Search bioRxiv⌕ Search

bioRxiv · 10.1101/2022.04.12.488033

Expanding adult tubular microvessels on stiff substrates with endothelial cells and pericytes from the same tissue

Abstract

Microvessels are essential for tissue engineering and regeneration. In current methods, endothelial cells are usually cultured in commercially available media and form a monolayer of cell sheets on stiff substrates and a tubular structure when cultured with soft hydrogels. To mimic the microvessels in vivo, researchers usually coculture the endothelial cells and pericytes from different adult tissues or derived from pluripotent stem cells in a three-dimensional hydrogel. However, there is a challenge for these models to reflect tissue-specific characteristics due to the vascular heterogeneity throughout the body. Here, we established a culture model for expanding adult tubular microvessels on stiff substrates with endothelial cells and pericytes derived from the same tissue. We isolated microvessels from adult rat subcutaneous soft connective tissue and cultured them on regular plastic dishes. We performed a series of screenings and formulated a custom-made medium (Medium-X), containing mainly antioxidants and three small molecules, Chir99021, A83-01, and Y27632. Medium-X significantly promoted adult microvessel growth while maintaining their characteristic tubular morphology up to 8 weeks in vitro, contrary to the monolayer of endothelial cell sheets in the commercially available medium EGM2MV. Transcriptomic analysis showed that Medium-X maintained the tubular morphology of microvessels by promoting angiogenesis and vascular remodeling while suppressing oxidation and lipid metabolic pathways. The model presented in this study can be applied to other organs for expanding organ-specific microvessels for tissue engineering and vascular regeneration.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Song, X., Yu, Y., Mu, J., Wang, Z., Leng, Y., Xu, Y., Zhu, H., Qiu, X., Li, P., Li, J., Wang, D.. 2022-04-12. Expanding adult tubular microvessels on stiff substrates with endothelial cells and pericytes from the same tissue. https://doi.org/10.1101/2022.04.12.488033

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗