Search bioRxiv⌕ Search

Biology subjects

Walston, S. T.

Publications and source records attributed to Walston, S. T..

2 recordsLinked to original sources

Extraocular Electrical Stimulation Activates Retinal Ganglion Cells In Vivo

Objective: Here, we directly demonstrate that extraocular electrical stimulation can reliably activate retinal ganglion cells (RGCs) in vivo and systematically identify optimal stimulation waveforms that maximize RGC activation at tolerable amplitudes. Approach: Using transpupillary two-photon calcium imaging in Thy1-GCaMP6f rats, we directly visualized RGC activation during extraocular electrical stimulation with single-cell resolution. We tested symmetric (SCB 1:1) and asymmetric (ACB 1:4) charge-balanced waveforms across frequencies ranging from 20 to 5,000 Hz and amplitudes from 1 to 300 uA, correlating cellular calcium responses with behavioral outcomes during awake stimulation. Main Results: ACB 1:4 stimulation at lower frequencies (20-50 Hz) robustly and reliably activates RGC somas in vivo, producing larger calcium responses at lower amplitudes than SCB 1:1. At comparable amplitudes, ACB stimulation generated 1.8-fold greater calcium responses. In contrast, SCB stimulation required higher amplitudes that exceeded animal tolerance before reliable RGC activation could be achieved. Significance: These findings provide direct evidence that extraocular electrodes can reliably activate RGCs in vivo. Notably, stimulation parameters previously associated with full-length optic nerve regeneration were found to be minimally effective at activating RGCs in vivo, suggesting increased gains could be had with newer approaches. The results further demonstrate that waveform asymmetry improves the efficiency of optic nerve stimulation by engaging RGC somas at lower, more tolerable, amplitudes. By combining two-photon imaging with behavioral tolerance testing, this work defines a practical therapeutic window for extraocular stimulation of the eye and establishes asymmetric charge-balanced waveforms as a more clinically translatable strategy for visual pathway neuromodulation.

bioengineering↗

Graphene-based thin film microelectrode technology for in vivo high resolution neural recording and stimulation

Neuroprosthetic technology aims to restore nervous system functionality in cases of severe damage or degeneration by recording and stimulating the electrical activity of the neural tissue. One of the key factors determining the quality of the neuroprostheses is the electrode material used to establish electrical communication with the neural tissue, which is subject to strict electrical, electrochemical, and mechanical specifications as well as biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin film technology and its engineering to form flexible neural implants. Bench measurements show that the developed microelectrodes offer low impedance and high charge injection capacity throughout millions of pulses. In vivo electrode performance was assessed in rodents both from brain surface and intracortically showing high-fidelity recording performance, while stimulation performance was assessed with an intrafascicular implant that demonstrated low current thresholds and high selectivity for activating subsets of axons within the sciatic nerve. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical and intraneural implantation. Overall, this works describes a novel graphene-based thin film microelectrode technology and demonstrates its potential for high-precision neural interfacing in both recording and stimulation applications.

bioengineering↗