bioRxiv · 10.1101/2020.12.13.422609
Ion mechanism and parameter analysis of anodal-first waveforms for selective stimulation of C-fiber nerves
Abstract
Few investigations have been conducted on selective stimulation of small-radius unmyelinated C nerves (C), which is critical to both recoveries of damaged nerves and pain suppressions. The purpose of this study is to understand how an anodal pulse in an anodal-first stimulation could improve C-selectivity over myelinated nociceptive A{delta} nerves (A{delta}), and further clarify the landscape of the solution space. The Hodgkin-Huxley (HH) model and the Mclntyre-Richardson-Grill (MRG) model were used for modelling C and A{delta}, respectively to analyze the underlying ion dynamics and the influence of relevant stimulation waveforms, including monopolar, polarity-symmetric, and asymmetric pulses. Results showed that polarity-asymmetric waveforms with preceding anodal stimulations benefit C-selectivity most, underlain by the decrease of the potassium ion current of C. The optimal parameters for C-selectivity have been identified in the low frequency band, which will benefit remarkably the designs of nociceptive nerve selective stimulation.
Source connections
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
He, S., Yu, W., Tripanpitak, K., Yoshida, Y., Huang, S., Takamatsu, S.. 2020-12-15. Ion mechanism and parameter analysis of anodal-first waveforms for selective stimulation of C-fiber nerves. https://doi.org/10.1101/2020.12.13.422609