Search bioRxivSearch

Biology subjects

Turner, H. C.

Publications and source records attributed to Turner, H. C..

3 recordsLinked to original sources

DNA damage response in peripheral mouse blood leukocytes in vivo after variable, low-dose rate exposure

Environmental contamination and ingestion of the radionuclide Cesium-137 (137Cs) is a large concern in fallout from a nuclear reactor accident and improvised nuclear device and highlights the need to develop biological assays for low dose rate, internal emitter radiation. To mimic low dose rates attributable to fallout, we have developed a VAriable Dose-rate External 137Cs irradiatoR (VADER), which can provide arbitrarily varying and progressive low dose rate irradiations in the range of 1.2 to 0.1 Gy/day, while circumventing the complexities of dealing with radioactively-contaminated biomaterials. We investigated the kinetics of mouse peripheral leukocytes DNA damage response in vivo after variable, low-dose rate 137Cs exposure. C57BL/6 mice were placed in the VADER over 7 days with total accumulated dose up to 2.7 Gy. Peripheral blood response including the leukocytes depletion, apoptosis signal protein p53 and DNA repair biomarker {gamma}-H2AX were measured. The results illustrated that blood leukocyte count had significantly dropped by days 7. P53 levels peaked at day 2 (total dose=0.91Gy) and then declined whereas {gamma}-H2AX yields generally increased with accumulated dose and peaked at day 5 (total dose=2.08Gy). ROC curve analysis for {gamma}-H2AX provided a good discrimination of accumulated dose < 2 Gy and [&ge;] 2 Gy, highlighting the potential of {gamma}-H2AX as a biomarker dosimetry in a protracted, environmental exposure scenario.

cell biology

New High Throughput Approaches to Detect Partial-body and Neutron Exposures on an Individual Basis

Biodosimetry-based discrimination between homogeneous total-body photon exposure and complex irradiation scenarios (partial-body shielding and/or neutron + photon mixtures) can improve treatment decisions after mass-casualty radiation-related incidents. Our study objective was to use high-throughput biomarkers to: a) detect partial-body and/or neutron exposure on an individual basis, and b) estimate separately the photon and neutron doses in a mixed exposure. We developed a novel approach, where metrics related to the shapes of micronuclei distributions per binucleated cell in ex-vivo irradiated human lymphocytes (variance/mean, kurtosis, skewness, etc.) served as predictors in machine learning or parametric analyses of the following scenarios: (A) Homogeneous gamma-irradiation, mimicking total-body exposures, vs. mixtures of irradiated blood with unirradiated blood, mimicking partial-body exposures. (B) X rays vs. various neutron + photon mixtures. Classification of samples as homogeneously vs. heterogeneously irradiated (scenario A) achieved a receiver operating characteristic curve area (AUROC) of 0.931 (uncertainty range of 0.903-0.951), and R2 for actual vs. reconstructed mean dose was 0.87. Detection of samples with [&ge;]10% neutron contribution (scenario B) achieved AUROC of 0.916 (0.893-0.943), and R2 for reconstructing photon-equivalent dose was 0.77. These encouraging findings demonstrate a proof-of-principle for the proposed approach of analyzing micronuclei/cell distributions to detect clinically-relevant complex radiation exposure scenarios.

biophysics

Development of a high-throughput γ-H2AX assay based on imaging flow cytometry

BackgroundMeasurement of {gamma}-H2AX foci formation in cells provides a sensitive and reliable method for quantitation of the radiation-induced DNA damage response. The objective of the present study was to develop a rapid, high-throughput {gamma}-H2AX assay based on imaging flow cytometry (IFC) using the ImageStream(R)X Mk II (ISX MKII) platform to evaluate DNA double strand break (DSB) repair kinetics in human peripheral blood cells after exposure to ionizing irradiation.\n\nMethodsThe {gamma}-H2AX protocol was optimized for small volumes (100 {micro}l) of blood in Matrix 96-tube format and blood cell lymphocytes were identified and captured by ISX INSPIRE software and analyzed by Data Exploration and Analysis Software.\n\nResultsPresented here are: 1) dose response curves based on {gamma}-H2AX fluorescence intensity and foci number, 2) measurements of DNA repair kinetics up to 24 h after exposure to 4 Gy {gamma} rays and, 3) a mathematical approach for modeling DNA DSB rejoining kinetics using two key parameters a) rate of {gamma}-H2AX decay, and b) yield of residual unrepaired breaks.\n\nConclusionsThe results indicate that the IFC-based {gamma}-H2AX protocol may provide a practical, high-throughput and inexpensive platform for measurements of individual global DSB repair capacity and facilitate the prediction of precision medicine concepts.

cell biology