Abstract

BackgroundThe first-pass complete recanalization by mechanical thrombectomy (MT) for the treatment of stroke remains limited due to the poor integration of the clot within current devices. Aspiration can help retrieval of the main clot but fails to prevent secondary embolism in the distal arterial territory. The dense meshes of extracellular DNA, recently described in stroke-related clots, might serve as an anchoring platform for MT devices. ObjectiveEvaluate the potential of DNA reacting surface to aid the retention of the main clot as well as of its small fragments within the thrombectomy device and improve the potential of MT procedures. MethodsDevice-suitable alloy experimental samples were coated with 15 different compounds and contacted with extracellular DNA or with human peripheral whole blood, to compare their binding to DNA versus flowing blood elements, in vitro. Clinical-grade MT devices were coated with two selected compounds and evaluated in functional bench tests aiming to studying clot retrieval and distal emboli release, concomitant with contact aspiration, using an M1 occlusion model. ResultsBinding properties of samples coated with all compounds were increased for DNA ({approx} 3-fold) and decreased ({approx} 5-fold) for blood elements, essentially platelet, as compared to the bare alloy samples, in vitro. Functional testing showed that surface modification with DNA-binding compounds improved clot retrieval and significantly reduced secondary embolism during experimental recanalization of occluded artery 3D model by thrombectomy procedures. ConclusionOur results suggest that device coating with DNA-binding compounds can considerably improve the outcome of MT procedures in stroke patients. What is already known on this topic - New mechanical thrombectomy device are being improved on the conformation and shape to increase the interaction clot on the physical point of view. However, none interact specifically with the structure or composition of the clot. What this study adds - The design of a chemical surface modification of the device opens the way for a specific targeting tool to increase the interaction with the clot on the molecular level. How this study might affect research, practice or policy - This new surface modification, which can be applied to all commercially available mechanical thrombectomy devices, leads to a decrease in secondary embolization which cannot and is not monitored during the procedure and responsible for new territory damage.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Skarbek, C., Anagnostakou, V., Procopio, E., Epshtein, M., Raskett, C., Romagnoli, R., Iviglia, G., Morra, M., Antonucci, M., Nicoletti, A., Caligiuri, G., Gounis, M.. 2022-10-24. Development of a clot-adhesive coating to improve the performance of thrombectomy devices. https://doi.org/10.1101/2022.10.18.512663

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗