Closed-Loop Control of Anesthetic State in Non-Human Primates

Abstract

Continuous monitoring of electroencephalogram (EEG) recordings in humans under general anesthesia (GA) has demonstrated that changes in EEG dynamics induced by an anesthetic drug are reliably associated with the altered arousal states caused by the drug. This observation suggests that an intelligent, closed-loop anesthesia delivery (CLAD) system operating in real-time could track EEG dynamics and control the infusion rate of a programmable pump to precisely maintain unconsciousness. The United States FDA acknowledges the potential benefits of such automatic physiological closed-loop control devices for patient care. Bringing these devices into clinical practice requires establishing their feasibility in suitable animal models. Therefore, given the close neurophysiological proximity between human and non-human primates (NHPs), we address this problem by developing and validating a propofol CLAD system in rhesus macaques. Our CLAD system has three key components: (1) a data acquisition system that records cortical local field potentials (LFPs) from an NHP in real-time; (2) a computer executing our CLAD algorithm that takes in the LFP signals as input and outputs infusion rates; and (3) a computer-controlled infusion pump that administers intravenous propofol. Our CLAD system controls an empirically-determined LFP marker of unconsciousness (MOU) at a user-prescribed target value by updating every 20 seconds the propofol infusion rate based on real-time processing of the LFP signal. The MOU is the instantaneous power in the 20 to 30 Hz band of the LFP spectrogram. Every cycle (duration{approx} 20 sec), our CLAD algorithm updates the MOU estimate and uses a robust optimal control strategy to adjust the propofol infusion rate based on the instantaneous error. This error is computed as the difference between the current and the user-prescribed target MOU values. Using neural recordings from multiple NHP anesthesia sessions, we first established that our chosen MOU signal was strongly correlated with propofol-induced decreased spiking activity which itself has been shown earlier to be associated with the level of unconsciousness in NHPs. Then we designed robust optimal control strategies that used subject-specific pharmacokinetic-pharmacodynamic models describing the MOU dynamics due to propofol infusion rate changes. Finally, we achieved safe and efficient closed-loop control of level of unconsciousness in 9 CLAD experiments involving 2 NHPs and 2 different 125 min long target MOU profiles with three target MOU changes within a given experiment. Our CLAD system performs stably, accurately and robustly across a total of 1125 min of closed-loop control. The CLAD performance measures, represented as median (25th percentile, 75th percentile), are 3.13 % (2.62%, 3.53%) for inaccuracy, 0.54 %(-0.31%, 0.89%) for bias, -0.02%/min (-0.06%/min, 0.00%/min) for divergence, and 3% (2.49%, 3.59%) for wobble. These performance measures were comparable or superior to previously reported CLAD performance measures from clinical studies (conducted outside USA) as well as rodent-based studies. The key innovations here are: (1) a pre-clinical NHP model for CLAD development and testing, (2) a neuroscience-informed LFP-based MOU for CLAD, (3) parsimonious, pharmacology-informed models to describe MOU dynamics under propofol infusion in rhesus macaques, (4) a novel numerical testing framework for propofol CLAD that incorporates a principled optimal robust control strategy for titrating propofol, and finally (5) experimental findings demonstrating the feasibility of stable, accurate and robust CLAD in the NHP model. Our NHP-based CLAD framework provides a principled pre-clinical research platform that can form the foundation for future clinical studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chakravarty, S., Donoghue, J. A., Waite, A. S., Mahnke, M., Garwood, I. C., Miller, E. K., Brown, E. N.. 2021-09-13. Closed-Loop Control of Anesthetic State in Non-Human Primates. https://doi.org/10.1101/2021.09.12.459958

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗