Search bioRxivSearch

bioRxiv · 10.1101/2020.06.02.129742

Online milk composition analysis with an on-farm near-infrared sensor

Abstract

On-farm monitoring of milk composition can support close control of the udder and metabolic health of individual dairy cows. In previous studies, near-infrared (NIR) spectroscopy applied to milk analysis has proven useful for predicting the main components of raw milk (fat, protein, and lactose). In this contribution, we present and evaluate a precise tool for online milk composition analysis on the farm. For each milking, the online analyzer automatically collects and analyses a representative milk sample. The system acquires the NIR transmission spectra of the milk samples in the wavelength range from 960 to 1690 nm and performs a milk composition prediction afterward. Over a testing period of 8 weeks, the sensor collected 1165 NIR transmittance spectra of raw milk samples originating from 36 cows for which reference chemical analyses were performed for fat, protein, and lactose. For the same online sensor system, two calibration scenarios were evaluated: training post-hoc prediction models based on a representative set of calibration samples (n = 319) acquired over the entire testing period, and training real-time prediction models exclusively on the samples acquired in the first week of the testing period (n = 308). The obtained prediction models were thoroughly tested on all the remaining samples not included in the calibration sets (n respectively 846 and 857). For the post-hoc prediction models, this resulted in an overall prediction error (root-mean-squared error of prediction, RMSEP) smaller than 0.08% (all % are in w/w) for milk fat (range 1.5-6.3%), protein (2.6-4.3%) and lactose (4-5.1%), while for the real-time prediction models the RMSEP was smaller than 0.09% for milk fat and lactose, and smaller than 0.11% for protein. The milk lactose predictions could be further improved by taking into account a cow-specific bias. The presented online sensor system using the real-time prediction approach can thus be used for detailed and autonomous on-farm monitoring of milk composition after each individual milking, as its accuracy is well within the ICAR requirements for on-farm milk analyzers and even meet the ICAR standards for laboratory analysis systems for fat and lactose. For this real-time prediction approach, a drift was observed in the predictions, especially for protein. Therefore, further research on the development of online calibration maintenance techniques is required to correct for this model drift and further improve the performance of this sensor system.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Diaz-Olivares, J. A., Adriaens, I., Stevens, E., Saeys, W., Aernouts, B.. 2020-06-03. Online milk composition analysis with an on-farm near-infrared sensor. https://doi.org/10.1101/2020.06.02.129742

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering