Search bioRxiv⌕ Search

Biology subjects

Wilhelmy, F.

Publications and source records attributed to Wilhelmy, F..

6 recordsLinked to original sources

Real-time posterior probabilistic TMS motor mapping with robust individualized stopping criteria

Background. Electric-field-informed regression provides high-resolution transcranial magnetic stimulation (TMS) motor maps, but conventional nonlinear fitting is too slow to update the map during acquisition, so sessions rely on predefined stimulation budgets, despite substantial inter-individual variability in the data required for stable localization. Objective. To develop a real-time analysis updating a posterior probability map between pulses and compare its hotspots with finger-tapping functional MRI (fMRI). Methods. We analyzed two independent cohorts (12 and 13 participants, one newly collected), analyzing each hand muscle independently. We replaced the conventional per-element sigmoid fit with Spearman's rank correlation coefficient and transformed the resulting score map into a posterior probability map using marginal-likelihood evidence. Acquisition stopped once posterior mass within 5 mm of the hotspot passed a preset confidence level. Results. The Spearman and linear scores updated the region of interest within milliseconds, versus tens of seconds for sigmoid fitting. Spearman more closely matched the full-data sigmoid hotspot in recorded sessions and converged faster and more precisely to the true source in virtual subjects. Across both fast scores, at a confidence level of 0.85, the stopping criterion was met after a median of 74-159 pulses, with 26-454 across individual problems. FDI hotspots lay 8.3 {+/-} 4.3 mm from the fMRI center of gravity, in the precentral hand region. Conclusions. Rank correlation reduces computation time without loss of accuracy relative to sigmoid fitting. The resulting posterior probability map provides a session-specific stopping criterion in place of a fixed pulse budget.

neuroscience↗

An Approach to Measure Conductivity Gradients of Brain Tissue Transitions using Electrode Arrays

Accurate determination of surgical margins is critical in tumor resection to ensure complete removal of tumor-infiltrated tissue while preserving healthy tissue. Pathological assessment provides reliable information but is time-consuming. This study investigates the feasibility of using impedance spectroscopy to detect tissue transitions at a macroscopic level. Two electrode arrays--one-dimensional and two-dimensional--were applied to ex vivo porcine brain tissue. Measurements were performed using both two- and four-electrode configurations, and data were corrected using the multiple-load compensation method. Results demonstrate that the one-dimensional array provides continuous conductivity profiles corresponding to tissue transitions, while the two-dimensional array showed less consistent results. These findings suggest that impedance spectroscopy is a promising tool for intraoperative margin detection, but further optimization of electrode geometry and measurement data processing is required.

neuroscience↗

A 4-pole Theory-Based Compensation Method using Multiple Loads for Impedance Spectroscopy of Porcine Brain Tissue

Accurate determination of the electrical properties of brain tissue--conductivity and relative permittivity--is essential for modeling and optimizing neurostimulation and neuroimaging and modulation techniques such as EEG, MEG, TMS, and TES. However, large discrepancies in reported conductivity values highlight the methodological challenges associated with impedance measurements. In this study, we present a systematic evaluation of compensation methods in impedance spectroscopy to improve measurement accuracy using a self-developed four-point platinum electrode designed for biological tissue applications. Three compensation algorithms--open-short, open-short-load, and multiple-load--were implemented and compared using an RC parallel test circuit that emulated typical measurement conditions, with load resistances ranging from 250 {Omega} to 5000 {Omega}. Quantitative error analysis demonstrated that the multiple-load method achieved the lowest normalized root mean square error (3.4%) and superior stability across frequencies from 100 Hz to 1 MHz. The calibrated probe was subsequently applied to post mortem porcine brain tissue, yielding conductivity values of grey matter of 0.109 S/m and white matter of 0.074 S/m. These results are significantly lower than standard simulation parameters of 0.275 S/m, and 0.126 S/m for grey and white matter, respectively. Finite-element simulations revealed that using the measured conductivities increased electric field predictions by 2.1% for TMS and 46% for TES in the maximum electric field magnitude, respectively. Our findings demonstrate that accurate impedance compensation is critical for reliable characterization of brain tissue and for enhancing the precision of neurostimulation modeling in the future.

neuroscience↗

Effect of contact pressure on porcine postmortem brain tissue impedance

In this experimental study we demonstrate the influence of contact pressure on porcine postmortem brain tissue impedance using a movable electrode array and a load cell. We show that the variation of the contact pressure between the tissue and the measurement probe leads to a coefficient of variation in the measured impedance of under 3%. Its influence can therefore be neglected. Further, we fit the measured impedances to an equivalent circuit model and compare the resistance as well as the cell density of grey and white matter brain tissue based on the model parameters.

neuroscience↗

A four-point measurement probe for brain tissue conductivity and permittivity characterization

We present a measurement probe consisting of four platinum electrodes fused into soda-lime glass. The probe is based on a four-terminal sensing technique that uses separate pairs of current-carrying and voltage-sensing electrodes and performs more accurate measurements than the simpler and more usual two-terminal sensing technique. The electrodes are aranged within an area of 1 mm2 allowing for local characterization of different brain tissues. The operation of the probe is demonstrated in situ on post mortem porcine brain tissue by measuring the impedance spectra of grey and white matter in a frequency range of 1 kHz < f < 1 MHz. The conductivity and relative permittivity are derived from the impedance spectra using the geometry factor of the probe. The geometry factor is obtained experimentally by measuring the impedances of an electrolytical dilution series with known conductivities. The obtained conductivity of grey matter is in the order of 0.11 S/m and of white matter is in the order of 0.07 S/m over the acquired frequency range.

neuroscience↗

In situ impedance measurements on postmortem porcine brain

The paper presents an experimental study where the distinctness of grey and white matter of an in situ postmortem porcine brain by impedance measurements is investigated. Experimental conditions that would allow to conduct the same experiment on in vivo human brain tissue are replicated. https://doi.org/10.1515/cdbme-2019-XXXX

neuroscience↗