On the sensitivity analysis of porous finite element models for cerebral perfusion estimation

Abstract

Computational physiological models are promising tools to enhance the design of clinical trials and to assist in decision making. Organ-scale haemodynamic models are gaining popularity to evaluate perfusion in a virtual environment both in healthy and diseased patients. Recently, the principles of verification, validation, and uncertainty quantification of such physiological models have been laid down to ensure safe applications of engineering software in the medical device industry. The present study sets out to establish guidelines for the usage of a three-dimensional steady state porous cerebral perfusion model of the human brain following principles detailed in the verification and validation (V&V 40) standard of the American Society of Mechanical Engineers. The model relies on the finite element method and has been developed specifically to estimate how brain perfusion is altered in ischaemic stroke patients before, during, and after treatments. Simulations are compared with exact analytical solutions and a thorough sensitivity analysis is presented covering every numerical and physiological model parameter. The results suggest that such porous models can approximate blood pressure and perfusion distributions reliably even on a coarse grid with first order elements. On the other hand, higher order elements are essential to mitigate errors in volumetric blood flow rate estimation through cortical surface regions. Matching the volumetric flow rate corresponding to major cerebral arteries is identified as a validation milestone. It is found that inlet velocity boundary conditions are hard to obtain and that constant pressure inlet boundary conditions are feasible alternatives. A one-dimensional model is presented which can serve as a computationally inexpensive replacement of the three-dimensional brain model to ease parameter optimisation, sensitivity analyses and uncertainty quantification. The findings of the present study can be generalised to organ-scale porous perfusion models. The results increase the applicability of computational tools regarding treatment development for stroke and other cerebrovascular conditions.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jozsa, T. I., Padmos, R. M., El-Bouri, W. K., Hoekstra, A. G., Payne, S. J.. 2021-02-18. On the sensitivity analysis of porous finite element models for cerebral perfusion estimation. https://doi.org/10.1101/2021.02.18.431511

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Frequency-Dependent Structural Responses of Amyloid-β Fibrils to Terahertz Pulses: A Nonequilibrium Molecular Dynamics Study

The abnormal aggregation of amyloid proteins into fibrils is closely associated with several neurodegenerative diseases, highlighting the importance of developing effective strategies to modulate fibril structural stability. Here, we employed nonequilibrium molecular dynamics(NEMD) simulations to examine the effects of intense terahertz-to-mid-infrared pulses on three amyloid fibrils (2LMP, 2MXU, and 5OQV), focusing on the combined effects of pulse frequency and electric-field strength. Frequency scans from 0.5 to 60 THz in 0.5 THz steps revealed frequency-dependent losses of {beta}-sheet content, with several common response patterns in these fibrils. Comparisons at 2, 23, 33, and 50 THz showed that pulse-induced changes in secondary structure differed from those in high-temperature controls. Hydrogen-bond analysis showed that total hydrogen-bond counts could partially recover even as interchain hydrogen bonds continued to decrease, with distinct responses among representative chain pairs. We therefore propose a two-threshold electric-field framework for fibril disruption: Eth1 describes the onset of structural perturbation, whereas Eth2 indicates persistent structural loss after the pulse. This framework offers a testable approach for characterizing amyloid structural responses to external fields, although the underlying energy-coupling mechanisms, quantitative thresholds, and long-term recovery require further validation. These findings may provide a theoretical basis for exploring external-field-based strategies to modulate protein aggregation.

biophysics↗

Organised streaming of cerebrospinal fluid in the human third ventricle

Quasi-periodic pressure pulses associated with cardiac and respiratory activity generate reciprocating cerebrospinal fluid (CSF) motion in the human ventricles. Regular waves dominated by the cardiac cycle are overlaid with cycles of low-frequency respiratory waves, the latter to become stronger in forced breathing or even dominated by large successive flushes in NREM sleep. The present study investigates how such waves contribute to residual streaming within the human ventricles. Transient CFD simulations were performed in the third ventricle at varying parameters of frequency, stroke volume and wave-form asymmetry. Increasing the aqueduct peak Reynolds-number, either by small stroke volume and high frequency or large stroke volume at low frequency, transfers the flow from a reversible flow pattern to the formation of clear preferential pathways, alternating between the in- and outflow cycle. The resulting permanent streaming flux across the aqueduct relative to the mean oscillatory flow-rate, i.e. the dimensionless streaming ratio SR follows a rational saturation relation, SR [~] ReAq,peak/(C + ReAq,peak), demonstrating that increasing the peak aqueduct Reynolds number yields diminishing returns and bounds the relative contribution of residual inter-ventricular streaming. These findings demonstrate differences in hydrodynamic organisation in the third ventricle and highlight the importance of this organisation for intraventricular fluid exchange.

biophysics↗

Amyloid stability and condensate material properties independently govern the hnRNPA2 condensate to fibril transition

hnRNPA2 is a component of cellular membraneless organelles many of which contain RNA and RNA-binding proteins (RBPs). RBPs frequently contain low-complexity domains (LCDs) that can also assemble into amyloid fibrils. Fibrils isolated from patients with frontotemporal lobar degeneration contain ordered segments of these LCDs and disease-associated mutations can enhance the homotypic interactions that promote aggregation. Although previous studies have largely examined the condensate-to-fibril transition by altering condensate stability, how amyloid structure governs this process remains poorly understood. Here, we show that the hnRNPA2 LCD forms a reproducible fibril fold and by combining structure-guided thermodynamic profiling, peptide design, mutagenesis and in vitro characterization under conditions with (two-phase) and without (one-phase) condensates, we define the molecular determinants of its assembly. We identify an aromatic triad within the fibril core that controls fibril formation kinetics and thermodynamic stability. Mutational analysis further reveals that condensate stability and fibril stability are largely independent. Finally, microrheology linked reduced condensate viscosity to faster fibril formation, supporting a role for condensate material properties in regulating aggregation kinetics. Together, these findings support a model in which the condensate-to-fibril transition is governed by the interplay between a disordered ''fuzzy coat'' and a fibril-forming aromatic triad within hnRNPA2. This work provides a structural framework for understanding how condensates can transition into amyloid assemblies.

biophysics↗