Search bioRxiv⌕ Search

Biology subjects

Vanwanseele, B.

Publications and source records attributed to Vanwanseele, B..

6 recordsLinked to original sources

Detecting Sleep Deprivation from Running Biomechanics Using Machine Learning Classification: A Comparison Between Wearable and Laboratory Motion Capture

Sleep deprivation is associated with impaired endurance performance and an increased risk of running-related injury. Previous research has identified alterations in running biomechanics following a single night of sleep deprivation under laboratory conditions. However, whether these biomechanical changes can be detected using wearable technology remains unknown. Twenty-one recreationally active runners completed submaximal treadmill running under both normal sleep and total sleep deprivation conditions in a randomized crossover design. Biomechanical features were extracted simultaneously using a full-body motion capture system and a trunk-mounted wearable sensor. Five machine learning classifiers were evaluated in two classification tasks: a within-subject task using paired recordings from the same individual, and a between-subject task performed without individual baseline data. Within-subject classification consistently exceeded chance level for both measurement systems, with best accuracies of 85% for the wearable sensor (Logistic Regression) and 83% for the motion capture system (Random Forest). These findings indicate that sleep deprivation produces a systematic and individually consistent biomechanical signature during running. In contrast, between-subject classification failed across nearly all models and systems, with accuracies remaining close to chance level ([~]50%), demonstrating that inter-individual variability obscures the sleep-deprivation signal in the absence of personalized baseline data. Both systems converged on temporal organization, loading-related variables, and stride-to-stride variability as the most discriminative feature domains. Contrary to expectations, the laboratory motion capture system did not outperform the wearable sensor. Together, these findings demonstrate that individualized, baseline-referenced monitoring is essential for detecting sleep-deprivation-related changes in running gait, and suggest that a single trunk-mounted wearable sensor may provide a practical solution for real-world monitoring when paired recordings are available.

bioengineering↗

Estimation of the Achilles tendon twist in vivo by individual triceps surae muscle stimulation

The Achilles tendon (AT) is comprised of three distinct subtendons, each arising from the one of the three heads of the triceps surae muscles: gastrocnemius medialis (GM), gastrocnemius lateralis (GL) and soleus (SOL). These subtendons exhibit a twisted structure, classified as low (Type I), medium (Type II), and high (Type III) twist, based on cadaveric studies. Nevertheless, the in-vivo investigation of AT twist is notably scarce, resulting in a limited understanding of its functional significance. The aim of this study was to give insights into the complex 3D AT structure in vivo. 30 healthy participants underwent individual stimulation of each of the triceps surae muscles at rest with the foot attached to the pedal of an isokinetic dynamometer. Ultrasound images were captured to concomitantly examine the displacement of the superficial, middle and deep AT layers. SOL stimulation resulted in the highest AT displacement followed by GM and GL stimulation. Independent of the muscle stimulated, non-uniformity within the AT was observed with the deep layer exhibiting more displacement compared to the middle and superficial layers, hence important inter-individual differences in AT displacement were noticeable. By leveraging these individual displacement patterns during targeted stimulations in conjunction with cadaveric twist classifications providing insights into the area of each specific subtendon, our classification identified 19 subjects with a low and 11 subjects with a high AT twist. More research is needed to understand the complexity of the AT twisted structure in vivo to further understand its effect on AT properties and behaviour.

physiology↗

Reduced intra-tendinous sliding in Achilles tendinopathy during active plantarflexion regardless of horizontal foot position

The Achilles tendon consists of three subtendons with the ability to slide relative to each other. As optimal intra-tendinous sliding is thought to reduce the overall stress in the tendon, alterations in sliding behavior could potentially play a role in the development of Achilles tendinopathy. The aims of this study were to investigate the difference in intra-tendinous sliding within the Achilles tendon during isometric contractions between asymptomatic controls and patients with Achilles tendinopathy and the effect of changing the horizontal foot position on intra-tendinous sliding in both groups. 29 participants (13 Achilles tendinopathy, 16 controls) performed isometric plantarflexion contractions at 60% of their maximal voluntary contraction (MVC), in toes-neutral, and at 30% MVC in toes-neutral, toes-in and toes-out positions during which ultrasound images were recorded. Intra-tendinous sliding was estimated as the superficial-to-middle and middle-to-deep relative displacement. Our results indicate that patients with Achilles tendinopathy present lower intra-tendinous sliding compared to asymptomatic controls. Regarding the horizontal foot position in both groups, the toes-out foot position resulted in increased sliding compared to both toes-neutral and toes-out foot position. We provided evidence that patients with Achilles tendinopathy show lower intra-tendinous sliding compared to asymptomatic controls. Since intra-tendinous sliding is a physiological feature of the Achilles tendon, the external foot position holds promise to increase sliding in patients with Achilles tendinopathy and promote healthy tendon behavior. Future research should investigate if implementing this external foot position in rehabilitation programs stimulates sliding within the Achilles tendon and improves clinical outcome.

pathology↗

Achilles tendon stiffness minimizes the energy cost in simulations of walking in older but not in young adults

Both Achilles tendon stiffness and walking patterns influence the energy cost of walking, but their relative contributions remain unclear. These independent contributions can only be investigated using simulations. We created models for 16 young (24{+/-}2 years) and 15 older (75{+/-}4 years) subjects, with individualized (using optimal parameter estimations) and generic triceps surae muscle-tendon parameters. We varied Achilles tendon stiffness and calculated the energy cost of walking. Both in young and older adults, Achilles tendon stiffness independently contributed to the energy cost of walking. However, overall, a 25% increase in Achilles tendon stiffness increased the triceps surae and whole-body energy cost of walking with approximately 7% and 1.5%, respectively. Therefore, the influence of Achilles tendon stiffness is rather limited. Walking patterns also independently contributed to the energy cost of walking because the plantarflexor (including, but not limited to the triceps surae) energy cost of walking was lower in older than in young adults. Hence, training interventions should probably rather target specific walking patterns than Achilles tendon stiffness to decrease the energy cost of walking. However, based on the results of previous experimental studies, we expected that the calculated hip extensor and whole-body energy cost of walking would be higher in older than in young adults. This was not confirmed in our results. Future research might therefore assess the contribution of the walking pattern to the energy cost of walking by individualizing maximal isometric muscle force and by using three-dimensional models of muscle contraction. Summary statementAchilles tendon stiffness and walking patterns independently contribute to the energy cost in simulations of walking in young and older adults. The influence of Achilles tendon stiffness is rather small.

physiology↗

Habitual foot strike pattern does not affect simulated Triceps Surae muscle metabolic energy consumption during running

Foot strike pattern affects ankle joint work and Triceps Surae muscle-tendon dynamics during running. Whether these changes in muscle-tendon dynamics also affect Triceps Surae muscle energy consumption is still unknown. In addition, as the Triceps Surae muscle accounts for a substantial amount of the whole body metabolic energy consumption, changes in Triceps Surae energy consumption may affect whole body metabolic energy consumption. However, direct measurements of muscle metabolic energy consumption during dynamic movements is hard. Model-based approaches can be used to estimate individual muscle and whole body metabolic energy consumption based on Hill type muscle models. In this study, we use an integrated experimental and dynamic optimization approach to compute muscle states (muscle forces, lengths, velocities, excitations and activations) of 10 habitual mid-/forefoot striking and 9 habitual rearfoot striking runners while running at 10 and 14 km/h. The Achilles tendon stiffness of the musculoskeletal model was adapted to fit experimental ultrasound data of the Gastrocnemius medialis muscle during ground contact. Next, we calculated Triceps Surae muscle and whole body metabolic energy consumption using four different metabolic energy models provided in literature. Neither Triceps Surae metabolic energy consumption (p > 0.35), nor whole body metabolic energy consumption (p > 0.14) was different between foot strike patterns, regardless of the energy model used or running speed tested. Our results provide new evidence that mid-/forefoot and rearfoot strike pattern are metabolically equivalent.

physiology↗

Ultrasound-based optimal parameter estimation improves assessment of calf muscle-tendon interaction during walking

We present and evaluate a new approach to estimate calf muscle-tendon parameters and calculate calf muscle-tendon function during walking. We used motion analysis, ultrasound, and EMG data of the calf muscles collected in six young and six older adults during treadmill walking as inputs to a new optimal estimation algorithm. We used estimated parameters or scaled generic parameters in an existing approach to calculate muscle fiber lengths and activations. We calculated the fit with experimental data in terms of root mean squared differences (RMSD) and coefficients of determination (R2). We also calculated the calf muscle metabolic energy cost. RMSD between measured and calculated fiber lengths and activations decreased and R2 increased when estimating parameters compared to using scaled generic parameters. Moreover, R2 between measured and calculated gastrocnemius medialis fiber length and soleus activations increased by 19 % and 70 %, and calf muscle metabolic energy decreased by 25% when using estimated parameters compared to using scaled generic parameters at speeds not used for estimation. This new approach estimates calf muscle-tendon parameters in good accordance with values reported in literature. The approach improves calculations of calf muscle-tendon interaction during walking and highlights the importance of individualizing calf muscle-tendon parameters.

bioengineering↗