101/2022.11.23.517726

Micromagnetic Stimulation (μMS) Dose-Response of the Rat Sciatic Nerve

Abstract

ObjectiveThe objective of this study was to investigate the effects of micromagnetic stimuli strength and frequency from the Magnetic Pen (MagPen) on the rat right sciatic nerve. The nerves response would be measured by recording muscle activity and movement of the right hind limb. ApproachThe MagPen was custom-built such that it can be held over the sciatic nerve in a stable manner. Rat leg muscle twitches were captured on video and movements were extracted using image processing algorithms. EMG recordings were also used to measure muscle activity. Main resultsThe MagPen prototype when driven by alternating current, generates time-varying magnetic field which as per Faradays Law of Electromagnetic Induction, induces an electric field for neuromodulation. The orientation dependent spatial contour maps for the induced electric field from the MagPen prototype has been numerically simulated. Furthermore, in this in vivo work on MS, a dose-response relationship has been reported by experimentally studying how the varying amplitude (Range: 25 mVp-p through 6 Vp-p) and frequency (Range: 100 Hz through 5 kHz) of the MagPen stimuli alters the hind limb movement. The primary highlight of this dose-response relationship is that at a higher frequency of the MS stimuli, significantly smaller amplitudes can trigger hind limb muscle twitch. This frequency-dependent activation can be justified following directly from the Faradays Law as the magnitude of the induced electric field is directly proportional to frequency. SignificanceThis work reports that MS can successfully activate the sciatic nerve in a dose-dependent manner. The MagPen probe, unlike electrodes, does not have a direct electrochemical interface with tissues rendering it much safer than an electrode. Magnetic fields create more precise activation than electrodes because they induce smaller volumes of activation. Finally, unique features of MS such as orientation dependence, directionality and spatial selectivity have been demonstrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Saha, R., Sanger, Z., Bloom, R., Benally, O., Wu, K., Tonini, D., Low, W. C., Keirstead, S., Netoff, T. I., Wang, J.-P.. 2022-11-25. Micromagnetic Stimulation (μMS) Dose-Response of the Rat Sciatic Nerve. https://doi.org/10.1101/2022.11.23.517726

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗