bioRxiv · 10.1101/2020.12.21.423516
Disinfection of Methicillin-Resistant Staphylococcus aureus, Vancomycin-resistant Enterococcus faecium and Acinetobacter baumannii using Klaran WD array system
Abstract
Healthcare-associated infections (HAIs) are a major burden in healthcare systems. In this study, UVC LEDs emitting radiation from 260-270 nm were evaluated for effectiveness in reducing methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), and Acinetobacter baumannii. The array has four WD LEDs, each with 70mW placed at 7cm from test organism. With 11.76 mJ/cm2, the study obtained 99.99% reduction (log10 reduction factor of 4) against MRSA and VRE. For A. baumannii, 9 mJ/cm2 obtained 99.999% reduction (log10 reduction factor of 5). These results present scientific evidence on how effective UVC LEDs can be used in the fight against HAIs.
Source connections
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Mariita, R. M., Randive, R. V.. 2020-12-21. Disinfection of Methicillin-Resistant Staphylococcus aureus, Vancomycin-resistant Enterococcus faecium and Acinetobacter baumannii using Klaran WD array system. https://doi.org/10.1101/2020.12.21.423516
Cite the original work for its findings. Save a collection to share your selection of sources.