Search bioRxiv⌕ Search

Biology subjects

Wilkins, R.

Publications and source records attributed to Wilkins, R..

2 recordsLinked to original sources

Automated Cytogenetic Biodosimetry at Population-Scale

IntroductionThe dicentric chromosome (DC) assay accurately quantifies exposure to radiation, however manual and semi-automated assignment of DCs has limited its use for a potential large-scale radiation incident. The Automated Dicentric Chromosome Identifier and Dose Estimator Chromosome (ADCI) software automates unattended DC detection and determines radiation exposures, fulfilling IAEA criteria for triage biodosimetry. We present high performance ADCI (ADCI-HT), with the requisite throughput to stratify exposures of populations in large scale radiation events.\n\nMethodsADCI-HT streamlines dose estimation by optimal scheduling of DC detection, given that the numbers of samples and metaphase cell images in each sample vary. A supercomputer analyzes these data in parallel, with each processor handling a single image at a time. Processor resources are managed hierarchically to maximize a constant stream of sample and image analysis. Metaphase data from populations of individuals with clinically relevant radiation exposures after simulated large nuclear incidents were analyzed. Sample counts were derived from US Census data. Analysis times and exposures were quantified for 15 different scenarios.\n\nResultsProcessing of metaphase images from 1,744 samples (500 images each) used 16,384 CPUs and was completed in 1hr 11min 23sec, with radiation dose of all samples determined in 32 sec with 1,024 CPUs. Processing of 40,000 samples with varying numbers of metaphase cells, 10 different exposures from 5 different biodosimetry labs met IAEA accuracy criteria (dose estimate differences were < 0.5 Gy; median = 0.07) and was completed in ~25 hours. Population-scale metaphase image datasets within radiation contours of nuclear incidents were defined by exposure levels (either >1 Gy or >2 Gy). The time needed to analyze samples of all individuals receiving exposures from a high yield airborne nuclear device ranged from 0.6-7.4 days, depending on the population density.\n\nConclusionADCI-HT delivers timely and accurate dose estimates in a simulated population-scale radiation incident.

bioinformatics↗

Accurate Cytogenetic Biodosimetry Through Automation Of Dicentric Chromosome Curation And Metaphase Cell Selection

Software to automate digital pathology relies on image quality and the rates of false positive and negative objects in these images. Cytogenetic biodosimetry detects dicentric chromosomes (DCs) that arise from exposure to ionizing radiation, and determines radiation dose received from the frequency of DCs. We present image segmentation methods to rank high quality cytogenetic images and eliminate suboptimal metaphase cell data based on novel quality measures. Improvements in DC recognition increase the accuracy of dose estimates, by reducing false positive (FP) DC detection. A set of chromosome morphology segmentation methods selectively filtered out false DCs, arising primarily from extended prometaphase chromosomes, sister chromatid separation and chromosome fragmentation. This reduced FPs by 55% and was highly specific to the abnormal structures ([&ge;]97.7%). Additional procedures were then developed to fully automate image review, resulting in 6 image-level filters that, when combined, selectively remove images with consistently unparsable or incorrectly segmented chromosome morphologies. Overall, these filters can eliminate half of the FPs detected by manual image review. Optimal image selection and FP DCs are minimized by combining multiple feature based segmentation filters and a novel image sorting procedure based on the known distribution of chromosome lengths. Applying the same segmentation filtering procedures to both calibration and test sample image data reduced the average dose estimation error from 0.4Gy to <0.2Gy, obviating the need to first manually review these images. This reliable and scalable solution enables batch processing multiple samples of unknown dose, and meets current requirements for triage radiation biodosimetry of high quality metaphase cell preparations.

genetics↗