Search bioRxiv⌕ Search

Biology subjects

Vajda, E.

Publications and source records attributed to Vajda, E..

2 recordsLinked to original sources

Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System

Magnetoencephalography (MEG) non-invasively provides important information about human brain electrophysiology. The growing use of optically pumped magnetometers (OPM) for MEG, as opposed to fixed arrays of cryogenic sensors, has opened the door for innovation in system design and use cases. For example, cryogenic MEG systems are housed in large shielded rooms to provide sufficient space for the system dewar. Here, we investigate the performance of OPM recordings inside of a cylindrical shield with a 1x2 m2 footprint. The efficacy of shielding was measured in terms of field attenuation and isotropy, and the value of post hoc noise reduction algorithms was also investigated. Localization accuracy was quantified for 104 OPM sensors mounted on a fixed helmet array based on simulations and recordings from a bespoke current dipole phantom. Passive shielding attenuated direct current (DC) and power line (60 Hz) fields by approximately 60 dB, and all other frequencies by 80-90 dB. Post hoc noise reduction provided an additional 5-15 dB attenuation. Substantial field anisotropy remained in the volume encompassing the sensor array. The consistency of the anisotropy over months suggests that a field nulling solution could be readily applied. A current dipole phantom generating source activity at an appropriate magnitude for the human brain generated field fluctuations on the order of 0.5-1 pT. Phantom signals were localized with 3 mm localization accuracy and no significant bias in localization was observed, which is in line with performance for cryogenic and OPM MEG systems. This validation of the performance of a small footprint MEG system opens the door for lower cost MEG installations in terms of raw materials and facility space, as well as mobile imaging systems (e.g., truck-based). Such implementations are relevant for global adoption of MEG outside of highly resourced research and clinical institutions.

biophysics↗

Inference for entomological semi-field experiments: Fitting a mathematical model assessing personal and community protection of vector-control interventions

The effectiveness of vector-control tools is often assessed by experiments as a reduction in mosquito landings using human landing catches (HLCs). However, HLCs alone only quantify a single characteristic and therefore do not provide information on the overall impacts of the intervention product. Using data from a recent semi-field study which used time-stratified HLCs, aspiration of non-landing mosquitoes, and blood feeding, we suggest a Bayesian inference approach for fitting such data to a stochastic model. This model considers both personal protection, through a reduction in biting, and community protection, from mosquito mortality and disarming (prolonged inhibition of blood feeding). Parameter estimates are then used to predict the reduction of vectorial capacity induced by etofenpox-treated clothing, picaridin topical repellents, transfluthrin spatial repellents and metofluthrin spatial repellents, as well as combined interventions for Plasmodium falciparum malaria in Anopleles minimus. Overall, all interventions had both personal and community effects, preventing biting and killing or disarming mosquitoes. This led to large estimated reductions in the vectorial capacity, with substantial impact even at low coverage. As the interventions aged, fewer mosquitoes were killed; however the impact of some interventions changed from killing to disarming mosquitoes. Overall, this inference method allows for additional modes of action, rather than just reduction in biting, to be parameterised and highlights the tools assessed as promising malaria interventions.

systems biology↗