Search bioRxiv⌕ Search

Biology subjects

van Heeswijk, R. B.

Publications and source records attributed to van Heeswijk, R. B..

2 recordsLinked to original sources

Hi-Fi fMRI: High-resolution, fast-sampled and sub-second whole-brain functional MRI at 3T in humans

Functional magnetic resonance imaging (fMRI) is a methodological cornerstone of neuroscience. Most studies measure blood-oxygen-level-dependent (BOLD) signal using echo-planar imaging (EPI), Cartesian sampling, and image reconstruction with a one-to-one correspondence between the number of acquired volumes and reconstructed images. However, EPI schemes are subject to trade-offs between spatial and temporal resolutions. We make strides in overcoming these limitations by measuring BOLD with a gradient recalled echo (GRE) with a 3D radial-spiral phyllotaxis trajectory at a high sampling rate (28.49ms) on standard 3T field strength. The framework enables the reconstruction of 3D signal time courses with whole-brain coverage at simultaneously higher nominal spatial (1mm3) and temporal (up to 250ms) resolutions, as compared to optimized EPI schemes. Additionally, we apply motion correction directly to the k-space raw data, enabling flexible motion-corrected reconstructions; the desired temporal resolution to observe hemodynamic responses can be chosen after scanning. By showing activation in the calcarine sulcus of 20 participants completing an ON-OFF visual paradigm, we demonstrate the reliability of our method for applications in cognitive neuroscience research.

neuroscience↗

Characterization of cardiac-induced noise in R2* maps of the brain

PurposeCardiac pulsation increases the noise level in brain maps of the transverse relaxation rate R2*. Cardiac-induced noise is challenging to mitigate during the acquisition of R2* mapping data because its characteristics are unknown. In this work, we therefore aim to characterize cardiac-induced noise in brain maps of the MRI parameter R2*. MethodsWe designed a sampling strategy to acquire multi-echo 3D data in 12 intervals of the cardiac cycle, monitored with a fingertip pulse-oximeter. We measured the amplitude of cardiac-induced noise in this data and assessed the effect of cardiac pulsation on R2* maps computed across echoes. The area of k-space that contains most of the cardiac-induced noise in R2* maps was then identified. Based on these characteristics, we introduced a tentative sampling strategy that aims to mitigate cardiac-induced noise in R2* maps of the brain. ResultsIn inferior brain regions, cardiac pulsation accounts for R2* variations of up to 3s-1 across the cardiac cycle, i.e. [~]35% of the overall variability. Cardiac-induced fluctuations occur throughout the cardiac cycle, with a reduced intensity during the first quarter of the cycle. 50-60% of the overall cardiac-induced noise is localized near the k-space centre (k < 0.074 mm-1). The tentative cardiac noise mitigation strategy reduced the variability of R2* maps across repetitions by 11% in the brainstem and 6% across the whole brain. ConclusionWe provide a characterisation of cardiac-induced noise in brain R2* maps that can be used as a basis for the design of mitigation strategies during data acquisition.

neuroscience↗