Search bioRxivSearch

bioRxiv · 10.1101/059238

3D-Printed Autonomous Capillaric Circuits

Abstract

Capillaric circuits (CCs) are advanced capillary microfluidic devices that move liquids in complex pre-programmed sequences without external pumps and valves-relying instead on microfluidic control elements powered by capillary forces. CCs were thought to require high-precision micro-scale features manufactured by photolithography in a cleanroom, which is slow and expensive. Here we present rapidly and inexpensively 3D-printed autonomous CCs. Molds for CCs were fabricated with a benchtop 3D-printer, Poly(dimethylsiloxane) replicas were made, and fluidic functionality was verified with aqueous solutions. We established design rules for 3D-printed CCs by a combination of modelling and experimentation. The functionality and reliability of 3D-printed trigger valves-an essential fluidic element that stops one liquid until flow is triggered by a second liquid-was tested for different geometries and different solutions. Trigger valves with geometries up to 80-fold larger than cleanroom-fabricated ones were found to function reliably. We designed 3D-printed retention burst valves that encode sequential liquid drainage and delivery using capillary pressure differences encoded by varying valve height and width. Using an electrical circuit analogue of the CC, we established circuit design rules for ensuring strictly sequential liquid delivery. We realized a 3D-printed CC with reservoir volumes 60 times larger than cleanroom-fabricated circuits and autonomously delivered eight liquids in a pre-determined sequence in < 7 min, exceeding the number of sequentially-encoded, self-regulated fluidic delivery events apreviously reported. Taken together, our results demonstrate that 3D-printing enables rapid prototyping of reliable CCs with improved functionality and potential applications in diagnostics, research and education.

Source connections

Explore related subjects

Keep this discovery

BibTeXRIS

Ayokunle O Olanrewaju, Alessandra Robillard, Milad Dagher, David Juncker. 2016-06-15. 3D-Printed Autonomous Capillaric Circuits. https://doi.org/10.1101/059238

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

QTL-guided metabolic engineering of a complex trait

Engineering complex phenotypes for industrial and synthetic biology applications is difficult and often confounds rational design. Bioethanol production from lignocellulosic feedstocks is a complex trait that requires multiple host systems to utilize, detoxify, and metabolize a mixture of sugars and inhibitors present in plant hydrolysates. Here, we demonstrate an integrated approach to discovering and optimizing host factors that impact fitness of Saccharomyces cerevisiae during fermentation of a Miscanthus x giganteus plant hydrolysate. We first used high-resolution Quantitative Trait Loci (QTL) mapping and systematic Bulk Reciprocal Hemizygosity analysis (bRHA) to discover 17 loci that differentiate hydrolysate tolerance between an industrially related (JAY291) and a laboratory (S288C) strain. We then used this data to identify a subset of favorable allelic loci that were most amenable for strain engineering. Guided by this \"genetic blueprint\", and using a dual-guide Cas9-based method to efficiently perform multi-kilobase locus replacements, we engineered an S288C strain with superior hydrolysate tolerance than JAY291. Our methods should be generalizable to engineering any complex trait in S. cerevisiae, as well as other organisms.

Bioengineering

Development of a modular automated system for maintenance and differentiation of adherent human pluripotent stem cells.

Patient-specific induced pluripotent stem cells (iPSCs) have tremendous potential for development of regenerative medicine, disease modelling and drug discovery. However, the processes of reprogramming, maintenance and differentiation are labour intensive and subject to inter-technician variability. To address these issues, we established and optimised protocols to allow for the automated maintenance of reprogrammed somatic cells into iPSCs to enable the large-scale culture and passaging of human pluripotent stem cells (PSCs) using a customized TECAN Freedom EVO. Generation of iPSCs was performed offline by nucleofection followed by selection of TRA-1-60 positive cells using a Miltenyi MultiMACS24 Separator. Pluripotency markers were assessed to confirm pluripotency of the generated iPSCs. Passaging was performed using an enzyme-free dissociation method. Proof of concept of differentiation was obtained by differentiating human PSCs into cells of the retinal lineage. Key advantages of this automated approach are the ability to increase sample size, reduce variability during reprogramming or differentiation, and enable medium to high-throughput analysis of human PSCs and derivatives. These techniques will become increasingly important with the emergence of clinical trials using stem cells.

Bioengineering

An Electrochemistry Study of Cryoelectrolysis in Frozen Physiological Saline

This is the first quantitative study on the fundamental physical and electrochemical processes that occur during cryoelectrolysis. Cryoelectrolysis is a new minimally invasive tissue ablation surgical technique that combines the processes of electrolysis and solid/liquid phase transformation (freezing). We measured the pH front propagation and the changes in resistance in a tissue simulant made of physiological saline gel with a pH dye as a function of the sample temperature in the high subzero range above the eutectic. Results demonstrate that effective electrolysis can occur in a high subzero freezing milieu and that the propagation of the pH front is only weakly dependent on temperature. These observations are consistent with a mechanism involving ionic movement through the concentrated saline solution channels between ice crystals at subfreezing temperatures above the eutectic. The Joule heating in these microchannel may cause local microscopic melting, the observed weak dependence of pH front propagation on temperature, and the large changes in resistance with time. In addition, we observed that the pH front propagation from the anode is more rapid than from the cathode. The explanation is the electro-osmotic flow from the cathode to the anode. The findings in this paper may be of fundamental value for designing future cryoelectrolytic ablation surgery protocols.

Bioengineering