Search bioRxivSearch

bioRxiv · 10.1101/2019.12.31.892091

Cell shape, and not 2D migration, predicts ECM-driven 3D cell invasion in breast cancer

Abstract

Metastasis, the leading cause of death in cancer patients, requires the invasion of tumor cells through the stroma in response to migratory cues, such as those provided by the extracellular matrix (ECM). Recent advances in proteomics have led to the identification of hundreds of ECM proteins which are more abundant in tumors relative to healthy tissue. Our goal was to develop a pipeline to easily predict which of these ECM proteins is more likely to have an effect on cancer invasion and metastasis. We evaluated the effect of 4 ECM proteins upregulated in breast tumor tissue in multiple human breast cancer cell lines in 3 assays. We found there was no linear relationship between the 11 cell shape parameters we quantified when cells adhere to ECM proteins and 2D cell migration speed, persistence or 3D invasion. We then used classifiers and partial-least squares regression analysis to identify which metrics best predicted ECM-driven 2D migration and 3D invasion responses. ECM-driven 2D cell migration speed or persistence did not correlate with or predict 3D invasion in response to that same cue. However, cell adhesion, and in particular cell elongation and irregularity accurately predicted the magnitude of ECM-driven 2D migration and 3D invasion in all cell lines. Testing predictions revealed that our models are good at predicting the effect of novel ECM proteins within a given cell line, but that ECM responses are cell-line specific. Overall, our studies identify the cell morphological features that determine 3D invasion responses to individual ECM proteins. This platform will help provide insight into the functional role of ECM proteins abundant tumor tissue and help prioritize strategies for targeting tumor-ECM interactions to treat metastasis. FundingThis work was supported by the National Institutes of Health [R00-CA207866-04 to M.J.O.]; Tufts University [Start-up funds from the School of Engineering to M.J.O.] and funds from NSF REU to A.W. Conflict-of-interest: None. Insight BoxMetastasis, the dissemination of tumor cells, is driven by the interaction of invading tumor cells with their local environment, in particular with the ECM, which provides structure and support to our tissues. This study presents an integrated approach to predict the effect of individual ECM proteins on 3D invasion and metastasis based on simple adhesion assays which quantify cell shape. Machine learning classification and partial-least squares regression models reveal that ECM-driven 2D cell migration metrics are not predictive of 3D invasion, and that cell shape of cells adhered to ECM can predict that proteins effect on 3D invasion. These data provide a pipeline for predicting the effect of ECM proteins on breast cancer cell invasion and metastasis.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Baskaran, J. P., Weldy, A., Guarin, J., Munoz, G., Kotlick, M., Subbiah, N., Wishart, A. L., Peng, Y., Miller, M. A., Cowen, L., Oudin, M.. 2020-01-01. Cell shape, and not 2D migration, predicts ECM-driven 3D cell invasion in breast cancer. https://doi.org/10.1101/2019.12.31.892091

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering