Search bioRxivSearch

bioRxiv · 10.1101/2020.06.15.151076

Segmentation-less, automated vascular vectorization robustly extracts neurovascular network statistics from in vivo two-photon images

Abstract

Recent advances in two-photon microscopy (2PM) have allowed large scale imaging and analysis of blood vessel networks in living mice. However, extracting a network graph and vector representations for vessels remain bottlenecks in many applications. Vascular vectorization is algorithmically difficult because blood vessels have many shapes and sizes, the samples are often unevenly illuminated, and large image volumes are required to achieve good statistical power. State-of-the-art, three-dimensional, vascular vectorization approaches often require a segmented (binary) image, relying on manual or supervised-machine annotation. Therefore, voxel-by-voxel image segmentation is biased by the human annotator or trainer. Furthermore, segmented images oftentimes require remedial morphological filtering before skeletonization or vectorization. To address these limitations, we present a vectorization method to extract vascular objects directly from unsegmented images without the need for machine learning or training. The Segmentation-Less, Automated, Vascular Vectorization (SLAVV) source code in MATLAB is openly available on GitHub. This novel method uses simple models of vascular anatomy, efficient linear filtering, and low-complexity vector extraction algorithms to remove the image segmentation requirement, replacing it with manual or automated vector classification. SLAVV is demonstrated on three in vivo 2PM image volumes of microvascular networks (capillaries, arterioles and venules) in the mouse cortex. Vectorization performance is proven robust to the choice of plasma- or endothelial-labeled contrast, and processing costs are shown to scale with input image volume. Fully-automated SLAVV performance is evaluated on simulated 2PM images of varying quality all based on the large (1.4x0.9x0.6 mm3 and 1.6x108 voxel) input image. Vascular statistics of interest (e.g. volume fraction, surface area density) calculated from automatically vectorized images show greater robustness to image quality than those calculated from intensity-thresholded images. Author summarySamuel Mihelic is a PhD candidate in the Biomedical Engineering Department at the University of Texas at Austin. He graduated from Oregon State University (Chemical Engineering BS, Mathematics BS). He hosts the GitHub repository for the code used in this article: https://github.com/UTFOIL/Vectorization-Public. His research interests are in-vivo neural microvascular image analysis, anatomy, and plasticity. William Sikora graduated with a BS in Computational Biomedical Engineering from The University of Texas at Austin in May 2020. He is working with Dr. Yuan Yang and the Laureate Institute for Brain Research as a PhD student of Biomedical Engineering at the University of Oklahoma in Tulsa, researching the highly non-linear world of neural coupling and its link to common neurological pathologies such as stroke. Ahmed Hassan is a graduate of the University of California, Los Angeles and the University of Texas at Austin with a Bachelor's degree in Microbiology, Immunology, and Molecular Genetics and an MSE/PhD in Biomedical Engineering. His graduate research was concentrated in imaging and instrumentation, and his interests include developing optical and laser systems for neuroimaging, image processing and reconstruction, and advanced image analysis. Michael Williamson earned a BSc (Honours) in Neuroscience in 2016 from the University of Alberta, where he trained with Dr. Fred Colbourne. He is currently a doctoral student at the University of Texas at Austin working in the labs of Drs. Theresa Jones and Michael Drew. Theresa Jones is a Professor in the Department of Psychology and Neuroscience at The University of Texas at Austin. Her laboratory studies plasticity of neural structure and synaptic connectivity following brain damage and injury. Andrew K. Dunn is the Donald J. Douglass Centennial Professor of Engineering in the Department of Biomedical Engineering at The University of Texas at Austin and the Director of the Center for Emerging Imaging Technologies. His research focuses on the development of innovative optical imaging techniques for studying the brain.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mihelic, S., Sikora, W., Hassan, A., Williamson, M., Jones, T., Dunn, A.. 2020-06-16. Segmentation-less, automated vascular vectorization robustly extracts neurovascular network statistics from in vivo two-photon images. https://doi.org/10.1101/2020.06.15.151076

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering