bioRxiv · 10.1101/2021.08.31.458385
Refining epileptogenic high-frequency oscillations using deep learning: a reverse engineering approach
Abstract
Intracranially-recorded interictal high-frequency oscillations (HFOs) have been proposed as a promising spatial biomarker of the epileptogenic zone. However, visual verification of HFOs is time-consuming and exhibits poor inter-rater reliability. Furthermore, no method is currently available to distinguish HFOs generated from the epileptogenic zone (epileptogenic HFOs: eHFOs) from those generated from other areas (non-epileptogenic HFOs: non-eHFOs). To address these issues, we constructed a deep learning (DL)-based algorithm using HFO events from chronic intracranial electroencephalogram (iEEG) data via subdural grids from 19 children with medication-resistant neocortical epilepsy to: 1) replicate human expert annotation of artifacts and HFOs with or without spikes, and 2) discover eHFOs by designing a novel weakly supervised model (HFOs from the resected brain regions are initially labeled as eHFOs, and those from the preserved brain regions as non-eHFOs). The "purification power" of DL is then used to automatically relabel the HFOs to distill eHFOs. Using 12,958 annotated HFO events from 19 patients, the model achieved 96.3% accuracy on artifact detection (F1 score = 96.8%) and 86.5% accuracy on classifying HFOs with or without spikes (F1 score = 80.8%) using patient-wise cross-validation. Based on the DL-based algorithm trained from 84,602 HFO events from nine patients who achieved seizure-freedom after resection, the majority of such DL-discovered eHFOs were found to be HFOs with spikes (78.6%, p < 0.001). While the resection ratio of detected HFOs (number of resected HFOs/number of detected HFOs) did not correlate significantly with post-operative seizure freedom (the area under the curve [AUC]=0.76, p=0.06), the resection ratio of eHFOs positively correlated with post-operative seizure freedom (AUC=0.87, p=0.01). We discovered that the eHFOs had a higher signal intensity associated with ripple (80-250 Hz) and fast ripple (250-500 Hz) bands at the HFO onset and with a lower frequency band throughout the event time window (the inverted T-shaped), compared to non-eHFOs. We then designed perturbations on the input of the trained model for non-eHFOs to determine the models decision-making logic. The model probability significantly increased towards eHFOs by the artificial introduction of signals in the inverted T-shaped frequency bands (mean probability increase: 0.285, p < 0.001), and by the artificial insertion of spike-like signals into the time domain (mean probability increase: 0.452, p < 0.001). With this DL-based framework, we reliably replicated HFO classification tasks by human experts. Using a reverse engineering technique, we distinguished eHFOs from others and identified salient features of eHFOs that aligned with current knowledge. Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=200 SRC="FIGDIR/small/458385v1_ufig1.gif" ALT="Figure 1"> View larger version (81K): org.highwire.dtl.DTLVardef@39977dorg.highwire.dtl.DTLVardef@108b182org.highwire.dtl.DTLVardef@1bdf864org.highwire.dtl.DTLVardef@fe9e57_HPS_FORMAT_FIGEXP M_FIG C_FIG
Source connections
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Zhang, Y., Lu, Q., Monsoor, T., Hussain, S. A., Qiao, J. X., Salamon, N., Fallah, A., Sim, M. S., ASANO, E., Sankar, R., Staba, R. J., Engel, J., Speier, W., Roychowdhury, V., Nariai, H.. 2021-09-01. Refining epileptogenic high-frequency oscillations using deep learning: a reverse engineering approach. https://doi.org/10.1101/2021.08.31.458385
Cite the original work for its findings. Save a collection to share your selection of sources.