Search bioRxiv⌕ Search

Biology subjects

Voroslakos, M.

Publications and source records attributed to Voroslakos, M..

10 recordsLinked to original sources

Spatiotemporal Patterns Differentiate Hippocampal Sharp-Wave Ripples from Interictal Epileptiform Discharges in Mice and Humans

Hippocampal sharp-wave ripples (SPW-Rs) are high-frequency oscillations critical for memory consolidation in mammals. Despite extensive characterization in rodents, their application as biomarkers to track and treat memory dysfunction in humans is limited by coarse spatial sampling, interference from interictal epileptiform discharges (IEDs), and lack of consensus on human SPW-R localization and morphology. We demonstrate that mouse and human hippocampal ripples share spatial, spectral and temporal features, which are clearly distinct from IEDs. In 1024-channel hippocampal recordings from APP/PS1 mice, SPW-Rs were distinguishable from IEDs by their narrow localization to the CA1 pyramidal layer, narrowband frequency peaks, and multiple ripple cycles on the unfiltered local field potential. In epilepsy patients, ripples showed similar narrowband frequency peaks and visible ripple cycles in CA1 and the subiculum but were absent in the dentate gyrus. Conversely, IEDs showed a broad spatial extent and wide-band frequency power. We introduce a semi-automated, human ripple detection toolbox ("ripmap") selecting optimal detection channels and separating event waveforms by low-dimensional embedding. Our approach improves ripple detection accuracy, providing a firm foundation for future human memory research.

neuroscience↗

Repeated tDCS at clinically-relevant field intensity can boost concurrent motor learning in rats.

Electric fields used in clinical trials with transcranial direct current stimulation (tDCS) are small, with magnitudes that have yet to demonstrate measurable effects in preclinical animal models. We hypothesized that weak stimulation will nevertheless produce sizable effects, provided that it is applied concurrently with behavioral training, and repeated over multiple sessions. We tested this here in a rodent model of dexterous motor-skill learning. We developed a preparation that allows concurrent stimulation during the performance of a pellet-reaching task in freely behaving rats. The task was automated to minimize experimenter bias. We measured field magnitudes intracranially to calibrate the stimulation current. In this study, only male rats were used. Animals were trained for 20 min with concurrent epicranial tDCS over 10 daily sessions. Behavior was recorded with high-speed video to quantify reaching dynamics. We also measured motor-evoked potentials (MEPs) bilaterally with epidural microstimulation. The new electrode montage enabled stable stimulation over 10 sessions with a field intensity of 2V/m at the motor cortex. The number of successful reaches improved across days of training, and the rate of learning was higher in the anodal group as compared to sham-control animals (F(1)=7.12, p=0.008, N=24). MEPs were not systematically affected by tDCS. Posthoc analysis suggests that tDCS modulated motor learning only for right-pawed animals, improving success of reaching, but limiting stereotypy in these animals. Repeated and concurrent anodal tDCS can boost motor-skill learning at clinically-relevant field intensities. In this animal model the effect interacted with paw preference and was not associated with corticospinal excitability. Significance StatementThe effects of tDCS have been explored in numerous human clinical trials, but the mechanisms of action of weak electric fields remain unclear. In vitro studies show that constant electric fields at 2.5 V/m can enhance the efficacy of synapses undergoing plasticity. This study demonstrates in a rodent model that tDCS of only 2 Vm when applied concurrently to behavioral training can improve motor skill learning, and reduce stereotypy of reaching behavior. These effects accumulated over 10 days of training. Motor evoked potentials (MEP), which are often used to demonstrate plastic effects in humans on a time scale of hours, were not measurably affected by tDCS on this longer time scale.

animal behavior and cognition↗

Topography of putative bidirectional interaction between hippocampal sharp wave ripples and neocortical slow oscillations

Systems consolidation relies on coordination between hippocampal sharp-wave ripples (SWRs) and neocortical UP/DOWN states during sleep. However, whether this coupling exists across neocortex and the mechanisms enabling it remain unknown. By combining electrophysiology in mouse hippocampus (HPC) and retrosplenial cortex (RSC) with widefield imaging of dorsal neocortex, we found spatially and temporally precise bidirectional hippocampo-neocortical interaction. HPC multi-unit activity and SWR probability was correlated with UP/DOWN states in mouse default mode network, with highest modulation by RSC in deep sleep. Further, some SWRs were preceded by the high rebound excitation accompanying DMN DOWN[->]UP transitions, while large-amplitude SWRs were often followed by DOWN states originating in RSC. We explain these electrophysiological results with a model in which HPC and RSC are weakly coupled excitable systems capable of bi-directional perturbation and suggest RSC may act as a gateway through which SWRs can perturb downstream cortical regions via cortico-cortical propagation of DOWN states.

neuroscience↗

Dual-color micro-LEDs integrated neural interface for multi-control optogenetic electrophysiology

Over recent decades, optogenetics has become a pivotal technique for elucidating the functionality of neuronal circuits in living organisms. By genetically modifying specific cells within targeted tissues to respond to particular optical stimuli, researchers can achieve precise activation or inhibition of these cells. This capability enables detailed investigations of neural circuitry with unprecedented accuracy. However, there is a rising need for hardware that supports bidirectional control in conjunction with electrophysiological recording. A significant challenge in this domain is the compact integration of dual light sources and a recording system. This study addresses this challenge through the development of a novel microfabrication and assembly technique for embedding dual-color micro-LEDs and recording electrodes into a Michigan-type neural probe structure, designated as DuoLite (Dual-color micro-LEDs Integrated Neural-Interface Optoelectrode for Multi-Control Optogenetic Electrophysiology). We present two device variants: (a) a small-group and (b) a large-group cell-targeted design, each incorporating micro-LEDs with a minimal area of <100 m2 for both red and blue light. The design and assembly techniques for integrating all three components within a shank width of <100 m are thoroughly detailed, and the functionality of the devices is validated through in vivo experiments.

bioengineering↗

Self-Assembled Origami Neural Probes for Scalable, Multifunctional, Three-Dimensional Neural Interface

Flexible intracortical neural probes have drawn attention for their enhanced longevity in high-resolution neural recordings due to reduced tissue reaction. However, the conventional monolithic fabrication approach has met significant challenges in: (i) scaling the number of recording sites for electrophysiology; (ii) integrating of other physiological sensing and modulation; and (iii) configuring into three-dimensional (3D) shapes for multi-sided electrode arrays. We report an innovative self-assembly technology that allows for implementing flexible origami neural probes as an effective alternative to overcome these challenges. By using magnetic-field-assisted hybrid self-assembly, multiple probes with various modalities can be stacked on top of each other with precise alignment. Using this approach, we demonstrated a multifunctional device with scalable high-density recording sites, dopamine sensors and a temperature sensor integrated on a single flexible probe. Simultaneous large-scale, high-spatial-resolution electrophysiology was demonstrated along with local temperature sensing and dopamine concentration monitoring. A high-density 3D origami probe was assembled by wrapping planar probes around a thin fiber in a diameter of 80[~]105 m using optimal foldable design and capillary force. Directional optogenetic modulation could be achieved with illumination from the neuron-sized micro-LEDs (LEDs) integrated on the surface of 3D origami probes. We could identify angular heterogeneous single-unit signals and neural connectivity 360{degrees} surrounding the probe. The probe longevity was validated by chronic recordings of 64-channel stacked probes in behaving mice for up to 140 days. With the modular, customizable assembly technologies presented, we demonstrated a novel and highly flexible solution to accommodate multifunctional integration, channel scaling, and 3D array configuration.

neuroscience↗

Transcranial electric stimulation modulates firing rate at clinically relevant intensities

Notwithstanding advances with low-intensity transcranial electrical stimulation (TES), there remain questions about the efficacy of clinically realistic electric fields on neuronal function. We used Neuropixels 2.0 probe with 384 channels in an in-vivo rat model of TES to detect effects of weak fields on neuronal firing rate. High-density field mapping and computational models verified field intensity (1 V/m in hippocampus per 50 {micro}A of applied skull currents). We demonstrate that electric fields below 0.5 V/m acutely modulate firing rate in 5% of neurons recorded in the hippocampus. At these intensities, average firing rate effects increased monotonically with electric field intensity at a rate of 7 % per V/m. For the majority of excitatory neurons, firing increased for cathodal stimulation and diminished for anodal stimulation. While more diverse, the response of inhibitory neurons followed a similar pattern on average, likely as a result of excitatory drive. Our results indicate that responses to TES at clinically relevant intensities are driven by a fraction of high-responder excitatory neurons, with polarity-specific effects. We conclude that transcranial electric stimulation is an effective neuromodulator at clinically realistic intensities.

neuroscience↗

ThermoMaze: A behavioral paradigm for readout of immobility-related brain events

Brain states fluctuate between exploratory and consummatory phases of behavior. These state changes affect both internal computation and the organisms responses to sensory inputs. Understanding neuronal mechanisms supporting exploratory and consummatory states and their switching requires experimental control of behavioral shifts and collecting sufficient amounts of brain data. To achieve this goal, we developed the ThermoMaze, which exploits the animals natural warmth-seeking homeostatic behavior. By decreasing the floor temperature and selectively heating unmarked areas, mice avoid the aversive state by exploring the maze and finding the warm spot. In its design, the ThermoMaze is analogous to the widely used water maze but without the inconvenience of a wet environment and, therefore, allows the collection of physiological data in many trials. We combined the ThermoMaze with electrophysiology recording, and report that spiking activity of hippocampal CA1 neurons during sharp-wave ripple events encode the position of the animal. Thus, place-specific firing is not confined to locomotion and associated theta oscillations but persist during waking immobility and sleep at the same location. The ThermoMaze will allow for detailed studies of brain correlates of immobility, preparatory-consummatory transitions and open new options for studying behavior-mediated temperature homeostasis.

neuroscience↗

Simultaneous Electrophysiology and Optogenetic Perturbation of the Same Neurons in Chronically Implanted Animals using microLED Silicon Probes

Optogenetics are a powerful tool for testing how a neural circuit influences neural activity, cognition, and behavior. Accordingly, the number of studies employing optogenetic perturbation has grown exponentially over the last decade. However, recent studies have highlighted that the impact of optogenetic stimulation/silencing can vary depending on the construct used, the local microcircuit connectivity, extent/power of illumination, and neuron types perturbed. Despite these caveats, the majority of studies employ optogenetics without simultaneously recording neural activity in the circuit that is being perturbed. This dearth of simultaneously recorded neural data is due in part to technical difficulties in combining optogenetics and extracellular electrophysiology. The recent introduction of LED silicon probes, which feature independently controllable miniature LEDs embedded at several levels of each of multiple shanks of silicon probes, provides a tractable method for temporally and spatially precise interrogation of neural circuits. Here, we provide a protocol addressing how to perform chronic recordings using LED probes. This protocol provides a schematic for performing causal and reproducible interrogations of neural circuits and addresses all phases of the recording process: introduction of optogenetic construct, implantation of the LED probe, performing simultaneous optogenetics and electrophysiology in vivo, and post-processing of recorded data. SUMMARYThis method allows a researcher to simultaneously perturb neural activity and record electrophysiological signal from the same neurons with high spatial specificity using silicon probes with integrated LEDs. We outline a procedure detailing all stages of the process for performing reliable LED experiments in chronically implanted rodents.

neuroscience↗

flexLiTE: flexible micro-LED integrated optoelectrodesfor minimally-invasive chronic deep-brain study

Understanding complex neuronal circuitry and its functions of a living organism requires a specialized tool which is capable of recording a large ensemble of neuronal signals at single cell resolution and modulating neuronal activities selectively in the target region of brains with high spatiotemporal resolution, while sustaining long-term chronic operation without significant tissue degeneration or device shifts. We hereby present an ultra-flexible, minimally-invasive, Michigan-type neural probe for chronic opto-electrophysiology studies: flexLiTE (flexible micro-LED integrated optoelectrodes). flexLiTE incorporates monolithically integrated, soma-sized inorganic micro-LEDs (12 individually operated) and 32 recording electrodes. Both stimulation and recording modalities were achieved by stacking two modules on a flexible substrate: one with micro-LEDs for neuromodulation and the other with recording sites, resulting in a 115 m-wide,12 m-thick, 10 mm-long optoelectrode. From prototype devices, we demonstrated the reliable operation of flexLiTEs for recording and modulation of hippocampal neurons in a freely moving mice for over [~]8 month.

bioengineering↗

Brain-implanted conductors amplify radiofrequency fields in rodents: advantages and risks

Over the past few decades, daily exposure to radiofrequency (RF) fields has been increasing due to the rapid development of wireless and medical imaging technologies. Under extreme circumstances, exposure to very strong RF energy can lead to heating of body tissue, even resulting in tissue injury. The presence of implanted devices, moreover, can amplify RF effects on surrounding tissue. Therefore, it is important to understand the interactions of RF fields with tissue in the presence of implants, in order to establish appropriate wireless safety protocols, and also to extend the benefits of medical imaging to increasing numbers of people with implanted medical devices. This study explored the neurological effects of RF exposure in rodents implanted with neuronal recording electrodes. We exposed freely moving and anesthetized rats and mice to 950 MHz RF energy while monitoring their brain activity, temperature, and behavior. We found that RF exposure could induce fast onset firing of single neurons without heat injury. In addition, brain implants enhanced the effect of RF stimulation resulting in reversible behavioral changes. Using an optical temperature measurement system, we found greater than tenfold increase in brain temperature in the vicinity of the implant. On the one hand, our results underline the importance of careful safety assessment for brain implanted devices, but on the other hand, we also show that metal implants may be used for neurostimulation if brain temperature can be kept within safe limits.

neuroscience↗