Search bioRxiv⌕ Search

bioRxiv · 10.1101/2021.09.12.459958

Closed-Loop Control of Anesthetic State in Non-Human Primates

Abstract

Continuous monitoring of electroencephalogram (EEG) recordings in humans under general anesthesia (GA) has demonstrated that changes in EEG dynamics induced by an anesthetic drug are reliably associated with the altered arousal states caused by the drug. This observation suggests that an intelligent, closed-loop anesthesia delivery (CLAD) system operating in real-time could track EEG dynamics and control the infusion rate of a programmable pump to precisely maintain unconsciousness. The United States FDA acknowledges the potential benefits of such automatic physiological closed-loop control devices for patient care. Bringing these devices into clinical practice requires establishing their feasibility in suitable animal models. Therefore, given the close neurophysiological proximity between human and non-human primates (NHPs), we address this problem by developing and validating a propofol CLAD system in rhesus macaques. Our CLAD system has three key components: (1) a data acquisition system that records cortical local field potentials (LFPs) from an NHP in real-time; (2) a computer executing our CLAD algorithm that takes in the LFP signals as input and outputs infusion rates; and (3) a computer-controlled infusion pump that administers intravenous propofol. Our CLAD system controls an empirically-determined LFP marker of unconsciousness (MOU) at a user-prescribed target value by updating every 20 seconds the propofol infusion rate based on real-time processing of the LFP signal. The MOU is the instantaneous power in the 20 to 30 Hz band of the LFP spectrogram. Every cycle (duration{approx} 20 sec), our CLAD algorithm updates the MOU estimate and uses a robust optimal control strategy to adjust the propofol infusion rate based on the instantaneous error. This error is computed as the difference between the current and the user-prescribed target MOU values. Using neural recordings from multiple NHP anesthesia sessions, we first established that our chosen MOU signal was strongly correlated with propofol-induced decreased spiking activity which itself has been shown earlier to be associated with the level of unconsciousness in NHPs. Then we designed robust optimal control strategies that used subject-specific pharmacokinetic-pharmacodynamic models describing the MOU dynamics due to propofol infusion rate changes. Finally, we achieved safe and efficient closed-loop control of level of unconsciousness in 9 CLAD experiments involving 2 NHPs and 2 different 125 min long target MOU profiles with three target MOU changes within a given experiment. Our CLAD system performs stably, accurately and robustly across a total of 1125 min of closed-loop control. The CLAD performance measures, represented as median (25th percentile, 75th percentile), are 3.13 % (2.62%, 3.53%) for inaccuracy, 0.54 %(-0.31%, 0.89%) for bias, -0.02%/min (-0.06%/min, 0.00%/min) for divergence, and 3% (2.49%, 3.59%) for wobble. These performance measures were comparable or superior to previously reported CLAD performance measures from clinical studies (conducted outside USA) as well as rodent-based studies. The key innovations here are: (1) a pre-clinical NHP model for CLAD development and testing, (2) a neuroscience-informed LFP-based MOU for CLAD, (3) parsimonious, pharmacology-informed models to describe MOU dynamics under propofol infusion in rhesus macaques, (4) a novel numerical testing framework for propofol CLAD that incorporates a principled optimal robust control strategy for titrating propofol, and finally (5) experimental findings demonstrating the feasibility of stable, accurate and robust CLAD in the NHP model. Our NHP-based CLAD framework provides a principled pre-clinical research platform that can form the foundation for future clinical studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chakravarty, S., Donoghue, J. A., Waite, A. S., Mahnke, M., Garwood, I. C., Miller, E. K., Brown, E. N.. 2021-09-13. Closed-Loop Control of Anesthetic State in Non-Human Primates. https://doi.org/10.1101/2021.09.12.459958

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗

PROST: An Open Toolbox, Harmonised Multi-Lab Dataset, and Meta-Analysis of Ankle-Foot Roll-Over Shape

The ankle-foot roll-over shape (ROS) is the sagittal-plane path of the centre of pressure (CoP) during the stance phase of walking, expressed in a shank-based coordinate system. It describes the effective rocker geometry that emerges from both the shape and the elastic deformation of the ankle-foot system during walking, and informs prosthetic and orthotic design. Previous studies characterised ROS in small samples with differing laboratory protocols, so they have not systematically assessed inter-individual variability or its relation to anthropometrics. We developed the open-source Public ROS Toolbox (PROST) for standardised ROS computation, and used it to harmonise marker trajectories, ground reaction forces and CoP data from four public gait datasets collected in independent laboratories. For each leg, we fitted a circular arc to the pooled ROS of all its stance phases. In a one-stage individual-participant data meta-analysis, linear mixed-effects models, with dataset as a fixed effect and participant as a random intercept, related the arc radius and the horizontal coordinate of the circle centre to anthropometrics, and, in the two self-selected-speed datasets, to walking speed. The harmonised dataset comprises 249 participants and 5,667 stance phases at walking speeds of 0.7-8.5 km/h. Circular arcs fitted the ROS closely (mean RMS radial residual 1.9 mm). The radius had a median of 410.3 mm (interquartile range, IQR, 237.6 mm), and the circle centre lay posterior to the ankle (median -20.6 mm, IQR 49.5 mm). Between-participant differences, quantified by the intraclass correlation coefficient (ICC), accounted for 42% of the variance in log radius (95% CI 25-57%) and 47% of the variance in the horizontal coordinate of the circle centre (95% CI 24-65%). Anthropometrics explained a negligible share of this variance (radius: pseudo-R2 -0.001, 95% CI -0.03 to 0.12), and height normalisation did not reduce radius variability (robust coefficient of variation 43% with and without normalisation). Faster self-selected walking was associated with a larger radius and a more posterior circle centre. To our knowledge, this study provides the first harmonised multi-lab ROS dataset. Together with the open-source toolbox, it is publicly available to support reproducible research in gait biomechanics, rehabilitation device design and clinical gait assessment. ROS geometry was participant-specific but was not predicted by age, sex, height or mass. A device ROS scaled from anthropometrics is therefore unlikely to match an individual's ROS, motivating studies of whether matching it, through device geometry and stiffness, improves gait mechanics.

bioengineering↗