Using force data to self-pace an instrumented treadmill and measure self-selected walking speed

Abstract

BackgroundSelf-selected speed is an important functional index of walking. A self-pacing controller that reliably matches walking speed without additional hardware can be useful for measuring self-selected speed in a treadmill-based laboratory. MethodsWe adapted a previously proposed self-pacing controller for force-instrumented treadmills and validated its use for measuring self-selected speeds. We first evaluated the controllers estimation of subject speed and position from the force-plates by comparing it to those from motion capture data. We then compared five tests of self-selected speed. Ten healthy adults completed a standard 10-meter walk test, a 150-meter walk test, a commonly used manual treadmill speed selection test, a two-minute self-paced treadmill test, and a 150-meter self-paced treadmill test. In each case, subjects were instructed to walk at or select their comfortable speed. We also assessed the time taken for a trial and a survey on comfort and ease of choosing a speed in all the tests. ResultsThe self-pacing algorithm estimated subject speed and position accurately, with root mean square differences compared to motion capture of 0.023 m s-1 and 0.014 m, respectively. Self-selected speeds from both self-paced treadmill tests correlated well with those from the 10-meter walk test (R > 0.93, p < 1 x 10-13). Subjects walked slower on average in the self-paced treadmill tests (1.23 {+/-} 0.27 m s-1) than in the 10-meter walk test (1.32 {+/-} 0.18 m s-1) but the speed differences within subjects were consistent. These correlations and walking speeds are comparable to those from the manual treadmill speed selection test (R = 0.89, p = 3 x 10-11; 1.18 {+/-} 0.24 m s-1). Comfort and ease of speed selection were similar in the self-paced tests and the manual speed selection test, but the self-paced tests required only about a third of the time to complete. Our results demonstrate that these self-paced treadmill tests can be a strong alternative to the commonly used manual treadmill speed selection test. ConclusionsThe self-paced force-instrumented treadmill well adapts to subject walking speed and reliably measures self-selected walking speeds. We provide the self-pacing software to facilitate use by gait researchers and clinicians.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Song, S., Choi, H., Collins, S. H.. 2019-12-19. Using force data to self-pace an instrumented treadmill and measure self-selected walking speed. https://doi.org/10.1101/2019.12.18.870592

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering