Optimizing and assessing multichannel TMS focality

BackgroundMultichannel transcranial magnetic stimulation (mTMS) enables electronic steering of induced electric fields across multiple cortical targets without physical coil repositioning, addressing key limitations of conventional single-channel TMS (sTMS). However, determining optimal input currents for focal stimulation remains challenging, and different mTMS systems have not been systematically compared under realistic hardware constraints. ObjectiveTo develop an user-centric framework for optimizing and assessing mTMS focality by introducing a generic optimization algorithm, establishing meaningful quality metrics, and comparing mTMS coil arrays with traditional single-channel TMS across cortical targets. MethodsWe developed a fast optimization framework incorporating target E-field constraints via parametrization of degenerated hyperellipsoids, explicitly integrating current-rate limits, for example from stimulator electronics and coil heating. Using high-resolution finite-element models of nine individual brains, we compared two mTMS designs (5-channel planar and 6/12-channel spherical systems) with standard sTMS figure-of-eight coils through E-field simulations. Three complementary metrics quantified stimulation quality: Focality, Target2Max, and OverstimulatedArea. ResultsDespite using a single optimized placement for all region-of-interest targets, mTMS achieved focality comparable to repositioned single-channel TMS in this in-silico study. For superficial targets, single-channel TMS showed slightly better stimulation, but for deeper cortical targets (>25 mm skin-cortex distance), mTMS performed similarly. More mTMS channels improved focality but required stronger current-rate constraints. The planar design performed better for deeper targets, while spherical designs improved with additional channels. ConclusionmTMS systems demonstrate remarkable performance comparable to standard TMS, enabling efficient multi-target stimulation without repositioning. Our open-source framework provides practical tools for designing and evaluating mTMS systems, supporting goal-directed mTMS development and effective application.

neuroscience↗

Single pointwise samples of electric field on a neuron model cannot predict activation threshold by brain stimulation

BackgroundSome computational models of neural activation by transcranial magnetic stimulation overestimate the electric field (E-field) threshold compared to in vivo measurements. A recent study proposed a statistical method to account for the influence of microscopic perturbations to the E-field. The method, however, relies on the unsubstantiated assumption that thresholds can be predicted by single pointwise samples of the E-field strength along neural cables. ObjectiveWe analyzed neural responses to E-field with microscopic perturbations and demonstrate via theoretical derivation and simulations that neural activation is not determined by pointwise E-field amplitude but rather by spatial integration of the E-field along the neural cable. Therefore, the influence of microscopic E-field perturbations is negligible due to the spatiotemporal filtering by the neural membrane and axoplasm. MethodsWe derive the axial and transmembrane currents in a neural cable for an imposed E-field with microscopic perturbations. We simulate neural activation thresholds of unmyelinated and myelinated axons in two stimulation scenarios and compare thresholds for E-field activation with and without perturbations. ResultsIn the theoretical derivation, the perturbation terms average out to zero on larger spatial scales indicating that they do not influence neural activation thresholds. Simulated thresholds with the E-field spatial perturbations present had negligible differences (< 3.4%) compared to those without. ConclusionSingle point samples of the microscopic E-field on a neural cable cannot predict neural activation thresholds. Neural simulations should be used to determine any influence of the E-field spatial perturbations. The latter, however, are unlikely to account for the difference between experimental and simulated E-field thresholds.

bioengineering↗

Personalized electric field simulations of deformable large TMS coils based on automatic position and shape optimization

BackgroundTranscranial Magnetic Stimulation (TMS) therapies use both focal and unfocal coil designs. Unfocal designs often employ bendable windings and moveable parts, making realistic simulations of their electric fields in inter-individually varying head sizes and shapes challenging. This hampers comparisons of the various coil designs and prevents systematic evaluations of their dose-response relationships. ObjectiveIntroduce and validate a novel method for optimizing the position and shape of flexible coils taking individual head anatomies into account. Evaluate the impact of realistic modeling of flexible coils on the electric field simulated in the brain. MethodsAccurate models of four coils (Brainsway H1, H4, H7; MagVenture MST-Twin) were derived from computed tomography data and mechanical measurements. A generic representation of coil deformations by concatenated linear transformations was introduced and validated. This served as basis for a principled approach to optimize the coil positions and shapes, and to optionally maximize the electric field strength in a region of interest (ROI). ResultsFor all four coil models, the new method achieved configurations that followed the scalp anatomy while robustly preventing coil-scalp intersections on N=1100 head models. In contrast, setting only the coil center positions without shape deformation regularly led to physically impossible configurations. This also affected the electric field calculated in the cortex, with a median peak difference of [~]16%. In addition, the new method outperformed grid search-based optimization for maximizing the electric field of a standard figure 8 coil in a ROI with a comparable computational complexity. ConclusionOur approach alleviates practical hurdles that so far hampered accurate simulations of bendable coils. This enables systematic comparison of dose-response relationships across the various coil designs employed in therapy. HighlightsO_LIautomatic positioning and shape optimization of large deformable TMS coils C_LIO_LIensures adherence to the head anatomy and prevents coil-head intersections C_LIO_LIenable automatic electric field maximization in target brain regions C_LIO_LIoutperforms grid search for standard flat coils C_LIO_LIprovides accurate computational models of four coils used in clinical practice C_LI

neuroscience↗

A Leadfield-Free Optimization Framework for Transcranially Applied Electric Currents

BackgroundTranscranial Electrical Stimulation (TES), Temporal Interference Stimulation (TIS), Electroconvulsive Therapy (ECT) and Tumor Treating Fields (TTFields) are based on the application of electric current patterns to the brain. ObjectiveThe optimal electrode positions, shapes and alignments for generating a desired current pattern in the brain vary between persons due to anatomical variability. The aim is to develop a flexible and efficient computational approach to determine individually optimal montages based on electric field simulations. MethodsWe propose a leadfield-free optimization framework that allows the electrodes to be placed freely on the head surface. It is designed for the optimization of montages with a low to moderate number of spatially extended electrodes or electrode arrays. Spatial overlaps are systematically prevented during optimization, enabling arbitrary electrode shapes and configurations. The approach supports maximizing the field intensity in target region-of-interests (ROI) and optimizing for a desired focality-intensity tradeoff. ResultsWe demonstrate montage optimization for standard two-electrode TES, focal center-surround TES, TIS, ECT and TTFields. Comparisons against reference simulations are used to validate the performance of the algorithm. The system requirements are kept moderate, allowing the optimization to run on regular notebooks and promoting its use in basic and clinical research. Conclusion(s)The new framework complements existing optimization methods that require small electrodes, a predetermined discretization of the electrode positions on the scalp and work best for multi-channel systems. It strongly extends the possibilities to optimize electrode montages towards application-specific aims and supports researchers in discovering innovative stimulation schemes. The framework is available in SimNIBS.

neuroscience↗

Fast FEM-based Electric Field Calculations for Transcranial Magnetic Stimulation

ObjectiveTo provide a Finite-Element Method (FEM) for rapid, repeated evaluations of the electric field induced by transcranial magnetic stimulation (TMS) in the brain for changing coil positions. ApproachPreviously, we introduced a first-order tetrahedral FEM enhanced by super- convergent patch recovery (SPR), striking a good balance between computational efficiency and accuracy (Saturnino et al 2019 J. Neural Eng. 16 066032). In this study, we refined the method to accommodate repeated simulations with varying TMS coil position. Starting from a fast direct solver, streamlining the pre- and SPR-based post-calculation steps using weight matrices computed during initialization strongly improved the computational efficiency. Additional speedups were achieved through efficient multi-core and GPU acceleration, alongside the optimization of the volume conductor model of the head for TMS. Main ResultsFor an anatomically detailed head model with [~]4.4 million tetrahedra, the optimized implementation achieves update rates above 1 Hz for electric field calculations in bilateral gray matter, resulting in a 60-fold speedup over the previous method with identical accuracy. An optimized model without neck and with adaptive spatial resolution scaled in dependence to the distance to brain grey matter, resulting in [~]1.9 million tetrahedra, increased update rates up to 10 Hz, with [~]3% numerical error and [~]4% deviation from the standard model. Region-of-interest (ROI) optimized models focused on the left motor, premotor and dorsolateral prefrontal cortices reached update rates over 20 Hz, maintaining a difference of <4% from standard results. Our approach allows efficient switching between coil types and ROI during runtime which greatly enhances the flexibility. SignificanceThe optimized FEM enhances speed, accuracy and flexibility and benefits various applications. This includes the planning and optimization of coil positions, pre-calculation and training procedures for real-time electric field simulations based on surrogate models as well as targeting and dose control during neuronavigated TMS.

neuroscience↗