Search bioRxiv⌕ Search

Biology subjects

Weiss, J. A.

Publications and source records attributed to Weiss, J. A..

7 recordsLinked to original sources

A Computational Framework to Optimize the Mechanical Behavior of Synthetic Vascular Grafts

The failure of synthetic small-diameter vascular grafts has been attributed to a mismatch in the compliance between the graft and native artery, driving mechanisms that promote thrombosis and neointimal hyperplasia. Additionally, the buckling of grafts results in large deformations that can lead to device failure. Although design features can be added to lessen the buckling potential, the addition is detrimental to decreasing compliance (e.g., reinforcing coil). Herein, we developed a novel finite element framework to inform vascular graft design by evaluating compliance and resistance to buckling. A batch-processing scheme iterated across the multi-dimensional design parameter space, which included three parameters: coil thickness, modulus, and spacing. Three types of finite element models were created in FEBio for each unique coil-reinforced graft parameter combination to simulate pressurization, axial buckling, and bent buckling, and results were analyzed to quantify compliance, buckling load, and kink radius, respectively, from each model. Importantly, model validation demonstrated that model predictions agree qualitatively and quantitatively with experimental observations. Subsequently, data for each design parameter combination were integrated into an optimization function for which a minimum value was sought. The optimization values identified various candidate graft designs with promising mechanical properties. Our investigation successfully demonstrated the model-directed framework identified vascular graft designs with optimal mechanical properties, which can potentially improve clinical outcomes by addressing device failure. In addition, the presented computational framework promotes model-directed device design for a broad range of biomaterial and regenerative medicine strategies.

bioengineering↗

Targeting Damaged Collagen for Intra-Articular Delivery of Therapeutics using Collagen Hybridizing Peptides

The objective of this study was to investigate the potential of collagen hybridizing peptides (CHPs), which bind to denatured collagen, to extend the retention time of near-infrared fluorophores (NIRF) following intra-articular (IA) injection in rat knee joints. CHPs were synthesized with a NIRF conjugated to N-terminus. Male Sprague-Dawley rats were assigned to one of four experimental groups: healthy, CHP; osteoarthritis (OA), CHP; healthy, scrambled-sequence CHP (sCHP), which has no collagen binding affinity; or OA, sCHP. Animals in the OA groups received an IA injection of monosodium iodoacetate to induce OA. All animals then received the corresponding CHP injection. Animals were imaged repeatedly over two weeks using an in vivo fluorescence imaging system. Joint components were isolated and imaged to determine CHP binding distribution. Safranin-O and Fast Green histological staining was performed to confirm the development of OA. CHPs were found to be retained within the joint following IA injection in both healthy and OA animals for the full study period. In contrast, sCHPs were cleared within 24-48 hours. CHP signal was significantly greater (p<0.05) in OA joints when compared to healthy joints. At the two-week end point, multiple joint components retained CHPs, including cartilage, meniscus, and synovium. CHPs extended the retention time of NIRFs following IA injection in healthy and OA knee joints by binding to multiple collagenous tissues in the joint. These results support the pursuit of further research on CHP based therapeutics for IA treatment of OA.

bioengineering↗

CRISPRi-Driven Osteogenesis in Adipose-Derived Stem Cells for Bone Healing and Tissue Engineering

Engineered bone tissue synthesized from mesenchymal stem cell progenitors has numerous applications throughout the fields of regenerative medicine and tissue engineering. However, these multipotent cells offer little tissue-building assistance without differentiation direction from environmental cues such as bone morphogenetic proteins (BMPs). Unfortunately, BMP dosing and environmental cues can be difficult to control both in vitro and after in vivo delivery. Several BMP antagonists are expressed by cells in response to BMP dosing that bind extracellular BMPs and reduce their effective concentration. Here, we use CRISPR-guided gene-modulation technology to downregulate the expression of three BMP antagonists, noggin, gremlin-1, and gremlin-2, in adipose-derived stem cells (ASCs). We show that regulating noggin using this method results in ASC osteogenesis without the need for exogenous growth factors. To demonstrate the versatility and the precision capabilities of these engineered cells, we employ them with CRISPRa multiplex-engineered chondrogenic cells as a proof-of-concept tissue engineering application by creating a tissue gradient similar to the fibrocartilage-to-mineralized-fibrocartilage gradient in the tendon/ligament enthesis or intervertebral disc attachment. In doing so, we show that multiple CRISPR multiplex engineered cell types can be utilized in concert to provide a high degree of tissue developmental control without the use of exogenous growth factors.

bioengineering↗

Mechanics of lung cancer: A finite element model shows strain amplification during early tumorigenesis

Early lung cancer lesions develop within a unique microenvironment that undergoes constant cyclic stretch from respiration. While tumor stiffening is an established driver of tumor progression, the contribution of stress and strain to lung cancer is unknown. We developed tissue scale finite element models of lung tissue to test how early lesions alter respiration-induced strain. We found that an early tumor, represented as alveolar filling, amplified the strain experienced in the adjacent alveolar walls. Tumor stiffening further increased the amplitude of the strain in the adjacent alveolar walls and extended the strain amplification deeper into the normal lung. In contrast, the strain experienced in the tumor proper was less than the applied strain, although regions of amplification appeared at the tumor edge. Measurements of the alveolar wall thickness in clinical and mouse model samples of lung adenocarcinoma (LUAD) showed wall thickening adjacent to the tumors, consistent with cellular response to strain. Modeling alveolar wall thickening by encircling the tumor with thickened walls moved the strain amplification radially outward, to the next adjacent alveolus. Simulating iterative thickening in response to amplified strain produced tracks of thickened walls. We observed such tracks in early-stage clinical samples. The tracks were populated with invading tumor cells, suggesting that strain amplification in very early lung lesions could guide pro-invasive remodeling of the tumor microenvironment. The simulation results and tumor measurements suggest that cells at the edge of a lung tumor and in surrounding alveolar walls experience increased strain during respiration that could promote tumor progression. Author SummaryLung cancer is the leading cause of cancer-related death in the world. Efforts to identify and treat patients early are hampered by an incomplete understanding of the factors that drive early lesion progression to invasive cancer. We aimed to understand the role of mechanical strain in early lesion progression. The lung is unique in that it undergoes cyclic stretch, which creates strain across the alveolar walls. Computational models have provided fundamental insights into the stretch-strain relationship in the lung. In order to map the strain experienced in the alveolar walls near a tumor, we incorporated a tumor into a tissue scale model of the lung under stretch. We used finite element modeling to apply physiological material behavior to the lung and tumor tissue. Based on reported findings and our measurements, tumor progression was modeled as stiffening of the tumor and thickening of the tumor-adjacent alveolar walls. We found that early tumors amplified the strain in the tumor-adjacent alveolar walls. Strain amplification also arose at the tumor edges. Simulating strain-mediated wall stiffening generated tracks of thickened walls. We experimentally confirmed the presence of tracks of thickened extracellular matrix in clinical samples of LUAD. Our model is the first to interrogate the alterations in strain in and around a tumor during simulated respiration and suggests that lung mechanics and strain amplification play a role in early lung tumorigenesis.

cancer biology↗

Effects of osteogenic ambulatory mechanical stimulation on early stages of BMP-2mediated bone repair

Mechanical loading of bone defects through rehabilitation is a promising therapeutic approach to stimulate repair and reduce the risk of non-union; however, little is known about how therapeutic mechanical stimuli modulate early stages of repair before mineralized bone formation. In a previous study, we established an osteogenic mechanical loading protocol using early ambulatory rehabilitation and a compliant, load-sharing fixator in a rat model of BMP-2 mediated bone defect repair. The objective of this study was to investigate the early effects of osteogenic loading on cytokine expression, tissue composition, and angiogenesis during the first 3 weeks of repair in this model. Using a wireless implantable strain sensor for local measurements of mechanical boundary conditions, finite element simulations showed that osteogenic mechanical loading increased mean compressive strain in defect soft tissue during rehabilitative ambulation at 1 week (load-sharing: -1.54 {+/-} 0.17% vs. load-shielded: -0.76 {+/-} 0.06%), and that strain was amplified in remaining soft tissue regions at 3 weeks as mineralization progressed (load-sharing: -1.89 {+/-} 0.35% vs. load-shielded: -1.38 {+/-} 0.35%). Multivariate analysis of multiplex cytokine arrays revealed that loading significantly altered cytokine expression profiles in the defect tissue at 2 weeks compared to load-shielded defects. Specifically, loading reduced VEGF and increased CXCL5 (LIX) levels. Subsequently, vascular volume in loaded defects was reduced relative to load-shielded defects but similar to intact bone at 3 weeks. Endochondral bone repair was also observed histologically in loaded defects only at 3 weeks. Together, these results demonstrate that moderate ambulatory strains previously shown to stimulate functional bone regeneration significantly alter early angiogenic and cytokine signaling and may promote endochondral ossification in large segmental bone defects. Authors ContributionsB.S.K., N.J.W., and R.E.G. designed the research and performed surgeries; B.S.K., C.E.V., and J.K. performed experiments; B.S.K., C.E.V., J.K., and L.B.W., analyzed data; B.S.K., C.E.V., N.J.W., and R.E.G. wrote the manuscript; All authors interpreted data, critically edited, and have read and approved the final manuscript.

bioengineering↗

Mechanical Regulation of Microvascular Angiogenesis

Neovascularization is a critical early step toward successful tissue regeneration during wound healing. While vasculature has long been recognized as highly mechanosensitive (to fluid shear, pulsatile luminal pressure, etc.), the effects of extracellular matrix strains on angiogenesis are poorly understood. Previously, we found that dynamic matrix compression in vivo potently regulated neovascular growth during tissue regeneration; however, whether matrix deformations directly regulate00 angiogenesis remained unknown. Here, we tested the effects of load initiation time, strain magnitude, and mode of compressive deformation (uniform compression vs. compressive indentation that also introduced shear stress) on neovascularization and key angiogenic and mechanotransduction signaling pathways by microvascular fragments in vitro. We hypothesized that neovascularization would be enhanced by delayed, moderate compression and inhibited by early, high magnitude compression and by compressive indentation. Consistent with our hypothesis, early, high magnitude loading inhibited vessel growth, while delayed loading enhanced vessel growth. Compressive indentation led to longer, more branched networks than uniform compression - particularly at high strain magnitude. Gene expression was differentially regulated by time of load initiation; genes associated with active angiogenic sprouts were downregulated by early loading but upregulated by delayed loading. Canonical gene targets of the YAP/TAZ mechanotransduction pathway were increased by loading and abrogated by pharmacological YAP inhibition. Together, these data demonstrate that neovascularization is directly responsive to dynamic matrix strain and is particularly sensitive to the timing of load initiation. This work further identifies putative mechanoregulatory angiogenic mechanisms and implicates a critical role for dynamic mechanical cues in vascularized tissue regeneration. Statement of SignificanceMechanical cues influence tissue regeneration, and although vasculature is known to be mechanically sensitive, remarkably little is known about the effects of bulk extracellular matrix deformation on the nascent vessel networks found in healing tissues. Here, we demonstrated that load initiation time, magnitude, and mode all regulate microvascular growth, as well as upstream angiogenic and mechanotransduction signaling pathways. Across all tested magnitudes and modes, microvascular network formation and upstream signaling were powerfully regulated by the timing of load initiation. This work provides a new foundational understanding of how extracellular matrix mechanics regulate angiogenesis and has critical implications for clinical translation of new regenerative medicine therapies and physical rehabilitation strategies designed to enhance revascularization during tissue regeneration.

bioengineering↗

Microplate Assay for Denatured Collagen using CollagenHybridizing Peptides

The purpose of this study was to develop a microplate assay for quantifying denatured collagen by measuring the fluorescence of carboxyfluorescein bound collagen hybridizing peptides (F-CHP). We have shown that F-CHP binds selectively with denatured collagen, and that mechanical overload of tendon fascicles causes collagen denaturation. Proteinase K was used to homogenize tissue samples after F-CHP staining, allowing fluorescence measurement using a microplate reader. We compared our new assay to our previous image analysis method and the trypsin-hydroxyproline assay, which is the only other available method to directly quantify denatured collagen. Relative quantification of denatured collagen was performed in rat tail tendon fascicles subjected to incremental tensile overload, and normal and ostoeoarthritic guinea pig cartilage. In addition, the absolute amount of denatured collagen was determined in rat tail tendon by correlating F-CHP fluorescence with percent denatured collagen as determined by the trypsin-hydroxyproline assay. Rat tail tendon fascicles stretched to low strains (<7.5%) exhibited minimal denature collagen, but values rapidly increased at medium strains (7.5-10.5%) and plateaued at high strains ([&ge;]12%). Osteoarthritic cartilage had higher F-CHP fluorescence than healthy cartilage. Both of these outcomes are consistent with previous studies. With the calibration curve, the microplate assay was able to absolutely quantify denatured collagen in mechanically damaged rat tail tendon fascicles as reliably as the trypsin-hydroxyproline assay. Further, we achieved these results more efficiently than current methods in a rapid, high-throughput manner, with multiple types of collagenous tissue while maintaining accuracy.

bioengineering↗