Why the middle ear piston prosthesis is not effective enough and how to change it?

Abstract

Piston prostheses of the middle ear do not ensure sufficient audibility of high and low sounds. To find out the reason, the amplitudes of the vibrations for the stapes footplate and the piston end were compared. It was seen that for a given force that oscillates with a low frequency, the amplitude of the piston end was higher than the amplitude of the stapes footplate. This means that the stiffness of the tissue sealing up the piston in the footplate hole is lower than the stiffness of the stapes plate suspension. It was shown that as a result, for the case of the higher frequencies, the amplitude of the piston vibrations drops several times. Next, it was compared a sound propagation in the healthy ear with that in the ear after the stapedotomy. To do it, a previously prepared model of sound propagation in the ear was used. The model is simplified, but it gives all parameters of the sound wave in the cochlear fluid. According to it, a motion of the stapes footplate forms a plane wave, while the piston motion initially gives a wave similar to the spherical one. A part of the spherical wave with the front directed towards the apex forms the primary wave running in the cochlea. However, the rest of this wave has the front directed towards the stapes footplate. This wave part, after a reflection from the stapes footplate, creates a secondary wave that follows the primary wave. A splitting of the wavefront around the edge of the piston end is a source of disruptions in the sound perception. The shift of the secondary wave reduces the power of the primary wave; it disturbs the waving of the basilar membrane and may cause extra noise. To justify it, a graph of the level of the cochlear amplification for the ear with the piston prosthesis was shown. The result compared with a simulation for the healthy ear gave the values 5 dB lower. To remove these drawbacks, it was proposed to place the piston end, not inside the cochlea, but in a guide in the form of a tube ended with a funnel fixed in the hole made in the stapes footplate. The piston was suspended in a guide tube on an O-ring formed of silicone gel. It was shown that when the piston is in the guide, the level of cochlear amplification was the same as that in the healthy ear. Some design details of the new piston guide are given. It enables us to make the new piston prosthesis easily and put it into practice.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gambin, W. L.. 2020-03-05. Why the middle ear piston prosthesis is not effective enough and how to change it?. https://doi.org/10.1101/2020.03.03.975052

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering