Search bioRxiv⌕ Search

bioRxiv · 10.1101/2021.05.28.446111

Now you see it, now you don't: optimal parameters for interslice stimulation in concurrent TMS-fMRI

Abstract

The powerful combination of transcranial magnetic stimulation (TMS) concurrent with functional magnetic resonance imaging (fMRI) provides rare insights into the causal relationships between brain activity and behaviour. Despite a recent resurgence in popularity, TMS-fMRI remains technically challenging. Here we examined the feasibility of applying TMS during short gaps between fMRI slices to avoid incurring artefacts in the fMRI data. We quantified signal dropout and changes in temporal signal-to-noise ratio (tSNR) for TMS pulses presented at timepoints from 100ms before to 100ms after slice onset. Up to 3 pulses were delivered per volume using MagVentures MR-compatible TMS coil. We used a spherical phantom, two 7-channel TMS-dedicated surface coils, and a multiband (MB) sequence (factor=2) with interslice gaps of 100ms and 40ms, on a Siemens 3T Prisma-fit scanner. For comparison we repeated a subset of parameters with a more standard single-channel TxRx (birdcage) coil, and with a human participant and surface coil set up. We found that, even at 100% stimulator output, pulses applied at least - 40ms/+50ms from the onset of slice readout avoid incurring artifacts. This was the case for all three setups. Thus, an interslice protocol can be achieved with a frequency of up to ~10 Hz, using a standard EPI sequence (slice acquisition time: 62.5ms, interslice gap: 40ms). Faster stimulation frequencies would require shorter slice acquisition times, for example using in-plane acceleration. Interslice TMS-fMRI protocols provide a promising avenue for retaining flexible timing of stimulus delivery without incurring TMS artifacts.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Scrivener, C. L., Jackson, J. B., Correia, M. M., Mada, M., Woolgar, A.. 2021-05-30. Now you see it, now you don't: optimal parameters for interslice stimulation in concurrent TMS-fMRI. https://doi.org/10.1101/2021.05.28.446111

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Rab10 and Arhgef7 interact to promote axon extension by linking vesicle supply and exocytosis

The formation of functional neural circuits begins with the extension of a single axon by immature neurons. Axon elongation requires an expansion of the plasma membrane that depends on the polarization of vesicle trafficking and exocytosis. It is not completely understood how the increased transport of vesicles into the growing axon is linked to their subsequent insertion into the plasma membrane. An analysis of early stages of neuronal differentiation indicates that an asymmetry in neurite length precedes axon specification and the accumulation of PPVs in the nascent axon. We show that increasing the transport of vesicles in unpolarized neurons is sufficient to promote the extension of additional axons. This effect indicates that an increased supply of vesicles stimulates their subsequent insertion into the membrane to allow neurite growth. The link between vesicle transport and exocytosis is mediated by the interaction of Rab10 with Arhgef7. Rab10 stimulates Arhgef7 activity on PPVs as a GEF for Cdc42b to promote axon extension through exocyst-dependent exocytosis, suggesting that their interaction links the increased supply of PPVs to their exocytosis.

neuroscience↗

Subcellular Spatial Profiling Unveils Links Between Neuritic Plaques with Selective Tau Vulnerability in Alzheimer's Disease

Alzheimer's disease (AD) features widespread extracellular amyloid-{beta} plaques but selective intraneuronal tau accumulation in cortical layers II/III and V, while layer IV remains relatively resistant. Here, we combined subcellular spatial transcriptomics with co-registered A{beta} and pTau immunohistochemistry to determine why neurons exposed to comparable plaque-associated pathology differ in somatic pTau accumulation. Plaque-associated neuritic stress occurred similarly across layers, but layer IV neurons showed attenuated pTau accumulation and reduced somatic expression of a shared neurite-soma stress program involving DCTN1, CALM3, NORAD, and PIN1. Trajectory analysis within layers identified tau-vulnerable and resistant neuronal states implicating calcium signaling, retrograde transport, and lysosomal function. Notably, astrocytic APOE-neuronal LRP1 co-expression increased significantly along the pTau-vulnerable trajectory, and APOE {epsilon}4 was associated with stronger coupling of local plaque pathology to pTau-associated molecular programs. These findings reveal neuronal programs and neuron-glia interactions underlying selective tau vulnerability and resistance in AD, highlighting potential tau-targeting therapeutics.

neuroscience↗

Widespread oscillatory suppression in autism persists in the absence of psychotropic medication.

Purpose: Investigate the neural oscillatory activity associated with autism spectrum disorder (ASD) using electroencephalographic (EEG) recordings in children and adolescents. Compare the corresponding oscillatory power between ASD patients taking psychotropic medication with a drug-naive group. Methods: ASD diagnosis was done using DSM-IV and CARS (Childhood Autism Rating Scale). EEG recordings employed 22 scalp electrodes (10/20 system). ASD vs. neurotypical groups were matched for sex and age (5 females; average age: ~10 years old). We analyzed the resting state (eyes open) EEG power spectrum during ~2-minute recordings. The multitaper FFT method was used to estimate spectral power for the delta, theta, alpha, beta and gamma frequency bands. We pooled together data from several electrodes to compute comprehensive power spectra and assess the oscillatory behavior of macro brain regions. Results: We observed widespread (~4Hz - 20Hz) oscillatory suppression comprising the theta, alpha and beta frequency bands. The most widespread and robust ASD-associated power suppression was in the high theta and alpha bands. Delta and gamma bands showed no significant power change for any of the brain regions studied. Results from a subgroup of patients (N = 9) who never used psychotropics confirmed these findings, indicating that they are not an artifact of medication. Conclusion: Suppression in theta, alpha and beta oscillations may offer insights into the neurophysiological underpinnings of autism and could be used as an accessible and comprehensive tool in ASD diagnosis, regardless of the patients being or not on medication.

neuroscience↗