Search bioRxiv⌕ Search

Biology subjects

Weiskopf, N.

Publications and source records attributed to Weiskopf, N..

At least 37 records · Page 2Linked to original sources

Laminar CBV and BOLD response-characteristics over time and space in the human primary somatosensory cortex at 7T

Uncovering the cortical representation of the body has been at the core of human brain mapping for decades, with special attention given to the digits. In the last decade, advances in functional magnetic resonance imaging (fMRI) technologies have opened the possibility of noninvasively unraveling the 3rd dimension of digit representations in humans along cortical layers. In laminar fMRI it is common to combine the use of the highly sensitive blood oxygen level dependent (BOLD) contrast with cerebral blood volume sensitive measurements, like vascular space occupancy (VASO), that are more specific to the underlying neuronal populations. However, the spatial and temporal VASO response characteristics across cortical depth to passive stimulation of the digits are still unknown. Therefore, we characterized haemodynamic responses to vibrotactile stimulation of individual digit-tips across cortical depth at 0.75 mm in-plane spatial resolution using BOLD and VASO fMRI at 7T. We could identify digit-specific regions of interest (ROIs) in putative Brodmann area 3b, following the known anatomical organization. In the ROIs, the BOLD response increased towards the cortical surface due to the draining vein effect, while the VASO response was more shifted towards middle cortical layers, likely reflecting bottom-up input from the thalamus, as expected. Interestingly, we also found slightly negative BOLD and VASO responses for non-preferred digits in the ROIs, potentially indicating neuronal surround inhibition. Finally, we explored the temporal signal dynamics for BOLD and VASO as a function of distance from activation peaks resulting from stimulation of contralateral digits. With this analysis, we showed a triphasic response consisting of an initial peak and a subsequent negative deflection during stimulation, followed by a positive post-stimulus response in BOLD and to some extent in VASO. While similar responses were reported with invasive methods in animal models, here we demonstrate a potential neuronal excitation-inhibition mechanism in a center-surround architecture across layers in the human somatosensory cortex. Given that, unlike in animals, human experiments do not rely on anesthesia and can readily implement extensive behavioral testing, obtaining this effect in humans is an important step towards further uncovering the functional significance of the different aspects of the triphasic response.

neuroscience↗

Connectivity at fine scale: mapping structural connective fields by tractography of short association fibres in vivo

The extraordinary number of short association fibres (SAF) connecting neighbouring cortical areas is a prominent feature of the large gyrified human brain. The contribution of SAF to the human connectome is largely unknown because of methodological challenges in mapping them. We present a method to characterise cortico-cortical connectivity mediated by SAF in topologically organised cortical areas. We introduce the structural connective fields (sCF) metric which specifically quantifies neuronal signal propagation and integration mediated by SAF. This new metric complements functional connective field metrics integrating across contributions from short- and long-range white matter and intracortical fibres. Applying the method in the human early visual processing stream, we show that SAF preserve cortical functional topology. Retinotopic maps of V2 and V3 could be predicted from retinotopy in V1 and SAF connectivity. The sCF sizes increased along the cortical hierarchy and were smaller than their functional counterparts, in line with the latter being additionally broadened by long-range and intracortical connections. In vivo sCF mapping provides insights into short-range cortico- cortical connectivity in humans comparable to tract tracing studies in animal research and is an essential step towards creating a complete human connectome. HighlightsO_LINon-invasive mapping of Short Association Fibre (SAF) connectivity via diffusion-weighted MRI-based probabilistic tractography accurately predicted cortical functional neuroanatomy. C_LIO_LIThe novel structural Connective Fields (sCF) concept provides a quantitative measure of cortico-cortical integration facilitated by SAF, complementing the existing functional Connective Field (CF) concept. C_LIO_LISub-millimeter resolution diffusion-weighted MRI enables tractography and connective field modeling of SAF, unlocking applications previously restricted to invasive tract tracing in animal studies. C_LI

neuroscience↗

Characterisation of laminar and vascular spatiotemporal dynamics of CBV and BOLD signals using VASO and ME-GRE at 7T in humans

Interpretation of cortical laminar functional magnetic resonance imaging (fMRI) activity requires detailed knowledge of the spatiotemporal haemodynamic response across vascular compartments due to the well-known vascular biases (e.g. the draining veins). Further complications arise from the spatiotemporal hemodynamic response that differs depending on the duration of stimulation. This information is crucial for future studies using depth-dependent cerebral blood volume (CBV) measurements, which promise higher specificity for the cortical microvasculature than the blood oxygenation level dependent (BOLD) contrast. To date, direct information about CBV dynamics with respect to stimulus duration, cortical depth and vasculature is missing in humans. Therefore, we characterized the cortical depth-dependent CBV-haemodynamic responses across a wide set of stimulus durations with 0.9 mm isotropic spatial and 0.785 seconds effective temporal resolution in humans using slice-selective slabinversion vascular space occupancy (SS-SI VASO). Additionally, we investigated signal contributions from macrovascular compartments using fine-scale vascular information from multiecho gradient-echo (ME-GRE) data at 0.35 mm isotropic resolution. In total, this resulted in >7.5h of scanning per participant (n=5). We have three major findings: (I) While we could demonstrate that 1 second stimulation is viable using VASO, more than 12 seconds stimulation provides better CBV responses in terms of specificity to microvasculature, but durations beyond 24 seconds of stimulation may be wasteful for certain applications. (II) We observe that CBV responses show dilation patterns across the cortex. (III) While we found increasingly strong BOLD signal responses in vessel-dominated voxels with longer stimulation durations, we found increasingly strong CBV signal responses in vessel-dominated voxels only until 4 second stimulation durations. After 4 seconds, only the signal from non-vessel dominated voxels kept increasing. This might explain why CBV responses are more specific to the underlying neuronal activity for long stimulus durations.

neuroscience↗

Reliability of task-based fMRI in the dorsal horn of the human spinal cord

The application of functional magnetic resonance imaging (fMRI) to the human spinal cord is still a relatively small field of research and faces many challenges. Here we aimed to probe the limitations of task-based spinal fMRI at 3T by investigating the reliability of spinal cord blood oxygen level dependent (BOLD) responses to repeated nociceptive stimulation across two consecutive days in 40 healthy volunteers. We assessed the test-retest reliability of subjective ratings, autonomic responses, and spinal cord BOLD responses to short heat pain stimuli (1s duration) using the intraclass correlation coefficient (ICC). At the group level, we observed robust autonomic responses as well as spatially specific spinal cord BOLD responses at the expected location, but no spatial overlap in BOLD response patterns across days. While autonomic indicators of pain processing showed good-to-excellent reliability, both {beta}-estimates and z-scores of task-related BOLD responses showed poor reliability across days in the target region (gray matter of the ipsilateral dorsal horn). When taking into account the sensitivity of gradient-echo echo planar imaging (GE-EPI) to draining vein signals by including the venous plexus in the analysis, we observed BOLD responses with fair reliability across days. Taken together, these results demonstrate that heat pain stimuli as short as one second are able to evoke a robust and spatially specific BOLD response, which is however strongly variable within participants across time, resulting in low reliability in the dorsal horn gray matter. Further improvements in data acquisition and analysis techniques are thus necessary before event-related spinal cord fMRI as used here can be reliably employed in longitudinal designs or clinical settings.

neuroscience↗

Neuroinfectiology of an atypical anthrax-causing pathogen in wild chimpanzees

Bacillus cereus biovar anthracis (Bcbva) is an atypical anthrax-causing bacterium, inflicting wildlife fatalities across African rainforest ecosystems. The pathogens virulence in one of our closest living relatives, the chimpanzee, together with human serological evidence, suggests Bcbva is zoonotic. While classical B. anthracis-induced anthrax has been described to affect the central nervous system at a progressive disease-state, the neuroinfectiology of Bcbva is yet unknown. Here we characterised the pathogens neuro-invasiveness via gross pathological assessment, ultra-high resolution quantitative Magnetic Resonance Imaging and histological analysis on four brains, which were extracted from naturally deceased wild chimpanzees in Tai National Park, Cote dIvoire. Based on macroscopically evident pial vessel congestion and haemorrhages as well as cortical siderosis detected via MRI, we concluded that Bcbva induced meningitis analogous to B. anthracis. Further, histological visualisation of bacteria and leukocytes in the subarachnoid space evidenced the bacteriums capability to breach the arachnoid barrier. Bcbva was detected in the brain parenchyma of all four cases. This indicates a higher ability to transgress the glia limitans and therefore exhibits a higher neuroinvasiveness compared to B. anthracis that predominantly stays confined to the meninges. Heightened glial fibrillary acidic protein (GFAP) expression but little morphological gliosis suggest a rapid disease progression leading to host-death within hours to a few days after central nervous system invasion. Overall our results reveal Bcbvas ability to breach blood-brain barriers which results in a pronounced neuropathogenicity. Bcbva causes extensive damage to the meninges and the brain parenchyma, as well as rapid and massive digestion of brain extracellular matrix in chimpanzees and potentially so in humans in case of zoonotic spillover.

neuroscience↗

Dynamic layer-specific processing in the prefrontal cortex during working memory

The dorsolateral prefrontal cortex (dlPFC) is reliably engaged in working memory (WM). Evidence from non-human primates indicates that the dlPFC comprises different cytoarchitectonic layers that play distinct roles in WM subprocesses; yet the functional role of the dlPFCs laminar circuitry in human WM is not well understood. In this study, participants completed a delayed-match-to-sample WM task while undergoing functional magnetic resonance imaging (fMRI) at ultra-high resolution, which allowed us to examine layer-specific responses of the dlPFC to manipulations in WM load and motor response. We conducted univariate and multivariate analyses across all periods of the WM task: encoding, delay and retrieval. First, we observed that superficial layers activate stronger than deep layers to higher WM load during the delay period. This aligns with earlier work showing preferential superficial layer activation to WM manipulation and as such may indicate lamina-specific activation of the frontoparietal network to heightened task demands more generally. Second, we found that superficial layers show higher decoding of WM load differences than deep layers during the retrieval period. In this context, we could show that decoding of WM load in the superficial layer exhibited dynamic changes across the encoding, delay and retrieval period of the task, indicative of separate WM control processes that occur on the WM content. Last, we found that superficial and deep layers are both non-differentially involved in the motor response, contradicting earlier findings of a preferential deep layer activation in humans. Taken together, our results provide new insights into the functional laminar circuitry of the dlPFC during WM and provide further support for a dynamic account of dlPFC coding.

neuroscience↗

Decoding of columnar-level organization across cortical depth using BOLD- and CBV-fMRI at 7 T

Multivariate pattern analysis (MVPA) methods are a versatile tool to retrieve information from neurophysiological data obtained with functional magnetic resonance imaging (fMRI) techniques. Since fMRI is based on measuring the hemodynamic response following neural activation, the spatial specificity of the fMRI signal is inherently limited by contributions of macrovascular compartments that drain the signal from the actual location of neural activation, making it challenging to image cortical structures at the spatial scale of cortical columns and layers. By relying on information from multiple voxels, MVPA has shown promising results in retrieving information encoded in fine-grained spatial patterns. We examined the spatial specificity of the signal exploited by MVPA. Over multiple sessions, we measured ocular dominance columns (ODCs) in human primary visual cortex (V1) with different acquisition techniques at 7 T. For measurements with blood oxygenation level dependent (BOLD) contrast, we included both gradient echo- (GE-BOLD) and spin echo-based (SE-BOLD) sequences. Furthermore, we acquired data using the vascular-space-occupancy (VASO) fMRI technique, which is sensitive to cerebral blood volume (CBV) changes. We used the data to decode eye-of-origin from signals across cortical layers. While ocularity information can be decoded with all imaging techniques, laminar profiles reveal that macrovascular contributions affect all acquisition methods, limiting their specificity across cortical depth. Therefore, although MVPA is a promising approach for investigating the mesoscopic circuitry of the human cerebral cortex, careful consideration of macrovascular contributions is needed that render the spatial specificity of the extracted signal.

neuroscience↗

Reliability of resting-state functional connectivity in the human spinal cord: assessing the impact of distinct noise sources

The investigation of spontaneous fluctuations of the blood-oxygen-level-dependent (BOLD) signal has recently been extended from the brain to the spinal cord, where it has stimulated interest from a clinical perspective. A number of resting-state functional magnetic resonance imaging (fMRI) studies have demonstrated robust functional connectivity between the time series of BOLD fluctuations in bilateral dorsal horns and between those in bilateral ventral horns, in line with the functional neuroanatomy of the spinal cord. A necessary step prior to extension to clinical studies is assessing the reliability of such resting-state signals, which we aimed to do here in a group of 45 healthy young adults at the clinically prevalent field strength of 3T. When investigating connectivity in the entire cervical spinal cord, we observed fair to good reliability for dorsal-dorsal and ventral-ventral connectivity, whereas reliability was poor for within- and between-hemicord dorsal-ventral connectivity. Considering how prone spinal cord fMRI is to noise, we extensively investigated the impact of distinct noise sources and made two crucial observations: removal of physiological noise led to a reduction in functional connectivity strength and reliability - due to the removal of stable and participant-specific noise patterns - whereas removal of thermal noise considerably increased the detectability of functional connectivity without a clear influence on reliability. Finally, we also assessed connectivity within spinal cord segments and observed that while the pattern of connectivity was similar to that of whole cervical cord, reliability at the level of single segments was consistently poor. Taken together, our results demonstrate the presence of reliable resting-state functional connectivity in the human spinal cord even after thoroughly accounting for physiological and thermal noise, but at the same time urge caution if focal changes in connectivity (e.g. due to segmental lesions) are to be studied, especially in a longitudinal manner.

neuroscience↗

B1+-correction of MT saturation maps optimized for 7T postmortem MRI of the brain

PurposeMagnetization transfer saturation (MTsat) is a useful marker to probe tissue macromolecular content and myelination in the brain. The increased [Formula] -inhomogeneity at [≥] 7T and significantly larger saturation pulse flip angles which are often used for postmortem studies exceed the limits where previous MTsat [Formula] correction methods are applicable. Here, we develop a calibration-based correction model and procedure, and validate and evaluate it in postmortem 7T data of whole chimpanzee brains. TheoryThe [Formula] dependence of MTsat was investigated by varying the off-resonance saturation pulse flip angle. For the range of saturation pulse flip angles applied in typical experiments on postmortem tissue, the dependence was close to linear. A linear model with a single calibration constant C is proposed to correct bias in MTsat by mapping it to the reference value of the saturation pulse flip angle. MethodsC was estimated voxel-wise in five postmortem chimpanzee brains. "Individual-based global parameters" were obtained by calculating the mean C within individual specimen brains and "group-based global parameters" by calculating the means of the individual-based global parameters across the five brains. ResultsThe linear calibration model described the data well, though C was not entirely independent of the underlying tissue and [Formula]. Individual-based and group-based global correction parameters (C = 1.2) led to visible, quantifiable reductions of [Formula]-biases in high resolution MTsat maps. ConclusionThe presented model and calibration approach effectively corrects for [Formula] in-homogeneities in postmortem 7T data.

neuroscience↗

High resolution quantitative and functional MRI indicate lower myelination of thin and thick stripes in human secondary visual cortex

The characterization of cortical myelination is essential for the study of structure-function relationships in the human brain. However, knowledge about cortical myelination is largely based on post mortem histology, which generally renders direct comparison to function impossible. The repeating pattern of pale-thin-pale-thick stripes of cytochrome oxidase (CO) activity in the primate secondary visual cortex (V2) is a prominent columnar system, in which histology also indicates different myelination of thin/thick versus pale stripes. We used quantitative magnetic resonance imaging (qMRI) in conjunction with functional magnetic resonance imaging (fMRI) at ultra-high field strength (7 T) to localize and study myelination of stripes in four human participants at sub-millimeter resolution in vivo. Thin and thick stripes were functionally localized by exploiting their sensitivity to color and binocular disparity, respectively. Resulting functional activation maps showed robust stripe patterns in V2 which enabled further comparison of quantitative relaxation parameters between stripe types. Thereby, we found lower longitudinal relaxation rates (R1) of thin and thick stripes compared to surrounding gray matter in the order of 1-2%, indicating higher myelination of pale stripes. No consistent differences were found for effective transverse relaxation rates [Formula]. The study demonstrates the feasibility to investigate structure-function relationships in living humans within one cortical area at the level of columnar systems using qMRI.

neuroscience↗

Quantitative MRI maps of human neocortex explored using cell type-specific gene expression analysis

Quantitative MRI (qMRI) allows extraction of reproducible and robust parameter maps. However, the connection to underlying biological substrates remains murky, especially in the complex, densely packed cortex. We investigated associations in human neocortex between qMRI parameters and neocortical cell types by comparing the spatial distribution of the qMRI parameters longitudinal relaxation rate (R1), effective transverse relaxation rate (R2*), and magnetization transfer saturation (MTsat) to gene expression from the Allen Human Brain Atlas, then combining this with lists of genes enriched in specific cell types found in the human brain. As qMRI parameters are magnetic field strength-dependent, the analysis was performed on MRI data at 3T and 7T. All qMRI parameters significantly covaried with genes enriched in GABA- and glutamatergic neurons, i.e. they were associated with cytoarchitecture. The qMRI parameters also significantly covaried with the distribution of genes enriched in astrocytes (R2* at 3T, R1 at 7T), endothelial cells (R1 and MTsat at 3T), microglia (R1 and MTsat at 3T, R1 at 7T), and oligodendrocytes (R1 at 7T). These results advance the potential use of qMRI parameters as biomarkers for specific cell types.

neuroscience↗

Deciphering the fibre-orientation independent component of R2* (R2,iso*) in the human brain with a single multi-echo gradient-recalled-echo measurement under varying microstructural conditions

The effective transverse relaxation rate (R2*) is sensitive to the microstructure of the human brain, e.g. the g-ratio characterising the relative myelination of axons. However, R2* depends on the orientation of the fibres relative to the main magnetic field degrading its reproducibility and that of any microstructural derivative measure. To decipher its orientation-independent part (R2,iso*), a second-order polynomial in time (M2) can be applied to single multi-echo gradient-recalled-echo (meGRE) measurements at arbitrary orientation. The linear-time dependent parameter, {beta}1, of M2 can be biophysically related to R2,iso* when neglecting the signal from the myelin water (MW) in the hollow cylinder fibre model (HCFM). Here, we examined the effectiveness of M2 using experimental and simulated data with variable g-ratio and fibre dispersion. We showed that the fitted {beta}1 effectively estimates R2,iso*when using meGRE with long maximum echo time (TEmax {approx} 54 ms) but its microscopic dependence on the g-ratio was not accurately captured. This error was reduced to less than 12% when accounting for the MW contribution in a newly introduced biophysical expression for {beta}1. We further used this new expression to estimate the MW fraction (0.14) and g-ratio (0.79) in a human optic chiasm. However, the proposed method failed to estimate R2,iso* for a typical in-vivo meGRE protocol (TEmax {approx} 18 ms). At this TEmax and around the magic angle, the HCFM-based simulations failed to explain the R2*-orientation-dependence. In conclusion, estimation of R2,iso* with M2 in vivo requires meGRE protocols with very long TEmax {approx} 54 ms.

neuroscience↗

Assessing Quantitative MRI Techniques using Multimodal Comparisons

The study of brain structure and change in neuroscience is commonly conducted using macroscopic morphological measures of the brain such as regional volume or cortical thickness, providing little insight into the microstructure and physiology of the brain. In contrast, quantitative MRI allows the monitoring of microscopic brain change non-invasively in-vivo, and provides normative values for comparisons between tissues, regions, and individuals. To support the development and common use of qMRI for cognitive neuroscience, we analysed a set of qMRI metrics (R1, R2*, Magnetization Transfer saturation, Proton Density saturation, Fractional Anisotropy, Mean Diffusivity) in 101 healthy young adults. Here we provide a comprehensive descriptive analysis of these metrics and their linear relationships to each other in grey and white matter to develop a more complete understanding of the relationship to tissue microstructure. Furthermore, we provide evidence that combinations of metrics may uncover informative gradients across the brain by showing that lower variance components of PCA may be used to identify cortical gradients otherwise hidden within individual metrics. We discuss these results within the context of microstructural and physiological neuroscience research.

neuroscience↗

Error quantification in multi-parameter mapping facilitates robust estimation and enhanced group level sensitivity

Multi-Parameter Mapping (MPM) is a comprehensive quantitative neuroimaging protocol that enables estimation of four physical parameters (longitudinal and effective transverse relaxation rates R1 and [Formula], proton density PD, and magnetization transfer saturation MTsat) that are sensitive to microstructural tissue properties such as iron and myelin content. Their capability to reveal microstructural brain differences, however, is tightly bound to controlling random noise and artefacts (e.g. caused by head motion) in the signal. Here, we introduced a method to estimate the local error of PD, R1 and MTsat maps that captures both noise and artefacts on a routine basis without requiring additional data. To investigate the methods sensitivity to random noise, we calculated the model-based signal-to-noise ratio (mSNR) and showed in measurements and simulations that it correlated linearly with an experimental raw-image-based SNR map. We found that the mSNR varied with MPM protocols, magnetic field strength (3T vs. 7T) and MPM parameters: it halved from PD to R1 and decreased from PD to MTsat by a factor of 3-4. Exploring the artefact-sensitivity of the error maps, we generated robust MPM parameters using two successive acquisitions of each contrast and the acquisition-specific errors to down-weight erroneous regions. The resulting robust MPM parameters showed reduced variability at the group level as compared to their single-repeat or averaged counterparts. The error and mSNR maps may better inform power-calculations by accounting for local data quality variations across measurements. Code to compute the mSNR maps and robustly combined MPM maps is available in the open-source hMRI toolbox.

neuroscience↗

Benchmarking GE-BOLD, SE-BOLD, and SS-SI-VASO sequences for depth-dependent separation of feedforward and feedback signals in high-field MRI

Recent advances in high-field fMRI have allowed differentiating feedforward and feedback information in the grey matter of the human brain. For continued progress in this endeavor, it is critical to understand how MRI data acquisition parameters impact the read-out of information from laminar response profiles. Here, we benchmarked three different MR-sequences at 7T - gradient-echo (GE), spin-echo (SE) and vascular space occupancy imaging (VASO) - in differentiating feedforward and feedback signals in human early visual cortex (V1). The experiment (N=4) consisted of two complementary tasks: a perception task that predominantly evokes feedforward signals and a working memory task that relies on feedback signals. In the perception task, participants saw flickering oriented gratings while detecting orthogonal color-changes. In the working memory task, participants memorized the precise orientation of a grating. We used multivariate pattern analysis to read out the perceived (feedforward) and memorized (feedback) grating orientation from neural signals across cortical depth. Analyses across all the MR-sequences revealed perception signals predominantly in the middle cortical compartment of area V1 and working memory signals in the deep compartment. Despite an overall consistency across sequences, SE-EPI was the only sequence where both feedforward and feedback information were differently pronounced across cortical depth in a statistically robust way. We therefore suggest that in the context of a typical cognitive neuroscience experiment as the one benchmarked here, SE-EPI may provide a favorable trade-off between spatial specificity and signal sensitivity. HighlightsHere, we benchmarked three sequences at high-field fMRI -GE-BOLD, SE-BOLD and VASO - in differentiating feedforward and feedback signals across grey matter depth of area V1. We show that: O_LIAll the MR-sequences revealed the feedforward and feedback signals at the middle and deep cortical bins, respectively. C_LIO_LISuch correspondence across the sequences indicates that widely used GE-BOLD is a suitable method for the exploration of signals in cortical depth. C_LIO_LIOnly SE-BOLD yielded statistically reliable differences between the cortical bins carry- ing feedforward and feedback signals. C_LI

neuroscience↗

Reliability of quantitative multiparameter maps is high for MT and PD but attenuated for R1 and R2* in healthy young adults

We investigate the reliability of individual differences of four quantities measured by magnetic resonance imaging based multiparameter mapping (MPM): magnetization transfer (MT), proton density (PD), longitudinal relaxation rate (R1), and effective transverse relaxation rate (R2*). A total of four MPM datasets, two on each of two consecutive days, were acquired in healthy young adults. On Day 1, no repositioning occurred; on Day 2, participants were repositioned between MPM datasets. Using intra-class correlation effect decomposition (ICED), we assessed the contributions of session-specific, day-specific, and residual sources of measurement error. For whole-brain gray and white matter, all four MPM parameters showed high reproducibility and high reliability, as indexed by the coefficient of variation (CoV) and the intra-class correlation (ICC). However, MT, PD, R1, and R2* differed markedly in the extent to which reliability varied across brain regions. MT and PD showed high reliability in almost all regions. In contrast, R1 and R2* showed low reliability in some regions outside the basal ganglia, such that the sum of the measurement error estimates in our structural equation model was higher than estimates of between-person differences. In sum, in this sample of healthy young adults, the four MPM parameters showed very little variability over four measurements over two days but differed in how well they could assess between-person differences. We conclude that R1 and R2* might carry only limited person-specific information in samples of healthy young adults, and, by implication, might be of restricted utility for studying associations to between-person differences in behavior.

neuroscience↗

Automated slice-specific z-shimming for fMRI of the human spinal cord

Functional magnetic resonance imaging (fMRI) of the human spinal cord faces many challenges, such as signal loss due to local magnetic field inhomogeneities. This issue can be addressed with slice-specific z-shimming, which compensates for the dephasing effect of the inhomogeneities using a slice-specific gradient pulse. Here, we aim to address outstanding issues regarding this technique by evaluating its effects on several aspects that are directly relevant for spinal fMRI and by developing two automated procedures in order to improve upon the time-consuming and subjective nature of manual selection of z-shims: one procedure finds the z-shim that maximizes signal intensity in each slice of an EPI reference-scan and the other finds the through-slice field inhomogeneity for each EPI-slice in field map data and calculates the required compensation gradient moment. We demonstrate that the beneficial effects of z-shimming are apparent across different echo times, hold true for both the dorsal and ventral horn, and are also apparent in the temporal signal-to-noise ratio (tSNR) of EPI time-series data. Both of our automated approaches were faster than the manual approach, lead to significant improvements in gray matter tSNR compared to no z-shimming and resulted in beneficial effects that were stable across time. While the field-map-based approach performed slightly worse than the manual approach, the EPI-based approach performed as well as the manual one and was furthermore validated on an external corticospinal data-set (N>100). Together, automated z-shimming may improve the data quality of future spinal fMRI studies and lead to increased reproducibility in longitudinal studies.

neuroscience↗

Reducing susceptibility distortion related image blurring in diffusion MRI EPI data

Diffusion magnetic resonance imaging (MRI) is an increasingly popular technique in basic and clinical neuroscience. One promising application is to combine diffusion MRI with myelin maps from complementary MRI techniques such as multi-parameter mapping (MPM) to produce g-ratio maps that represent the relative myelination of axons and predict their conduction velocity. Statistical Parametric Mapping (SPM) can process both diffusion data and MPMs, making SPM the only widely accessible software that contains all the processing steps required to perform group analyses of g-ratio data in a common space. However, limitations have been identified in its method for reducing susceptibility-related distortion in diffusion data. More generally, susceptibility-related image distortion is often corrected by combining reverse phase-encoded images (blip-up and blip-down) using the arithmetic mean (AM), however, this can lead to blurred images. In this study we sought to (1) improve the susceptibility-related distortion correction for diffusion MRI data in SPM; (2) deploy an alternative approach to the AM to reduce image blurring in diffusion MRI data when combining blip-up and blip-down EPI data after susceptibility-related distortion correction; and (3) assess the benefits of these changes for g-ratio mapping. We found that the new processing pipeline, called consecutive Hyperelastic Susceptibility Artefact Correction (HySCO) improved distortion correction when compared to the standard approach in the ACID toolbox for SPM. Moreover, using a weighted average (WA) method to combine the distortion corrected data from each phase-encoding polarity achieved greater overlap of diffusion and more anatomically faithful structural white matter probability maps derived from minimally distorted multi-parameter maps as compared to the AM. Third, we showed that the consecutive HySCO WA performed better than the AM method when combined with multi-parameter maps to perform g-ratio mapping. These improvements mean that researchers can conveniently access a wide range of diffusion-related analysis methods within one framework because they are now available within the open-source ACID toolbox as part of SPM, which can be easily combined with other SPM toolboxes, such as the hMRI toolbox, to facilitate computation of myelin biomarkers that are necessary for g-ratio mapping.

neuroscience↗