Search bioRxiv⌕ Search

bioRxiv · 10.1101/2022.06.23.497372

Canary in the cardiac-valve coal mine: Flow velocity and inferred shear during prosthetic valve closure --predictors of blood damage and clotting

Abstract

ObjectiveTo demonstrate a clear link between predicted blood shear forces during valve closure and thrombogenicity that explains the thrombogenic difference between tissue and mechanical valves and provides a practical metric to develop and refine prosthetic valve designs for reduced thrombogenicity. MethodsPulsatile and quasi-steady flow systems were used for testing. The time-variation of projected open area (POA) was measured using analog opto-electronics calibrated to projected reference orifice areas. Flow velocity determined over the cardiac cycle equates to instantaneous volumetric flow rate divided by POA. For the closed valve interval, data from quasi-steady back pressure/flow tests was obtained. Performance ranked by derived maximum negative and positive closing flow velocities, evidence potential clinical thrombogenicity via inferred velocity gradients (shear). Clinical, prototype and control valves were tested. ResultsBlood shear and clot potential from multiple test datasets guided empirical optimization and comparison of valve designs. Assessment of a 3-D printed prototype valve design (BV3D) purposed for early soft closure demonstrates potential for reduced thrombogenic potential. ConclusionsThe relationship between leaflet geometry, flow velocity and predicted shear at valve closure illuminated an important source of prosthetic valve thrombogenicity. With an appreciation for this relationship and based on our experiment generated comparative data, we achieved optimization of valve prototypes with potential for reduced thrombogenicity. Competing InterestsNone declared. Financial DisclosureThis research has been done on a pro bono basis by all authors. Graphical AbstractVisualization of water jetting through closed mechanical heart valve under steady flow. Under pulsatile conditions, similar jet patterns near valve closure and leaflet rebound are likely. Dynamic metrics for several valves assessed in vitro are important in prediction of comparable blood cell damage and potential life-threatening thrombotic outcomes. Red star indicates moment of valve closure. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=169 SRC="FIGDIR/small/497372v11_ufig1.gif" ALT="Figure 1"> View larger version (57K): org.highwire.dtl.DTLVardef@95677forg.highwire.dtl.DTLVardef@bdc94dorg.highwire.dtl.DTLVardef@1eaf113org.highwire.dtl.DTLVardef@1792ade_HPS_FORMAT_FIGEXP M_FIG C_FIG CENTRAL MESSAGEA derived laboratory metric for valve closing flow velocity offers a way to rank valve models for potential blood damage. These results provide new insight and a mechanistic explanation for prior clinical observations where aortic and mitral valve replacements differ in thrombogenic potential and anticoagulation requirement. The study suggests a path forward to design and evaluate novel mechanical valve models for future development. As multiple modifications to mechanical and bioprosthetic valves have not resolved chronic shortcomings related to thrombogenicity and durability, a new development avenue was required to lead to eliminate thrombogenicity in the former and extend durability in the latter. PERSPECTIVEProsthetic mechanical valve devices cause blood cell damage. Activation of the coagulation cascade is initiated by dynamic valve function. Design innovation focusing on valve closure behavior may reduce valve thrombogenic potential. Our study demonstrates that valve design can be empirically optimized with emphasis on that phase. SIGNIFICANCEEmphasis on open valve performance has encouraged a long-standing bias while under appreciation of the closing phase vital to identification of potential thrombogenic complications persist. Our multiple data sets are useful in challenging this bias. Dynamic motion(s) of mechanical valves and derived regional flow velocity are impacted by valve geometry. Focus on valve closure dynamics may lead to the development of potentially less thrombogenic prototype valves. Laboratory experiments support the supposition that valve regional flow velocity is associated with valve thrombogenic potential. This study compares three clinical valves and two experimental prototypes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Scotten, L. N., Siegel, R., Blundon, D. J., Deutsch, M.-A., Martin, T. R. P., Dutton, J. W., Kolahdouz, E. M., Griffith, B. E.. 2022-06-26. Canary in the cardiac-valve coal mine: Flow velocity and inferred shear during prosthetic valve closure --predictors of blood damage and clotting. https://doi.org/10.1101/2022.06.23.497372

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Ferrybots: Programmable Hydrogel Microbots for Rapid Magnetic Navigation and Modular Function

Untethered microrobots could enable localized delivery, sensing, and intervention in confined biological and engineered environments. Magnetic actuation is especially attractive for such systems because it provides remote, fuel-free control, but practical magnetic microrobots remain difficult to manufacture and functionalize. High magnetic loading can interfere with polymerization and structural integrity, while integrating application-specific payloads directly into the robot body often requires the entire material formulation to be redesigned. Here, we introduce Ferrybots, programmable hydrogel microrobots that physically separate magnetic navigation from functional cargo. An automated droplet-on-demand microfluidic flow-lithography process confines high-concentration ferrofluid cores within photopolymerized poly (ethylene glycol) diacrylate (PEGDA) structures, enabling magnetic loading to be programmed through core number and spacing without uniformly dispersing magnetic particles throughout the hydrogel. The process achieved a minimum fabrication cycle time of 15 s. Ferrybots exhibited magnetic-dose-dependent translation and rotation, branched-channel steering, out-of-plane obstacle traversal, and rapid translation, with two-core robots following an external magnet at speeds up to the 9000 mm/min limit of the actuation system. Differences in magnetic loading also enabled sequential selective navigation of distinct Ferrybot populations. Using PEGDA 575 as a common interface material, independently formulated hydrogel cargo modules could subsequently be fused to preformed Ferrybots while preserving navigation. Separately, cargo modules enabled composition-dependent molecular release and oxygen-responsive sensing through 1-mm-thick skin-mimicking optical phantoms representing a broad range of skin types. By decoupling locomotion from function, Ferrybots provide a common magnetic vehicle that can be combined with interchangeable delivery, sensing, or responsive-material modules, offering a general strategy for rapidly adapting microrobots to different applications.

bioengineering↗

Circular-Arc Modal Migration for Ultrasound Imaging--Part I: Finite-Arc Spectral Theory and Stolt-Pullback Factorization

Circular-arc ultrasound imaging requires a spectral construction that accommodates radius-dependent propagation and the spatially varying phase of offset-source transmission. This first of two articles develops Circular-Arc Modal Migration (CAMM), a direct Stolt-type imaging framework in angular modal coordinates. Starting from a first-Born acoustic model, angular decomposition and local radial Stolt mappings convert channel spectra into fields for coherent image synthesis. The offset transmit phase is represented by a phase-screen factorization through reusable spectral factors and spatially weighted fields. A scalar-pullback approximation simplifies this correction to reading one reference image at a geometrically fitted radial coordinate. Both realizations share the same modal construction. Error controls address local radial synthesis, transmit-path expansion, scalar approximation, and phase-screen truncation, with direct integration verifying the separated numerical evaluation. Same-RF point-target comparisons show that scalar pullback closely preserves the principal peak positions and widths of phase-screen imaging in the compact semicircular configuration, while phase screens better control surrounding responses in the shallow convex examples. The retained modal spectrum, frequency band, image radius, and source displacement guide this accuracy--computation choice. CAMM thereby extends direct spectral image formation to circular arcs and supplies the theoretical and numerical basis for the image-quality and performance studies in Part~II.

bioengineering↗

Identification and isolation of migratory subpopulations of cancer cells using microfluidics with fluid walls

Microfluidic assays have great potential for investigating cancer cell migration, a key process underlying metastasis which remains a major clinical challenge. However, adoption by biologists is limited due to complex fabrication and operation methods combined with difficulty in retrieving cells of interest. We jet-print dumbbell-shaped microfluidic environments with fluid walls in standard Petri dishes in seconds using standard growth media and immiscible oil. Prostate cancer cells and chemoattractant (bovine serum) are introduced into each end using local transient differences in Laplace pressure to enable spatial confinement. Automated live-cell imaging monitors chemotaxis towards serum using standard microscopes, as the confining fluid walls are optically transparent. Distinct subpopulations of migratory cells exhibit different morphologies and motilities, assessed using a custom machine-learning segmentation model. Then, we leverage the reconfigurability of fluid walls to isolate and retrieve rapidly-migrating single cells. This demonstrates that fluid-walled microfluidics is a versatile and accessible approach for investigating cancer cell migration at single-cell resolution, offering new opportunities to examine cellular heterogeneity in metastasis.

bioengineering↗