Search bioRxiv⌕ Search

Biology subjects

Zickus, V.

Publications and source records attributed to Zickus, V..

2 recordsLinked to original sources

Fluorescence-lifetime optical electrophysiology in contracting cardiomyocytes

Precise monitoring of cardiac electrophysiology in vitro is crucial to understanding heart function and cardiac disease. However, high-throughput, contact-free methods for directly measuring excitation-contraction coupling remain limited. Here, we introduce a new paradigm for quantitative electrophysiological imaging that combines fluorescence lifetime and intensity information to capture dynamic cardiac signals with high fidelity. We show that lifetime measurements are intrinsically decoupled from motion artifacts and provide calibrated calcium concentration and membrane potential readouts across wide fields of view. Using a gated single-photon avalanche diode camera, we acquire fluorescence lifetime images at up to 200 frames per second with sufficient signal-to-noise ratio such that each frame contains meaningful lifetime information without temporal averaging. This approach yields spatially resolved maps of absolute voltage and calcium values across contracting cardiomyocyte monolayers, revealing heterogeneous cell behaviors within individual assays and uncovering previously unreported dynamics during late-phase repolarization for real-time analysis of excitation-contraction coupling.

bioengineering↗

Wide-field Fluorescence Lifetime Imaging Microscopy with a High-Speed Mega-pixel SPAD Camera

Fluorescence lifetime imaging microscopy (FLIM) is a key technology that provides direct insight into cell metabolism, cell dynamics and protein activity. However, determining the lifetimes of different fluorescent proteins requires the detection of a relatively large number of photons, hence slowing down total acquisition times. Moreover, there are many cases, for example in studies of cell collectives, where wide-field imaging is desired. We report scan-less wide-field FLIM based on a 0.5 Megapixel resolution, time-gated Single Photon Avalanche Diode (SPAD) camera, with acquisition rates up to 1 Hz. Fluorescence lifetime estimation is performed via a pre-trained artificial neural network with 1000-fold improvement in processing times compared to standard least squares fitting techniques. We utilised our system to image HT1080 - human fibrosarcoma cell line as well as Convallaria. The results show promise for real-time FLIM and a viable route towards multi-megapixel fluorescence lifetime images, with a proof-of-principle mosaic image shown with 3.6 megapixels.

bioengineering↗